background image

SBSC11Q Four channel SLA Battery Charger

Operator Manual

 6 Display Brightness

The equipment has the facility to increase or decrease the intensity of each display from dim 
to extremely bright. The following procedure has to be followed to perform this operation.

Ensure the the channel to be changed is not in RUN mode.

Using a small non metallic probe smaller than 2.0mm insert this into the small hole 
between the START and STOP buttons, about 10mm of travel will take place before an 
obstruction is met, apply a small amount of force to operate the internal switch, while 
pressed the display will appear to freeze, this is normal.

Keep the pressure applied until the display shows “FUNC”, (about 5 seconds) at this 
point release the pressure.

The display will then show “

CLV

”.

Press the FUNC button two times so the the display goes from “

CLV

” to “

CLA

” to 

DSP

”.

With the display showing “

DSP

” press the START button.

The display will show “

XXX

”.

Use the START button and STOP button to either increase or decrease the display 
brightness.

Once the correct brightness has been achieved press the FUNC button to store the 
setting.

The display will then show “

CLV

” again.

Press the STOP button to return to normal operation mode.

This procedure has to be performed individually on each channel.

Doc: DWG1057-09-R2 SBSC11Q Operators manual.odt

Page 10 of 18

Copyright Material of Intelligent Charging Limited © 2018

Printed On : 17/07/19

Summary of Contents for SBSC11Q

Page 1: ...nnel SLA Battery Charger Operator Manual Doc DWG1057 09 R2 SBSC11Q Operators manual odt Page 1 of 18 Copyright Material of Intelligent Charging Limited 2018 Printed On 17 07 19 SBSC11Q BATTERY CHARGER OPERATORS MANUAL ...

Page 2: ... Brightness 10 7 Performing calibration 11 7 1 Equipment Required 11 7 2 Calibration Equipment Connection 11 7 3 Check Procedure 11 7 4 Calibration Adjustment 12 7 4 1 Voltage Adjustment 12 7 4 2 Current Adjustment 13 8 Error Conditions 14 9 Specifications 15 10 General Arrangement 16 11 Product Warranty 17 Doc DWG1057 09 R2 SBSC11Q Operators manual odt Page 2 of 18 Copyright Material of Intellige...

Page 3: ...Manual Revision History Rev Date Description 0 22 08 2011 First write 1 12 09 2011 Proof read 2 21 07 2015 Formatting changes Doc DWG1057 09 R2 SBSC11Q Operators manual odt Page 3 of 18 Copyright Material of Intelligent Charging Limited 2018 Printed On 17 07 19 ...

Page 4: ...error condition if START is pressed while battery reverse connection is made The unit detects non battery connection and will show an error if less than 0 8V is detected at the battery terminals The unit will automatically perform a desulphation charge if a battery connected exhibits a terminal voltage less than 9 0V Field calibration possible no need to return the unit back to factory for calibra...

Page 5: ...tors manual odt Page 5 of 18 Copyright Material of Intelligent Charging Limited 2018 Printed On 17 07 19 10A ERR SBSC11Q POWER START STOP OUTPUT 1 RUN DSUL 10A 10A 10A Press To Reset Press To Reset Press To Reset Press To Reset VOLTS AMPS TIME TRIC ERR START STOP OUTPUT 2 RUN DSUL VOLTS AMPS TIME TRIC ERR START STOP OUTPUT 3 RUN DSUL VOLTS AMPS TIME TRIC ERR START STOP OUTPUT 4 RUN DSUL VOLTS AMPS...

Page 6: ...When illuminated the display will show the error number 8 DSUL Indicator This indicator will illuminate if the charger is working in desulphation mode 9 TRICKLE Indicator This indicator will illuminate when the charger is in trickle charge mode 10 RUN Indicator This indicator will illuminate when the charger is operating if the other three indicators are extinguished then the charger is operating ...

Page 7: ...ROGRESS AS ARCING CAN OCCUR CAUSING AN EXPLOSION FROM GASSES VENTING FROM BATTERIES BEING PROCESSED THE BATTERY SHOULD ALWAYS BE ISOLATED FROM ANY EQUIPMENT BEFORE BEING CONNECTED Stray ground loops between the attached equipment and the Battery Charger could cause catastrophic damage to the unit and the attached equipment Provided with the unit is two sets of leads One set terminated with 8mm Rin...

Page 8: ...rices and availability Doc DWG1057 09 R2 SBSC11Q Operators manual odt Page 8 of 18 Copyright Material of Intelligent Charging Limited 2018 Printed On 17 07 19 SBSC11 BATTERY SBSC11 BATTERY SBSC11 BATTERY SBSC11 BATTERY 10A ERR SBSC11Q POWER START STOP OUTPUT 1 RUN DSUL 10A 10A 10A Press To Reset Press To Reset Press To Reset Press To Reset VOLTS AMPS TIME TRIC ERR START STOP OUTPUT 2 RUN DSUL VOLT...

Page 9: ...y terminal voltage of 13 74V During the trickle charge stage the TRICKLE indicator will be on continuously If the battery terminal voltage is below 9 0V the charger will automatically go into desulphation charge mode It will float charge the battery at 13 74V until the charge current stabilises at 20mA whereby the charge will then switch into normal RUN mode Note this process may take several days...

Page 10: ...pear to freeze this is normal Keep the pressure applied until the display shows FUNC about 5 seconds at this point release the pressure The display will then show CLV Press the FUNC button two times so the the display goes from CLV to CLA to DSP With the display showing DSP press the START button The display will show XXX Use the START button and STOP button to either increase or decrease the disp...

Page 11: ...per year the following calibration procedure should be applied Connect a good quality 12 0V battery to the Battery Charger Measure battery voltage and verify the Battery Charger display is within tolerance Doc DWG1057 09 R2 SBSC11Q Operators manual odt Page 11 of 18 Copyright Material of Intelligent Charging Limited 2018 Printed On 17 07 19 200m 2 20 200 1000 V d c 700 200 20 200m V a c 200u 2m 20...

Page 12: ...bration parameters are channel independent so the adjustment must be made on each channel individually 7 4 1 Voltage Adjustment Ensure the the channel to be calibrated is not in RUN mode Using a small non metallic probe smaller than 2 0mm insert this into the small hole between the START and STOP buttons about 10mm of travel will take place before an obstruction is met apply a small amount of forc...

Page 13: ... the display shows FUNC about 5 seconds at this point release the pressure The display will then show CLV Press the FUNC button so that the display shows CLA Press START button At this point the charger will set a charge of approximately 5 0 amps into the connected battery Use the START and STOP buttons to either increase or decrease the display current to set to the same or as near as what is dis...

Page 14: ...ector has been plugged into the charger E02 No Amps Reason The charger cannot seem to drive any current into the battery This is usually because the battery being disconnected during a charge or an internal fault Fix Do not disconnect the battery during a charge cycle Always press STOP before disconnecting the battery If this occurs each time START is pressed then it is an indication of an interna...

Page 15: ... condensing Altitude 0 to 3000 Metres IP rating IP22 Charge Specifications per channel Max Output Volts Max Output Amps Max Output Watts 16 0V 9 0A 130W Accuracy Voltage 0 1V Current 0 05A Weight 12Kg Size 373mm Wide 245mm Height 219mm Depth All specifications are subject to change Doc DWG1057 09 R2 SBSC11Q Operators manual odt Page 15 of 18 Copyright Material of Intelligent Charging Limited 2018 ...

Page 16: ...ISS OF COLOUR METRIC THIRD ANGLE PROJECTION CHANGE DESCRIPTION DATE ISS CJF GC 28 06 2011 DWG1057 00 1 1 1 NA NA NA SBSC11Q GENERAL ARRANGEMENT First Drawn SERIAL No INTELLIGENT CHARGING from Controlled Access Storage Cabinets Ltd Ford House Dewing Road Rackheath Ind Est Norwich Norfolk NR13 6PS ENGLAND TEL 44 1603 722770 FAX 44 1603 722771 MAIL sales casc ltd com CHARGING INTELLIGENT FROM 373 0 m...

Page 17: ...ly and fully comply with all procedures shown in the literature and product training familiarisation sessions as misuse or failure to follow the instructions may render this warranty void This warranty is not transferable and excludes routine maintenance consumables parts subject to normal wear and tear service maintenance kits and damage caused by misuse or negligence Warranty claims attributable...

Page 18: ...annel SLA Battery Charger Operator Manual This page is intentionally left blank Doc DWG1057 09 R2 SBSC11Q Operators manual odt Page 18 of 18 Copyright Material of Intelligent Charging Limited 2018 Printed On 17 07 19 ...

Reviews: