Intel Server RAID Controller U3-1L (SRCU31L)
7
Quick Start Guide
Intel Server RAID Controller U3-1L Low Profile
Hardware Setup
Hardware Requirements
•
Server/Computer with CD-ROM Drive (not attached to SRCU31L)
•
One available PCI slot (32 bit, 33 MHz recommended)
•
Monitor (display resolution of 800 x 600 or higher recommended)
•
Intel Server RAID Controller U3-1L Low Profile Adapter Card
Installing Intel Server RAID Controller U3-1L Low Profile
into a System
The SRCU31L comes ready to be inserted into the system motherboard. The
Intel Integrated RAID firmware has already been programmed into the flash
memory.
WARNING
SHOCK HAZARDS may be present inside the unit in which this card
is being installed. Disconnect all power cords to the unit before
removal of any covers.
Follow the warnings noted in your computers user or service
manual before installing this board. ONLY after all the covers are
reinstalled should you reattach the power cords and power up the
unit for the software installation and use.
1
Power down the system, disconnect power cord(s) and remove the system
cover.
2
Install the SRCU31L into an available PCI slot. Connect one end of the
SCSI cable to the internal (68 pin) or external (VHDCI) SCSI connector on
the SRCU31L. Connect the other end of the SCSI cable to the SCSI drives
or drive enclosure.
3
Replace the system cover, reconnect power cord(s).
✏
NOTE
SRCU31L will work in a 64 bit slot, however, a 32 bit, 33 MHz PCI slot is
recommended. Consult the system guide for the target server board to
determine an appropriate 32 bit, 33 MHz PCI slot.
✏
NOTE
Ensure that the end of the SCSI bus is properly terminated. Consult the
documentation for the drives or drive enclosure for termination details.