background image

 

Safety

 

1. 

The  lighting  fitting  should  be  installed,  repaired  and  maintained  by  a  person  with  the  appropriate 
qualifications. Incorrect installation or tampering carries a risk of electric shock.   

2. 

Installation  of  the  lighting  fitting  must  be  carried  out  in  accordance  with  its  purpose  and  these 
instructions.   

3. 

When installing lamps in an open air, never connect power supply in wet conditions. 

4. 

During installation or maintenance, make sure that the power supply is disconnected. 

5. 

When  connecting  the  lighting  fitting  to  the  power  network  ,  make  sure  that  the  power  supply 
parameters  correspond  to  the  rated  power.  Make  sure  to  connect  the  protective  conductor.  After 
connecting the lighting fitting is energized.   

6. 

Do not touch the device with wet or damp hands.   

7. 

In case of suspicion of damage to the electrical part of the device (ballast, power cord), do not use the 
lighting fitting.  

8. 

The device should be mounted in such a way that enables natural heat dissipation. 

9. 

Periodical maintenance should be done in order to assure proper operations. 

10.

 

The manufacturer does not guarantee proper operation and shall be not responsible for any damage 
or  injury  resulting  from  installation,  repair  or  maintenance  performed  in  contrary  to  the  instructions, 
generally  accepted  principles  of  installation,  occupational  safety  rules,  intended  use  or  when  the 
installation was performed by a person without appropriate permissions. 

 

 

Protection of environment

 

1. 

Cardboard or paper elements of the packaging should sent for recycling paper or deposited of into a 
container for paper waste, while plastic packaging into a container for plastic waste.  

 

2. 

Obsolete  lighting  fitting  must  not  be  disposed  of  as  household  waste  and  should  be  delivered  to  a 
special WEEE collecting point. 

 

 

Guarantee 

 

1.  The guarantee is valid for 12 months from the date of purchase.   
2.  The  guarantee  shall  not  cover  mechanical  damage,  damage  caused  by  improper  installation, 

operation or modifications of the lighting fitting as well as changes occurring due to natural wear and 
tear of the product. 

3.  The manufacturer reserves that it does not take responsibility for the improper operation of the lighting 

fitting  as  a  result  of  interference  in  the  lighting  fitting  construction  carried  out  by  the  user  without 
permission. 

4.  Application of the lighting fitting: streets, roads, etc. 

 

 
 
Handling of obsolete equipment

 

 

Pursuant to the Act of 29 July 2005 on 
waste 

electrical 

and 

electronic 

equipment  and  the  Act  of  24  April 
2009  on  batteries  and  accumulators, 
the  presented  device,  after  use,  due 
to hazardous substances contained  in 
it,  is  subject  to  collection  of  waste 
electrical  and  electronic  equipment. 
Detailed 

information 

on 

WEEE 

collection  can  be  obtained  from 
municipal authorities.

 

 

 
 
 
 
 
 

Intelight Sp. z o.o.

 

8, Rydygiera str.

 

01 -793 Warsaw, Poland

 

 
 

KTM 97334 – Instruction ASTREET LED 20 / 30 / 40 / 50, EN, ver. 08062016

EXTERIOR LAMPS 

ASTREET LED

 

 

 

 

 

 

 

 

 

 

Version: ASTREET LED 

 

INSTALLATION AND OPERATION INSTRUCTIONS 

 

  Power supply 

  Source 

Standard colours 

  Mounting 

  on poles 

  IP 

  rating 

  Insulation 

  class 

  230 VAC / 50Hz 

  LED 

Top - grey RAL 7045 

Bottom - white RAL 9016 

  Ø60 

  IP66 

  I 

 

 

   Versions 

  LED 

  source 

  power 

  Total 
  lamp 

  power 

   Astreet LED 20 

14 W 

18 W 

   Astreet LED 30 

21 W 

27 W 

   Astreet LED 40 

28 W 

36 W 

   Astreet LED 50 

35 W 

45 W 

 

 

  Dimensions and weights, all versions * 

  Length [mm] 

468 

  Width [mm] 

235 

  Height [mm] 

104 

  Weight [kg] 

5,0 

* - without grip

 