4
Intel® RAID Controller RT3WB080 Hardware User’s Guide
Redundancy and Error Handling
•
In-band and out-of-band SES2.
•
Enclosure management support.
•
Support the internal SATA Sideband signal SFF-8485 (SGPIO) interface.
•
Drive coercion (auto-resizing to match existing disks).
•
Auto-detection of failed drives with transparent rebuild. There must be disk activity
(I/O to the drive) for a missing drive to be marked as failed.
•
Auto-resume on reboot of initialization or rebuild (must be enabled before virtual
disk creation).
•
Smart initialization automatically checks consistency of virtual disks if there are five
or more disks in a RAID 5 array, which optimizes performance by enabling read-
modify-write mode. RAID 5 arrays of only three or four drives use Peer Read mode.
•
Dirty cache LED plus error reporting for cache write to disk.
•
Smart Technology predicts failures of drives and electronic components.
•
Patrol Read checks drives and maps bad sectors.
•
Commands are retried at least four times.
•
Firmware provides best effort to recognize an error and recover if possible.
•
Failures are logged from controller and drive firmware, and SMART monitor.
•
Failures are logged in NVRAM, viewable from OS Event Log, Intel
®
RAID Web
Console 2; CIM, LEDs, and via alarm.
•
Multiple cache options allow configuration-specific performance optimization:
—
Write-back: Faster because it does not wait for the disk but data will be lost if
power is lost.
—
Write-through: Usually slower but ensures data is on the disk.
—
Read Ahead: Predicts next read will be sequential and buffers this data into the
cache.
—
Non-Read Ahead: Always reads from the drive after determining exact location
of each read.
—
Adaptive Read Ahead: Reads ahead and caches data only if doing sequential
reads.
—
I/O setting: Determines whether read operations check the cache before reading
from disks.
✧
Cache I/O: Checks cache first; only reads disk if data is not in the cache.
✧
Direct I/O: Reads data directly from disk (not cache).
•
Redundancy through:
—
Configuration stored in non-volatile RAM and on the drives (COD).
—
Hot-swap support.
—
Optional battery backup for cache memory.
Summary of Contents for RT3WB080
Page 1: ...Intel RAID Controller RT3WB080 Hardware User s Guide Intel Order Number G17210 001...
Page 4: ...iv Intel RAID Controller RT3WB080 Hardware User s Guide...
Page 6: ...vi Intel RAID Controller RT3WB080 Hardware User s Guide...
Page 8: ...viii Intel RAID Controller RT3WB080 Hardware User s Guide...
Page 10: ...x Intel RAID Controller RT3WB080 Hardware User s Guide...
Page 16: ...6 Intel RAID Controller RT3WB080 Hardware User s Guide...
Page 22: ...12 Intel RAID Controller RT3WB080 Hardware User s Guide...
Page 28: ...18 Intel RAID Controller RT3WB080 Hardware User s Guide...
Page 40: ...30 Intel RAID Controller RT3WB080 Hardware User s Guide...