![Intelligent Charging Limited TS2X020 Operator'S Manual Download Page 7](http://html.mh-extra.com/html/intelligent-charging-limited/ts2x020/ts2x020_operators-manual_2073977007.webp)
T
S2X020 : Twin Channel Battery Charger
Operators Manual
3 Connecting A Battery
For all methods of use of the battery charger the battery to be charged must only be
connected when the charger is either:
Not powered up,
or
Powered up and the RUN lamp extinguished for the appropriate channel.
Care must also be executed in ensuring that the bared ends of the battery leads do not come
in contact with the metalwork of the unit as this may also cause electrical arcing and or
explosion risk.
THE BATTERY SHOULD NEVER BE CONNECTED OR DISCONNECTED FROM THE UNIT
WHEN A CHARGE IS IN PROGRESS AS ARCING CAN OCCUR CAUSING AN
EXPLOSION FROM GASSES VENTING FROM BATTERIES BEING PROCESSED
THE BATTERY SHOULD ALWAYS BE ISOLATED FROM ANY EQUIPMENT BEFORE
BEING CONNECTED
Stray ground loops between the attached equipment and the Battery Charger could cause
catastrophic damage to the unit and the attached equipment.
Provided with the unit are two sets of leads terminated with brass battery clamps.
Always connect the battery leads as shown in the following figure to the unit before
attempting to connect the battery to be charged. Once the leads are connected to the unit
then the battery can be connected.
BATTERY LEAD CONNECTION
Doc: DWG1021-10-R2 TS2X020 Operators manual.odt
Page 7 of 16
Copyright Material of Intelligent Charging Limited © 2015
Printed On : 14/06/17