4
Performance
Rated net power
1
1.2kW @ 48V or 0.96kW @ 24V
Output voltage regulation
to ETS 300-132-2
Rated current
25A @ 48V or 40A @ 24V
Emissions
Water vapour in warm exhaust air
2
Fuel
Fuel type
Hydrogen gas
Fuel pressure
500mbar.g – 700mbar.g
Fuel consumption
Less than 60g per kWh
3
Fuel storage
External storage available separately
Compatible with reformer technology or compressed
hydrogen gas
Fuel composition
99.9% gaseous hydrogen or better
4
Operations and
maintenance
User interface
Options available
5
Start-up time
Less than 10s
Automatic start/stop
Operation governed by factory configurable time,
voltage and current levels in ‘Run’ state. Level set to suit
application battery and load.
6
Manual start/stop
Interface connections provided for ‘Enable/Reset’ and
‘Run’ switch or signal. Accessory switches available.
IP rating
IP20
Certification
Health monitoring
Certification
Options available
7
CE, FCC
Physical
Mass
~10kg
Max dimensions
225mm (W) × 300mm (H) × 550mm (D)
Connections, gas
G1/8 parallel BSP threaded port with face seal, female
Connections, electrical
Power leads 2 × 8AWG (8mm
2
) 1 × Positive cable,
1 × Negative/earth cable, 1 × CAN hi/low/gnd,
1 × LED driver, 1 × FCM Run input, 1 × FCM Enable input
Normal operating
conditions
Altitude
0 – 4000m
8
Operating ambient
temperature range
+5°C to +40°C
Relative humidity
10% to 90%
9
Storage temperature
-40°C to +70°C
1 Hybrid battery provides power for start-up, shut-down and during performance
optimisation cycles.
2 No production of CO, CO
2
or NO
x
. Contains safety permitted trace levels of hydrogen.
3 Achieved at 25°C, beginning of life.
4 According to quality characteristics of Type 1, Grade E and Category 3 hydrogen fuel
specified in BS ISO 14687-3:2014(E).
5 CAN interface can be provided.
6 Typically hybridised with external battery allowing higher combined peak power.
Available load power reduced during battery charge. Multiple units may be operated
in parallel to increase power.
7 Options available for continuous health monitoring and predictive maintenance
scheduling for high system availability.
8 Rated power to 1500m. Power de-rate commences above 1500m.
9 Rated power from 30%. Power de-rate commences below 30%.
Product specification