background image

 

 

 

 

Intel® Storage Server 
SSR212MC2  

Technical Product Specification  

 

 

 

Revision 1.2

EPSD Technical Support & Services Group

Summary of Contents for SSR212MC2 - Storage Server Hard Drive Array

Page 1: ...Intel Storage Server SSR212MC2 Technical Product Specification Revision 1 2 EPSD Technical Support Services Group ...

Page 2: ...vision History Date Revision Number Modifications April 24 2007 1 0 Release copy May 23 2007 1 1 Corrected Battery Backup product code clarified expansion slots corrected RAID sku product code nomenclature July 10 2007 1 2 Added AC Power consumption tables to section 2 1 ...

Page 3: ...sponsibility whatsoever for conflicts or incompatibilities arising from future changes to them The Intel Storage Server SSR212MC2 may contain design defects or errors known as errata that may cause the product to deviate from published specifications Current characterized errata are available on request Intel system boards contain a number of high density VLSI and power delivery components that ne...

Page 4: ...tialization 12 Expander Port Configuration 13 1 7 Chassis Dimensions and Weight 14 1 8 Back Panel I O Ports and Features 15 1 9 Front Panel and HDD Bays 16 1 9 1 Front Rear Panel Controls and Indicators 17 1 10 Fan Monitoring 18 1 10 Rack and Cabinet Mounting Options 18 2 Power Sub System 19 2 1 Power Supply Enclosure 19 2 1 1 Hot Swapping Power Modules 20 2 1 2 Power Supply Outputs 20 3 System Co...

Page 5: ...xternal Rear I O Panel Connectors 31 6 3 External Front Panel Connectors 31 7 Regulatory Information 32 6 1 Product Regulation Requirements 32 7 1 1 Product Safety Compliance 32 7 1 2 Product EMC Compliance Class A Compliance 32 7 1 3 Certifications Registrations Declarations 33 7 1 4 Component Regulation Requirement 33 7 1 5 Product Ecology Requirements 34 7 2 Restriction of Hazardous Substances ...

Page 6: ...12MC2 Block Diagram 6 Figure 4 System Components 7 Figure 5 Vitesse VSC410 Block Diagram 11 Figure 6 PMC PM8388 Block Diagram 12 Figure 7 Back Panel I O Ports 15 Figure 8 Chassis Front and Rear 16 Figure 9 Front Panel 17 Figure 10 Rack Mounting 18 Figure 11 Power Supply Module 20 Figure 12 Cooling Module 22 Figure 13 Drive Carrier Removal 23 Figure 14 Hard Disk Drive Bays 25 Figure 15 Hard Drive C...

Page 7: ...utton Functions 17 Table 8 Front LED Indicator Status 17 Table 9 AC Input Current 19 Table 10 AC Power Consumption with SATA drives 19 Table 11 AC Power Consumption with SAS drives 19 Table 12 Enclosure DC Output Summary 20 Table 13 Power Supply LED Indicators 21 Table 14 Drive Numbering 24 Table 15 SAS 4i Host Connector 28 Table 16 EM Card PWR_A Connector 29 Table 17 EM Card PWR_B Connector 29 Ta...

Page 8: ...List of Tables Intel Storage Server SSR212MC2 TPS viii Revision 1 2 This page intentionally left blank ...

Page 9: ...ontroller SRCSAS144E product codes SSR212MC2R and SSR212MC2 respectively and includes a 2U chassis Intel Server Board S5000PSL with support for either one or two Dual Core 5100 sequence or Quad Core 5300 sequence Intel Xeon processors twelve SATA SAS hard disk drive carriers dual Intel PRO 1000 Network connections and a single 850 W power supply dual redundant 1 1 capable Intel based system boards...

Page 10: ...essors installed Please refer to the SSR212MC2 Configuration Guide for a list of supported processors Memory Capacity Expandable to 32 GB maximum NOTE The Intel Storage Server SSR212MC2 does not ship with memory installed Please refer to the SSR212MC2 Tested Memory List for a list of supported memory Memory Type FBDIMM DIMM Slots Eight Enclosure Controller On board Vitesse VSC410 micro controller ...

Page 11: ...stem 40 degrees Celsius to 70 degrees Celsius Relative Humidity Non operating 90 35 degrees Celsius non condensing Acoustics 7 0 BA rack mount in an idle state in an normal office environment 23 degrees Celsius Electrostatic Discharge 15 KV per Intel test specification Safety Compliance Argentina IRAM Canada UL60950 CSA 60950 UL and cUL China GB4943 CNCA Certification Europe CE Mark EN60950 compli...

Page 12: ...ature Summary Intel Storage Server SSR212MC2 4 Revision 1 2 1 1 System Components A block diagram of the SSR212MC2R sku with RAID card is shown below Figure 2 Intel Storage Server SSR212MC2R Block Diagram ...

Page 13: ... LED 10 x PRESENT 10 x TACHO 5 x PWM 12 12 Temp Sensor EEPROM High Power Connector 10 x FAN 5 banks individually hot plugable Memory 12V Z I F Control SSI 12V 5V 5V Remote Ops serial ICE RS232 USB 2 0 LEDs Ops I2 C Master I2 C Slave I2 C Master SES 2 3 SAS EXPANDER 4 Lane 4 LANE SES 4 Lane 4 Lane I2 C Slave IPMI Header Pass Thru Cable SMBus or BMC Power Button Reset Button Intrusion Switch Rear ID...

Page 14: ...Feature Summary Intel Storage Server SSR212MC2 6 Revision 1 2 The components included with the storage system are diagrammed below Figure 4 System Components ...

Page 15: ...deo Controller w 16MB of video DDR SDRAM memory Connectors Headers Stacked PS 2 ports for keyboard and mouse Stacked video DB9 serial port A connector Two RJ45 2xUSB connectors for 10 100 1000 Mb and USB 2 0 support One USB 2x5 pin header which supports two USB ports One USB port Type A connector One DH10 serial port B header Two SATA connectors and four SAS connectors One ATA100 40 pin connector ...

Page 16: ...external SFF8470 connector IOP Intel 80333 I O processor which performs hardware exclusive OR XOR assistance Card dimensions 7 71 inches by 2 525 inches Serial port 4 pin serial debug requires transceiver Compatible devices 32 physical devices 64 logical drive mixed capacity mixed SATA and SAS not recommended Firmware 4 Mbit in flash ROM Please refer to the Intel RAID Controller SRCSAS144E Hardwar...

Page 17: ...cal management peripherals 8 Mbit of Serial Flash Memory for code storage Drive fault and presence detection Support for up to 10 hot swap fan modules with fault and presence detection Closed loop thermal control through temperature monitoring and fan speed control no dependency on host system BIOS and software PSU status monitoring audible alarm control EEPROM for FRU data storage JTAG test debug...

Page 18: ...ted RISC processor for SAS SMP functions and SES support All target ports support spin up control and the STP bridge function allowing either a SAS or SATA target device to be attached The PM8388 device supports table routing of up to 1024 entries direct routing and subtractive routing methods The non blocking crossbar in the data path allows any port to any port connections including arbitrary wi...

Page 19: ...is able to address 4 banks of Flash or SRAM of 2 Mbytes each The memory banks can be 8 bit or 16 bit wide The Flash Memory Interface provides a way to configure device features during the reset sequence After system reset the processor loads an 8 Kbyte initialization string This initialization string contains information such as the SAS base address of the PM8388 device identification of a subtrac...

Page 20: ...ts are used for host connection to a SAS HBA in the server sub system Four other ports are reserved for expansion purpose and are routed to a dedicated SAS 4i connector on the expander card The remaining four ports are not used and must be disabled Table 5 SXP Port Configuration PM8388 Connects To PM8388 Connects To Port0 Drive 1 Port12 Expansion 1 Port1 Drive 0 Port13 Drive 7 Port2 Drive 2 Port14...

Page 21: ...dth across body of chassis 443 4 mm 17 46 inches Depth from rack posts to rear of PCI bulkhead 666 mm 26 22 inches Depth from rack posts to extremity of chassis 707 mm 27 83 inches Depth from flange to furthest extremity at Front Panel cover 30 mm 1 18 inches Weight Chassis as shipped 0 drives Chassis fully configured 12 drives Shipping container 20 kilogram 30 kilogram 3 2 kilogram 44 pounds 66 p...

Page 22: ... Storage Server SSR212MC2 14 Revision 1 2 1 8 Back Panel I O Ports and Features The Input Output I O connectors are integrated to the back panel The figure below shows the Back Panel I O ports Figure 7 Back Panel I O Ports ...

Page 23: ...Intel Storage Server SSR212MC2 Feature Summary Revision 1 2 15 1 9 Front Panel and HDD Bays Figure 8 Chassis Front and Rear ...

Page 24: ...system identification LED NMI rear mounted Non Maskable Interrupt Table 8 Front LED Indicator Status Power Active Continuous green light indicates the system has power applied to it No light indicates the system does not have power applied to it other than 5 V standby power Unit Fault Continuous amber light indicates fault present ID LED The blue system identification LED is used to help identify ...

Page 25: ... 19 in 483 mm wide by up to 36 in 914 mm deep and are compliant to the SSI Server Rack specification and EIA 310 D A set of Rack Mounting Rails are provided and will accommodate either square or round hole rack mounting methods When mounting the system into a cabinet the front mount brackets are attached to the front of the chassis and a set of rear support brackets are attached to the back of the...

Page 26: ...uration w one power supply module 8 GB memory single 5120 CPU 12x Seagate 750GB Barracuda ES drives AC Input Voltage Freq AC Power Consumption CPU and Ethernet ports all idle 110V 60Hz nominal 465 W Heavy I O 80 CPU utilization max Ethernet traffic 110V 60Hz nominal 520 W CPU and Ethernet ports all idle 230V 50Hz nominal 450 W Heavy I O 80 CPU utilization max Ethernet traffic 230V 50Hz nominal 505...

Page 27: ...SR212MC2 power supply assembly is capable of supporting hot swapping of power supply modules in a 1 1 configuration 2 1 2 Power Supply Outputs The Storage System SSR212MC2 power system supports one or two 850 W Power Supply module s in a 1 1 redundant configuration The Power Supply Enclosure provides ten DC output rails six 12V rails one 5V rail one 3 3V rail one 5Vsb rail one 12V rail Table 12 En...

Page 28: ...er to indicate that the power supply has failed shutdown due to over current shutdown due to over temperature or is indicating a predictive failure Refer to the following table for conditions of the LED Table 13 Power Supply LED Indicators POWER SUPPLY CONDITION Power Supply LED No AC power to all PSU OFF No AC power to this PSU only AMBER AC present Only Standby Outputs On BLINK GREEN Power suppl...

Page 29: ...for ease of maintenance The Power Supply Module contains two fans for cooling 3 1 Fan Control Each fan within the module is capable of supporting multiple speeds At normal room ambient of 23 degrees Celsius C the fans will run at slow speed for best acoustic performance If the external temperature of the system increases the backplane fan control circuitry will increase fan speed to compensate for...

Page 30: ...vision 1 2 4 Chassis Bays The Storage System SSR212MC2 chassis provides twelve hard drive bays at the front of the chassis All hard drive bays may be populated with a carrier mounted 3 5 inch SATA or SAS hard disk drive Figure 13 Drive Carrier Removal ...

Page 31: ...ken before hot swapping while the system is functioning under OS Application control i e your OS Application must support hot swap or data may be lost NOTE All drive bays 1 thru 12 are controlled by the single Intel RAID Controller SRCSAS144E Table 14 Drive Numbering 1 2 3 4 5 6 7 8 9 10 11 12 1 HDD labels are provided in your Storage System SSR212MC2 shipping container to number the drives 1 thru...

Page 32: ... and lock the carrier in place and also has a safety locking mechanism to aid in the prevention of accidental removal of a drive After the drive is inserted and latched the locking feature is enabled by rotating the locking mechanism using the provided Torx or star bit tool such that the latch can not be depressed to remove the drive To remove the drive turn the locking mechanism until the latch c...

Page 33: ...Intel Storage Server SSR212MC2 Chassis Bays Revision 1 2 25 Figure 15 Hard Drive Carrier Assembly ...

Page 34: ...S or SATA drives 5 1 SAS One or two 2 5 SAS drives can be mounted in the internal Boot Drive Enclosure and used to store the Operating System and Applications 5 2 SATA One or two 2 5 SATA drives can be mounted in the internal Boot Drive Enclosure and used to store the Operating System and Applications NOTE Please reference the latest revision of the SSR212MC2 Tested Hardware and Operating System L...

Page 35: ... SAS 4i 1 32 way vertical SMD Table 15 SAS 4i Host Connector Pin Signal Name Pin Signal Name 1 GND 17 N C 2 Host0_PORT3 18 N C 3 Host0_PORT2 19 N C 4 GND 20 GND 5 Host0_PORT1 21 Host2_PORT3 6 Host0_PORT0 22 Host2_PORT2 7 GND 23 GND 8 Host1_PORT3 24 Host2_PORT1 9 Host1_PORT2 25 Host2_PORT0 10 GND 26 GND 11 Host1_PORT1 27 Host3_PORT3 12 Host1_PORT0 28 Host3_PORT2 13 GND 29 GND 14 N C 30 Host3_PORT1 ...

Page 36: ...ND 8 GND 9 5V 10 5V Table 17 EM Card PWR_B Connector Pin Signal Name Pin Signal Name 1 12V6 2 12V6 3 GND 4 12V6 5 GND 6 GND 7 GND 8 GND 9 5V 10 5V 6 1 2 2 Front Panel Cable Molex 51296 1893 ZIF socket 1 18 way 0 5mm pitch right angle SMD Table 18 Front Panel Cable Pin Signal Name Description 1 LED_ID ID LED Cathode terminal 2 LED_FAIL FAIL LED Cathode terminal 3 GND Ground 4 BTN_ID ID Switch termi...

Page 37: ...t Drive Enclosure If this header is to be used for an internal boot DOM etc the Front Panel mini USB cable must be removed from the header thus disabling the Front Panel mini USB port Samtec TSW 105 07 T S 004 Header 5 way 0 1 pitch vertical Pin 4 keyed PIH Table 19 USB 2 0 Connector Pin Signal Name 1 USB_PWR 2 USB_D 3 USB_D 5 GND NOTE the Boot Drive Enclosure must be removed to access the USB hea...

Page 38: ...e following I O ports available Two RJ 45 LAN connectors One DB 9 Serial Port One Stacked PS2 port for keyboard mouse One DB15 video connector Four USB 2 0 ports 6 3 External Front Panel Connectors The Storage System SSR212MC2 provides a mini USB port on the front panel NOTE A USB adapter is included in the shipping box to convert the USB Mini 5 pin port to a standard USB A type port ...

Page 39: ...77 92 License Russia Belarus License Belarus Ukraine License Ukraine CE Low Voltage Directive 73 23 EEE Europe IRAM Certification Argentina GB4943 CNCA Certification China 7 1 2 Product EMC Compliance Class A Compliance Note Legally the product is required to comply with Class A emission requirements as it is intended for a commercial type market place Intel targets 10db margin to Class A Limits F...

Page 40: ...minimum certifications UL and TUV or VDE All current limiting devices shall have UL and TUV or VDE certifications and shall be suitable rated for the application where the device in its application complies with IEC60950 All lithium batteries shall be UL recognized and battery circuits are to have suitable reverse bias current protection for the application it is used in All printed wiring boards ...

Page 41: ... ABS Packaging materials may not contain more than 100 ppm total of lead cadmium chromium or mercury If sold as a retail product packaging materials must be marked with applicable recycling logos for Europe green dot and Japan Eco marks Product documentation shall incorporate all safety required information to conform to certifiers and regulators and the certifications issued for the product All c...

Page 42: ...s Operating Shock No errors with a half sine wave shock of 2 G with 11 millisecond duration Package Shock Operational after a 24 inch free fall although cosmetic damage may be present chassis weight 30 lbs Electrostatic Discharge ESD 15 Kilovolt KV per Intel Environmental test specification System Cooling Requirement in British Thermal Units BTU per Hour 3600 BTU hour at 850W 8 2 System Environmen...

Page 43: ...mum Integrated Circuit IC junction temperature as specified in the component data sheets CPDs Thermal Shock Specification Non operating 40 degrees celcius to 70 degrees celcius Humidity Specification Non operating 92 Relative Humidity RH at 50 degrees celcius Vibration Specification Non Operating 2 2 Grms 5 500Hz for the unpackaged and 1 09 Grms 5 500Hz for the packaged Shock Specification Non ope...

Page 44: ... individual components within the chassis and does not include hard disk drives Table 22 Component MTBF Numbers Subassembly System in 35 oC ambient air MTBF hours System Board S5000PSL 98 000 850 W Power Supply PDB 84 000 Hot Swap SAS Backplane 1 440 000 Fan Tray Interposer 371 000 Fans 5x 1 000 000 Front Panel board 24 000 000 SRCSAS144E SAS Eight Channel RAID adapter 255 000 Battery Backup Unit ...

Page 45: ... Data Sheet D2D DC to DC dBA Decibel Average DDR Double Data Rate DIMM Dual Inline Memory Module DMA Direct Memory Access DOM Disk On Module ECC Error Correcting Code EEB Entry Level Electronics Bay EEPROM Electrical Erasable Programmable Read Only Memory EMC Electro Magnetic Compatibility EMP Emergency Management Port ESD Electrostatic Discharge FC Fibre Channel FP Front Panel FRB Fault Resilient...

Page 46: ...meter msec Millisecond MTBF Mean Time Between Failure MTTR Mean Time to Repair NIC Network Interface Card OTP Over Temperature Protection OVP Over Voltage Protection PCI Peripheral Component Interconnect PDB Power Distribution Board PFC Power Factor Correction PIO Programmed Input Output PLD Programmable Logic Device PSON Power Supply On PSU Power Supply Unit PWT Processor Wind Tunnel RAID Redunda...

Page 47: ...erver System Infrastructure TQFP Thin Quad Flat Pack TB Terabyte UART Universal Asynchronous Receiver Transmitter µF Micro Farad 1 x 10 6 Farads µS Micro Second 1 x 10 6 Second USB Universal Serial Bus V Volt VA Volt Amp VCCI Voluntary Control Council for Interference VQFP Very Thin Quad Flat Pack VRM Voltage Regulator Module W Watt ...

Reviews: