Intel® Server System R2000WF Product Family Technical Product Specification
45
1100W Power Supply
– AC unidirectional wave; 2.6 kV line to ground and 1.3 kV line to line, per EN
55024: 1998/A1: 2001/A2: 2003, EN 61000-4-5: Edition 1.1:2001-04.
1300W Power Supply
– AC Unidirectional wave; 2kV line to ground and 1kV line to line, per EN
55024: 1998/A1: 2001/A2: 2003, EN 61000-4-5: Edition 1.1:2001-04 .
The pass criteria include the following: No unsafe operation is allowed under any condition; all power supply
output voltage levels to stay within proper specification levels; No change in operating state or loss of data
during and after the test profile; No component damage under any condition.
The power supply complies with the limits defined in EN55024: 1998/A1: 2001/A2: 2003 using the IEC
61000-4-5: Edition 1.1:2001-04 test standard and performance criteria B defined in Annex B of CISPR 24.
3.3.14
Power Recovery
The power supply recovers automatically after an AC power failure. AC power failure is defined to be any loss
of AC power that exceeds the dropout criteria.
3.3.15
Voltage Interruptions
The power supply complies with the limits defined in EN55024: 1998/A1: 2001/A2: 2003 using the IEC
61000-4-11: Second Edition: 2004-03 test standard and performance criteria C defined in Annex B of CISPR
24.
3.3.16
Protection Circuits
Protection circuits inside the power supply cause only the power supply’s main outputs to shut down. If the
power supply latches off due to a protection circuit tripping, an AC cycle OFF for 15 seconds and a PSON#
cycle HIGH for one second reset the power supply.
3.3.16.1
Over-Current Protection
The power supply has current limit to prevent the outputs from exceeding the values shown in Table 21. If
the current limits are exceeded, the power supply shuts down and latches off. The latch is cleared by
toggling the PSON# signal or by an AC power interruption. The power supply is not damaged from repeated
power cycling in this condition. 12 VSB is auto-recovered after removing the over current protection limit.
Table 21. Over current protection, 1300 W power supply
Output
VOLTAGE
Input voltage
range
OVER CURRENT LIMITS
OCP DELAY
+12V
180 – 264VAC
132A min / 138A max
50msec min / 200msec max
152A min / 160A max
5msec min / 20msec max
+12V
90 – 140VAC
72A min / 77A max
50msec min / 200msec max
90 – 140VAC
103A min; 107A max
5msec min / 20msec
12VSB
90 – 264VAC
2.5A min; 3.5A max
5msec min / 20msec
Table 22. Over current protection, 1100 W power supply
Output Voltage
Input Voltage Range
Over Current Limits
+12 V
90 – 264 VAC
120 A min/132 A max
Trip delay
50 msec min
12 VSB
90 – 264 VAC
2.5 A min/3.5 A max
3.3.16.2
Over Voltage Protection (OVP)
The power supply over voltage protection is locally sensed. The power supply shuts down and latches off
after an over voltage condition occurs. This latch is cleared by an AC power interruption. The values are
measured at the output of the power supply’s connectors. The voltage never exceeds the maximum levels
Summary of Contents for R2000WF series
Page 2: ...Blank page...