background image

 

USER MANUAL 

 

MODEL: 

TRB-2V1AD

 

Round

 

table box with

 power, HDMI, VGA, 

3.5mm audio, and RJ45 inputs

 

 

 

 

 

Summary of Contents for TRB-2V1AD

Page 1: ...USER MANUAL MODEL TRB 2V1AD Round table box with power HDMI VGA 3 5mm audio and RJ45 inputs...

Page 2: ......

Page 3: ...HDMI VGA 3 5mm audio and RJ45 inputs 4 4 Installing the TRB 2V1AD 7 4 1 Drilling a Hole in the Table 7 4 2 Mounting the TRB 2V1AD in the Table 8 4 3 Connecting the Cables 10 5 Using the TRB 2V1AD 12 6...

Page 4: ...TRB 2V1AD Round table box with power HDMI VGA 3 5mm audio and RJ45 inputs which is ideal for the following typical applications Boardrooms Conference rooms Training rooms Your TRB 2V1AD is available...

Page 5: ...nce high resolution cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tig...

Page 6: ...and unplug the unit from the wall before installing 2 3 Recycling Products The Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC aims to reduce the amount of WEEE sent for disposal...

Page 7: ...ble access or passive interfaces In addition the TRB 2V1AD includes the following pass through connectors 1 VGA on a 15 pin HD connector 1 HDMI connector 1 stereo audio on a 3 5mm connector 1 Ethernet...

Page 8: ...TRB 2V1AD Overview 5 Figure 1 TRB 2V1AD Round table box with power HDMI VGA 3 5mm audio and RJ45 inputs...

Page 9: ...ng the unit to the table surface one on each side 9 Mounting Butterfly Nuts Tighten to secure the unit to the table surface one on each side 10 Mounting Bracket Slits two sets on each side Insert the...

Page 10: ...ection 4 2 3 Connect the cables see Section 4 3 4 1 Drilling a Hole in the Table To drill an opening in the table 1 Using any standard cup bit drill with a diameter ranging from 92mm to 95mm 3 62in to...

Page 11: ...n the Table To mount the unit follow these steps Step 1 Insert the TRB 2V1AD into the hole cut into the table making sure the outer rim is firm against the surface of the table Step 2 From underneath...

Page 12: ...TRB 2V1AD Installing the TRB 2V1AD 9 Step 3 Tighten the butterfly mounting screws securely upward against the table Step 4 Lock the mounting screws into position with the locking butterfly screws...

Page 13: ...D 4 3 Connecting the Cables Figure 3 illustrates how to connect the cables to the underside of the unit Note that the connecting surface is an integral part of the RTBUS 11 enclosure and cannot be det...

Page 14: ...TRB 2V1AD Installing the TRB 2V1AD 11 We recommend that you use the C AC US AC Power Cord 6ft USA 110V AC to power the unit...

Page 15: ...1AD 5 Using the TRB 2V1AD Once the TRB 2V1AD is installed you can easily customize it to your own needs by plugging in the required AV equipment as illustrated in the example in Figure 4 Figure 4 TRB...

Page 16: ...NG TEMPERATURE 0 to 40 C 32 to 104 F STORAGE TEMPERATURE 40 to 70 C 49 to 158 F HUMIDITY 10 to 90 RHL non condensing POWER SOURCE AC power limits 115V AC 50 60Hz 5A Max FUSE RATING T 6 3A 250V DIMENSI...

Page 17: ...This page is intentionally left blank...

Page 18: ...SAFETY WARNING Disconnect the unit from the power supply before opening and servicing...

Reviews: