10
Battery Backup Unit Specifications
Table 1. Battery Backup Unit Specifications
Battery Technology
LiON (Lithium ION) 1 cell
Battery Operating Environment
10–45°C ambient temperature
20% to 80% humidity non-condensing
Battery Storage Temperature
Depends on storage time,:< 30 days: 0–50 °C
30–90 days: 0–40 °C ‘; > 90 days: 0–30 °C
Fast Charge Current
500mAH using charge circuitry card
Battery Voltage
Nominal OCV: 3.7 V
Mechanical
2.611 inches x 2.122 inches
Battery Capacity
700 mAH
Memory Technology
DDR2 SDRAM (1.8 V)
Battery Charge Time
Typical: ~3 hours to charge from 1.8V OCV to 3.7V OCV
Completely depleted: 8 hours
Battery Shelf Life
1 year
Battery Operational Life
Intel provides a 1 year warranty on the AXXRSBBU6.
Supported Cache Memory
128 - 512 Mbytes
Memory
DDR2 SDRAM 667 MHz (1.8V), max 40-bit bus width
MTBF (Electrical Components) 2,490,772 hours at 40° C
Smart Battery Monitoring
Temp monitoring via I2C interface. Supports v1.1 “Smart Battery
System Manager”
Auxiliary Power
Ability to detect the presence of an external auxiliary power source.
Circuitry automatically chooses aux power, defers discharge until aux
power is removed or exhausted. Auxpower increases the DRT ratings
Battery Life and Data Retention Time
The Intel utilities display a counter showing the number of times a BBU has been recharged. When
you replace a BBU, you should run the utility program and reset this counter to zero for the new
BBU. Intel recommends that you replace the battery pack on the BBU once a year or after 500
recharging cycles, whichever comes first. The warranty on the battery pack is for one year.
The data retention time is 72 hours (low power) if using the RAM shown below. This rating is
approximate and can vary based on battery load, ambient temperature, and number of discharge
cycles associated with the battery.
•
256 Mb using (3) 64Mx16 DDR2
•
128 Mb using (3) 32Mx16 DDR2