Intel® Server System R2000WF Product Family Technical Product Specification
44
Table 18. AC line surge transient performance
Duration
Surge
Operating AC Voltage
Line Frequency
Performance Criteria
Continuous
10%
Nominal AC Voltages
50/60 Hz
No loss of function or performance
0 to ½ AC cycle
30%
Mid-point of nominal AC Voltages
50/60 Hz
No loss of function or performance
3.3.8
DC Output Specification
The following tables defines the minimum power and current ratings. The power supply 1300W must meet
both static and dynamic voltage regulation requirements for all conditions.
Table 19. Maximum Load Ratings
Parameter
VAC
Min
Max.
Continuous
20sec
Peak
2
10msec
Peak
3,4
100µsec
Peak
Unit
12V main
200-
240VAC
0.0
108
120
130
150
5
A
12V main
100-
127VAC
0.0
62
70
80
NA
A
12Vstby
1
0.0
2.1
2.4
NA
NA
A
3.3.9
Susceptibility Requirements
The power supply meets the following electrical immunity requirements when connected to a cage with an
external EMI filter which meets the criteria defined in the SSI document
EPS Power Supply Specification
. For
further information on Intel standards, please request a copy of the
Intel Environmental Standards
Handbook
.
Table 20. Performance criteria
Level
Description
A
The apparatus continues to operate as intended. No degradation of performance.
B
The apparatus shall continue to operate as intended. No degradation of performance beyond spec limits.
C
Temporary loss of function is allowed provided the function is self-recoverable or can be restored by the operation of the
controls.
3.3.10
Electrostatic Discharge Susceptibility
The power supply complies with the limits defined in EN 55024: 1998/A1: 2001/A2: 2003 using the IEC
61000-4-2: Edition 1.2: 2001-04 test standard and performance criteria B defined in Annex B of CISPR 24.
3.3.11
Fast Transient/Burst
The power supply complies with the limits defined in EN55024: 1998/A1: 2001/A2: 2003 using the IEC
61000-4-4: Second edition: 2004-07 test standard and performance criteria B defined in Annex B of CISPR
24.
3.3.12
Radiated Immunity
The power supply complies with the limits defined in EN55024: 1998/A1: 2001/A2: 2003 using the IEC
61000-4-3: Edition 2.1: 2002-09 test standard and performance criteria A defined in Annex B of CISPR 24.
3.3.13
Surge Immunity
The power supply is tested with the system for immunity to the following for each power supply option: