64
Server System SR1630GP / SR1630HGP Service Guide
8. Install the replacement riser connector, if desired. For instructions, see
9. Install the PCIe* Riser assembly into the server system. For instructions, see
“Installing the PCIe* Riser Assembly” on page 62
10. Install the server system cover. For instructions, see
.
11. Plug all peripheral devices and the AC power cable into the server.
Installing a PCIe* Riser Card
1. Observe the safety and ESD precautions at the beginning of this book. See
.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see
4. Disconnect any cables attached to any add-in cards.
5. Remove the PCIe* Riser assembly. For instructions, see
.
6. Remove any add-in cards from the PCIe* Riser connector. For instructions, see
“Removing a PCI Add-in Card” on page 66
7. Use two screws to attach the riser card to the riser assembly. See Figure 53.
Figure 53. Installing Riser Card onto Riser Assembly
8. Install an PCI add-in card if desired. For instructions, see
9. Install the PCIe* Riser assembly into the server system. For instructions, see
“Installing the PCIe* Riser Assembly” on page 62
10. Connect any cables to add-in cards that require them. See your add-in card
documentation for information and add-in card requirements.
11. Re-install the processor air duct. For instructions, see
AF003289
Summary of Contents for SR1630GP - Server System - 0 MB RAM
Page 4: ...iv Intel Server System SR1630GP SR1630HGP Service Guide...
Page 6: ...vi Intel Server System SR1630GP SR1630HGP Service Guide...
Page 12: ...xii Intel Server System SR1630GP SR1630HGP Service Guide...
Page 18: ...xviii Intel Server System SR1630GP SR1630HGP Service Guide...
Page 22: ...xxii Intel Server System SR1630GP SR1630HGP Service Guide...
Page 118: ...96 Intel Server System SR1630GP SR1630HGP Service Guide...
Page 168: ...146 Intel Server System SR1630GP SR1630HGP Service Guide Intel Intel Intel Web UL...
Page 169: ...Intel Server System SR1630GP SR1630HGP Service Guide 147...
Page 170: ...148 Intel Server System SR1630GP SR1630HGP Service Guide ITE ITE 5V...
Page 171: ...Intel Server System SR1630GP SR1630HGP Service Guide 149...
Page 172: ...150 Intel Server System SR1630GP SR1630HGP Service Guide ESD ESD ESD ESD ESD...
Page 173: ...Intel Server System SR1630GP SR1630HGP Service Guide 151 1 2 3...
Page 174: ...152 Intel Server System SR1630GP SR1630HGP Service Guide...
Page 188: ...166 Intel Server System SR1630GP SR1630HGP Service Guide...
Page 192: ...170 Intel Server System SR1630GP SR1630HGP Service Guide...
Page 196: ...174 Intel Server System SR1630GP SR1630HGP Service Guide...