Figure 42. Lifting the PCI Cage Assembly Out of the Enclosure
6. Remove the metal blank filler for the appropriate slot you will be plugging the card
into (the top slot is used for the first installed card).
7. Carefully install the PCI card starting at the top slot of the PCI cage. PCI cards are
keyed so they cannot be installed backwards.
8. To reinstall the PCI cage assembly, line up the tabs at the bulkhead cutouts on the
rear of the enclosure.
9. Carefully lower the assembly and align the PCI cage circuit card with the CPU
server board connector. Press into place.
10. Tighten the two (2) captive screws on the PCI card cage assembly.
11. Depending on the type of card installed, there may be cables that have to be routed.
In the case of a RAID card, you must route the SAS cable through the fan assembly
(where other cables are routed) and connect to the I/O module located just behind
the midplane.