Intelbras IVP 2000 SF User Manual Download Page 9

9

7.3.  Low battery sensor

The IVP 2000 SF sensor controls the battery level. If it is critical (7V), it will send the information to the control panel. If low 
battery signaling is enabled in the control unit, the information is sent during the trigger.

Note:

 

consult the control panel manual to verify compatibility with low battery signaling and supervision.

8. Homologation

0577-09-0160

This equipment operates on a secondary basis, that is, it is not entitled to protection against harmful interference, even 
from stations of the same type, and may not cause interference to systems operating on a primary basis. This is a product 
approved by Anatel, the approval number can be found on the product label, for queries go to the website: 

sistemas.

anatel.gov.br/sch.

Summary of Contents for IVP 2000 SF

Page 1: ...User manual IVP 2000 SF...

Page 2: ...ssive infrared sensor IVP 2000 SF was developed by Intelbras with 100 digital technology This sensor features SMD technology offers efficient detection with reduced risk of false triggers and has auto...

Page 3: ...r conditioners and heaters fans refrigera tors and ovens Do not expose the sensor directly or to sunlight reflections For the use of the articulator we recommend that the installation be done by a pro...

Page 4: ...2 0 0 6 5 1 LED adjustment 6 5 2 Sensitivity adjustment of the IVP 2000 SF sensor 6 5 3 IVP 2000 SF sensor operating mode 6 5 4 Low battery sensor 7 6 Test 7 7 Configuring the IVP 2000 SF sensor for...

Page 5: ...sed OOK Frequency 433 92 MHz Baud rate 2 KBps open source 2 Characteristics 2 levels of sensitivity Economy mode of operation Passive infrared with dual element Low battery sensor Ease of installation...

Page 6: ...sor will operate in the test period for 15 minutes so that the installer can make all sensor positio ning adjustments During this period at any motion detection the LED lights up and a trigger is gene...

Page 7: ...g in continuous mode To register the sensor code in the alarm control panel check the procedure in the manual of the used alarm control panel and trigger a trigger by moving in front of the sensor to...

Page 8: ...will work in Economy mode When the sensor triggers while in Economy mode it is necessary to wait a period of two minutes without movement for it to detect again Advantage of Economy mode In environmen...

Page 9: ...l manual to verify compatibility with low battery signaling and supervision 8 Homologation 0577 09 0160 This equipment operates on a secondary basis that is it is not entitled to protection against ha...

Page 10: ...parties foreign to the manufacturer b if the damage to the product arises from accidents disasters agents of nature lightning floods landslides etc humidity voltage in the electrical network excess v...

Page 11: ...uporte intelbras com br Customer Service 0800 7042767 Where to buy Who installs it 0800 7245115 Produced by Intelbras S A Ind stria de Telecomunica o Eletr nica Brasileira Rodovia BR 459 km 124 1325 D...