IA-3178-U2i
23
www.intelligent-appliance.com
Specifications are subject to change without notice
32-ch Relay
USB or RS-232 Controlled
?aaWDT – Get WD2 Count-down value
Description
This command reads the System Communication Watchdog, WD2,
Counter Count-down value and sets its value to the Preset value.
Syntax
?aaWDT<CR>
?
Delimiter character
aa
Hexadecimal address of the device
WDT
Read jumper & led status
<CR>
Carriage Return - End of command
Response
_dd<CR> if the command was valid
_
Delimiter character
dd
Output digits in HEX format
Example
Command: ?00WDT<CR>
Response: _12<CR>
In case that WD2 is Activated!
Response: _20 WD2 ERR<CR>
In case that WD2 is Not Activated!
In this example WD2 Count-down value is 18 Seconds.
NOTE 1:
This command reads the WD2 Counter value. Not the WDT Preset value
that is defined by the “
<CR>” command.
NOTE 2:
In case that WD2 is not operated, this command will yield an error and it
will show WDT predefined value.
NOTE 3:
This command, in addition to reading WD2 Counter value, sets the WD2
Counter value to its Preset value.
NOTE 4:
Each reading might yield a different value as it is depended on the time
elapse since previous reading and presetting.