10.4
Power Output Calculations
One of the parameters in the “apply_behavior” command from the Gateway is the output
power level. This level can be adjusted from 0 to 31.5 dBm. To ensure compliance with the
maximum EIRP restrictions defined in the certification grant, these commands must be
scripted
by an authorized installer or system integrator
.
The maximum power level is a function of the antenna gain and the cable/connector losses
as shown in the equation below.
P
out
+ G
ant
– L
cable
< EIRP
limit
The table below shows the maximum power level allowed for the various types of antennas,
including the two recommended in this section.
EIRP Limit (dBm)
Ant Gain (dB)
Cable Loss (dB)
Max Power Level
Cable and Connector detail
36
9
0.5
27.5
1 m of RG-400 (teflon)
R-SMA and TNC connectors
36
9
3.1
30.1
10 m of RG-400 (teflon)
R-SMA and TNC connectors
36
7
1.1
30.1
3 m of RG-400 (teflon)
R-SMA and TNC connectors
36
5.5
0.5
31.0
1 m of RG-400 (teflon)
R-SMA and TNC connectors
36
10
5.2
20.8
16 m of RG-400 (teflon)
R-SMA and TNC connectors