Intel® Server System R2000WF Product Family Technical Product Specification
97
Figure 70. Intel® VROC upgrade key
Table 63. Intel® VROC upgrade key options
NVMe* RAID Major Features
Standard Intel® VROC
(iPC VROCSTANMOD)
Premium Intel® VROC
(iPC VROCPREMMOD)
CPU attached NVMe SSD – high perf.
√
√
Boot on RAID volume
√
√
Third party vendor SSD support
√
√
Intel® RSTe 5.0 RAID 0/1/10
√
√
Intel® RSTe 5.0 RAID 5
-
√
RAID write hole closed (RMFBU replacement)
-
√
Hot plug/ surprise removal
(2.5” SSD form factor only
√
√
Enclosure LED management
√
√
Note
: Intel® VROC Upgrade Keys referenced in
Table 63 are used for PCIe* NVMe* SSDs only. For SATA RAID support, see Section 7.2.
7.4.4
NVMe* Drive Population Rules for Intel® VROC
In order to support NVMe RAID and NVMe Management features, the optional Intel® VROC Key must be
installed on to the server board. With the Intel VROC key installed, specific drive population rules exist and
must be followed for proper support of the NVMe management features.
The backplane can support PCIe interfaces from the onboard OCuLink connectors on the server board,
and/or optional add-in Intel Tri-Mode RAID modules, PCIe Switch cards and Retimer cards. When cabling the
PCIe interfaces from two different PCIe interface sources to the backplane, the cables from each source must
be connected in defined drive sets of four (0,1,2,3) & (4,5,6,7) as shown in the following diagrams.
Note: The use of one or more OCuLink connectors on the server board to the backplane is considered a
single source.