Before starting the installation, it is necessary to define the height at which the sensor will be positioned, which can vary
from 1.8 to 2.2 m. If the sensor is installed at a height of less than 1.8 m, the
PET function is compromised.
» Do not install sensors that have microwave technology close to each other.
» The sensitivity of the microwave must be adjusted so that targets, outside the desired detection area,
are not detected and
so that there is no interference between the sensors.
12m
1.8 à 2.2m
12 m
1.8 to 2.2 m
» Adjustment of the sensitivity of the PIR (P. Count) and the microwave must be made according to each environment. In
environments where sunlight falls directly on the sensor lens, the microwave must be adjusted between levels 1 and 3.
MIN
MAX
1
2
3
4
5
MICRO-ONDAS
Ajuste o Micro-ondas
entre o nível 1 e 3
.
Microwaves
Adjust the microwave between
level 1 and 3
Min.
Max.
5
1
4
3
2
To attach the sensor to the wall, follow the procedure:
1. Remove the metal support by removing the screw attached to the bottom of the sensor;
2. To install the sensor directly on the wall, use the central holes, indicated on the attaching bracket. To install in the
corner of the wall, use the holes in the positions indicated on the side of the attaching bracket.
Furos centrais
Furos centrais
Furos
laterais
Furos
laterais
MONTADO NA PAREDE
MONTADO NO CANTO DA PAREDE
Mounted on the corner of the wall
Side holes
Side holes
Wall mounted
Center holes
Center holes