2. Product
Lenses
Top fixing screw
Response time
adjustment
Cover lock screw
Beam alignment
display
Fixing screw
with clamp
Terminal block
Threads
Indicator
LEDs
Interior fixing
screw
Receiver
Adjustment
vertical
Tamper
Horizontal
adjustment
Reception level
3. Installing the sensors
The IVA 3070X and 3110X sensors can be installed at a distance of 100 m from the panel, however, the ohmic characte-
ristics of the cable being used must be taken into account as well as the characteristics of the panel area.
Longitudinal protection distance and lateral protection distance
No fog
With fog
Model
Longitudinal protection
distance
Side protection distance
Longitudinal protection
distance
Side protection distance
IVA 3070 X
70 m
5 m
35 m
2.5 m
IVA 3110 X
110 m
8 m
55 m
4 m
Note:
this sensor has high immunity to false triggering with fog, however, triggering can occur depending on the density
of the fog or fog in the environment.
If the longitudinal protection distance is different from that shown in the table above, use the formula below to calculate
the side protection distance.
DPL = Side protection distance
DP = Longitudinal protection distance
DPL = SD × 0.072