background image

Intel® Server S2600WF Product Family Configuration Guide 

78 

 

Table 43. Intel® Server System LFRB2312WFTF401 product specifications and configuration requirements 

Intel® Server System LFRB2312WFTF401

 

2U, Intel® Server Board S2600WFTF, 12 x 3.5” HDD or 12 x 2.5” SSD SATA/SAS front mount drives (support for up to 2 NVMe* drives), Intel® Xeon® Silver 4106H processor 

 

iPC 

LFRB2312WFTF401 

MM# 

982903 

UPC 

00735858387323 

EAN 

5032037136235 

MOQ 

 

Product type 

L9 integrated system 

Chassis form factor 

2U rack mount 

Packaged gross wt. 

25.0 kg (55.0 lb) 

Un-packaged net wt. 

17.9 kg (39.5 lb) 

Chassis dimensions 

712 x 439 x 89 mm (L x W x H) 

Package dimensions 

983 x 577 x 260 mm (L x W x H) 

 

Included 

Required Items (sold separately) 

Optional Accessories (sold separately) 

(1) – 2U Chassis with Quick Reference Label affixed to top cover 

(1) – Intel® Server Board S2600WFTF (dual 10GbE LAN) – iPC 

S2600WFTF 

(2) – Intel® Xeon® Silver 4106H processor 

(2) – 16 GB, RDIMM, DDR4, 2666 memory module – iPN J26609-002 

(1) – Intel® Remote Management Module 4 Lite 2 – iPC 

AXXRMM4LITE2

 

(2) – PCIe* riser card brackets. Includes: 

o

 

(2) 3-slot PCIe* riser cards – iPC 

A2UL8RISER2

 

o

 

 (1) 2-slot low profile PCIe* riser card – iPC 

A2UX8X4RISER

 

(12) – 3.5” hot-swap drive bays with drive carriers and blanks. Includes: 

o

 

(1) SAS/NVMe combo backplane – iPC 

F2U12X35S3PH

 

o

 

(12) 3.5” hot-swap drive tool less carriers –  iPC 

FXX35HSCAR2

 

(1) – Storage rack handles set – iPN H98453-001 

(1) – Mini front panel (board only – iPN G28538-xxx) 

(1) – 410 mm front panel cable – iPN H26893-xxx 

(1)- 640 mm front panel USB 2.0 cable – iPN H20005-xxx  

(1) – RFID antenna – iPN H69566-xxx 

(1) – 175 mm backplane I2C cable – iPN H91172-xxx 

(1) – 800 mm mini SAS HD cable – iPC 

AXXCBL800HDHD 

(1) – 875 mm mini SAS HD cable – iPC 

AXXCBL875HDHD

 

(1) – 950 mm mini SAS HD cable – iPC 

AXXCBL950HDHD

 

(1) – 525/675 mm backplane power cable – iPN H82097-xxx 

(1) – Standard 2U air duct – iPN H90554-xxx 

(6) – Hot-swap system fans – iPC 

FR2UFAN60HSW

 

(16) – DIMM slot blanks – iPN G75158-00x 

(2) – 1300W AC power supply module – iPC 

AXX1300TCRPS

 

(2) – AC power cord retention strap assembly – iPN H23961-00x 

(2) – CPU heat sinks – iPC 

FXXCA78X108HS

 

(2) – Standard CPU carrier – iPN H72851-xxx 

(1) – 3x Intel® RAID Maintenance Free Backup unit mounting bracket –  iPN H18238-00x 

(1) – 250 mm fixed mount SSD power cable – iPN J29245-xxx 

Spares for each screw type included 

 

Power cord(s) – See Section 5.6 

 

Rack mount kit – See Section 5.7 

Note: 

By default the front drive bays are 

cabled to onboard SATA only ports. An add-

in SAS card or module is needed to support 

SAS devices. 

 

 

Intel® Ethernet Network Adapter for OCP* 

- See Chapter 5.4 for available options 

 

Intel® 12G SAS RAID module and Intel® 

RAID Maintenance Free Backup unit - See 

Chapter 5.5 for available options 

 

SAS data cables – Depending on the 

location of the SAS data controller, new 

data cables may be necessary. See 

Chapter 4. 

 

PCIe* OCuLink data cables (1 per NVMe* 

drive) - See Chapter 4 

 

SATA upgrade key for Intel® Embedded 

Server Technology 2 RAID 5 support – 

iPC 

RKSATA4R5

 

 

Rear mount hot-swap drive bay accessory 

kit – iPC 

A2UREARHSDK2

 

 

ECC DDR4 memory (RDIMM or LRDIMM) 

 

Storage drives 

See Chapters 5 and 6 for all available 

accessory options. 

 

Summary of Contents for R1000WF Series

Page 1: ...and R2000WF Product Families Intel Server System R1000WF and R2000WF Product Families Intel Server System R2000WFTF Product Family Configuration Guide A reference document to identify available Intel Server building blocks integrated systems accessories and spare parts associated with the Intel Server S2600WF product family Rev 2 0 April 2019 ...

Page 2: ... Blank page ...

Page 3: ...information throughout document Added R2312WFQZS to the section 2U 12 x 3 5 R2312WFxxx SAS SATA Data Cable Guide with No SAS Expander Added R2312WFQZS to the section 2U 12 x 3 5 R2312WTxxx SAS SATA Data Cable Guide with SAS Expander Updated 2U systems have three riser card A2UL8RISER2 included on the configuration Updated product ordering information for RSP3MD088F Updated chipset information for ...

Page 4: ...on 4 4 4 6 1 4 6 2 4 7 1 1 4 7 1 2 and 4 7 3 2 Updated MM for R1208WFTYS R2308WFTZS R2208WF0ZS R2208WFTZS R2208WFQZS R2312WF0NP and R2312WFTZS December 2018 1 6 Updated RAID websites in section 5 5 Updated Table 1 51xx Gold processor memory capacity Updated Table 12 to add for 2 5 NVMe support for R2312WFQZS Removed the support for up to two NVMe drives for R2312WFQZS Updated the note in R2312WFQZ...

Page 5: ...ects or errors known as errata which may cause the product to deviate from published specifications Current characterized errata are available on request Intel disclaims all express and implied warranties including without limitation the implied warranties of merchantability fitness for a particular purpose and non infringement as well as any warranty arising from course of performance course of d...

Page 6: ...tel Server Board S2600WF Product Family Options 43 2 2 Intel Server Chassis Product Family Options 45 3 Server System Configurations 50 3 1 Intel Server System R1000WF Product Family 1U Rack Mount System 51 3 2 Intel Server System R2000WF Product Family 2U Rack Mount System 59 4 SAS SATA NVMe Data Cable Guide 82 4 1 Cable Connector Types 83 4 2 1U 2U Server System SAS SATA NVMe Cable Kits 84 4 2 1...

Page 7: ...igurations Cable Guide with SAS Expander 106 5 1U 2U System Optional Accessories 108 5 1 2U Rear Mount Hot Swap Drive Bay Accessory Kits 108 5 2 1U 2U PCIe Riser Card Accessory Spare FRU Options 109 5 2 1 1U Riser Card Options 109 5 2 2 2U Riser Card Options 110 5 3 2U 8x2 5 Drive Bay Module Options 111 5 4 Intel Ethernet Network Adapters for OCP 113 5 5 Intel RAID Add In Cards Modules and Accesso...

Page 8: ... Chassis R2000WFXXX product specifications and configuration requirements 48 Table 18 Intel Server Chassis R2312WFXXX product specifications and configuration requirements 49 Table 19 Intel Server System R1304WF0YS product specifications and configuration requirements 52 Table 20 Intel Server System R1304WF0YSR product specifications and configuration requirements 53 Table 21 Intel Server System R...

Page 9: ...System LFRB2312WFTF801 product specifications and configuration requirements 76 Table 46 Intel Server System LFRB2312WFTF601 product specifications and configuration requirements 77 Table 47 Intel Server System LFRB2312WFTF401 product specifications and configuration requirements 78 Table 48 Intel Server System R2224WFQZS product specifications and configuration requirements 79 Table 49 Intel Serv...

Page 10: ...t hot swap drive bay accessory kits 108 Table 72 1U riser card option 109 Table 73 2U riser card options 110 Table 74 8x2 5 drive bay module accessory kits 112 Table 75 Intel Ethernet Network Adapters for OCP 114 Table 76 Intel Integrated RAID module RMS3 product family SAS 3 0 12 Gb s 115 Table 77 Intel RAID controller add in cards SAS 3 0 12 Gb s 118 Table 78 Intel RAID accessory options 122 Tab...

Page 11: ...on Intel Server System R2208WFxxx 32 Figure 14 2U 2 5 x 16 drive configuration Intel Server System R2208WFxxx 8 drive accessory kit 32 Figure 15 2U 2 5 x 24 drive configuration Intel Server System R2224WFxxx storage configuration 32 Figure 16 2U System back panel with optional 2 x 2 5 hot swap drive bay 33 Figure 20 Intel Server System R2000WFTF feature set identification 35 Figure 21 2U 2 5 x 8 d...

Page 12: ...pander port mapping 107 Figure 34 2U rear mount hot swap drive bay accessory 108 Figure 35 R2208WF based system with front I O module bay assembly 111 Figure 36 2U 2 5 drive identification for each drive bay 111 Figure 37 Intel Ethernet Network Adapter for OCP installation 113 ...

Page 13: ...duct family Figure 1 Intel Server S2600WF product family overview Intel Server Board S2600WF Family Intel Server Chassis R1000WF Product Family Intel Server Chassis R2000WF Product Family Intel Server System R1000WF Product Family Intel Server System R2000WF Product Family Building Blocks Server Systems Server Chassis Server Boards Intel Server S2600WF Product Family Intel Server System R2000WFTF ...

Page 14: ...Server System R1000WF product family A family of 1U rack mount server chassis integrated with an Intel Server Board S2600WF option o Intel Server System R2000WF product family A family of 2U rack mount server chassis integrated with an Intel Server Board S2600WF option o Intel Server System R2000WFTF product family A family of 2U rack mount server chassis integrated at level L9 with an Intel Serve...

Page 15: ...rmware In support of the 2nd Gen Intel Xeon processor Scalable family Intel began pre loading the supporting system software stack onto all server boards in the Intel Server S2600WF product family All server boards with pre loaded system software stacks compatible with the 2nd Gen Intel Xeon processor Scalable family can be identified by a product order code ending in R Existing server boards in t...

Page 16: ...41xx Silver 31xx Bronze of Intel UPI links 3 3 2 2 2 Intel UPI speed 10 4 GT s 10 4 GT s 10 4 GT s 9 6 GT s 9 6 GT s Supported topologies 2S 2UPI 2S 3UPI 4S 2UPI 4S 3UPI 8S 3UPI 2S 2UPI 2S 3UPI 4S 2UPI 4S 3UPI 2S 2UPI 4S 2UPI 2S 2UPI 2S 2UPI Node controller support Yes Yes No No No of memory channels 6 6 6 6 6 Max DDR4 speed 2666 MT s 2666 MT s 2400 MT s 2400 MT s 2133 MT s Memory capacity 768 GB ...

Page 17: ...1 of Intel UPI links 2 2 Intel UPI speed 10 4 GT s 10 4 GT s Supported topologies 2S 2UPI 2S 2UPI Node controller support No No of memory channels 6 6 Max DDR4 speed 2666 MT s 2666 MT s Memory capacity 768 GB 1 5 TB select SKUs 768 GB 1 5 TB select SKUs RAS capability Standard Standard Intel Turbo Boost Technology Yes Yes Intel Hyper Threading Technology Yes Yes Intel AVX 512 ISA support Yes Yes I...

Page 18: ... speed 2 DPC 2666 MT s 2666 MT s 2666 MT s 2400 MT s 2133 MT s Intel Optane DC persistent memory support Yes 1 Yes 1 Yes 1 4215 only 1 No Memory capacity 1 TB 2 TB select SKUs 4 5 TB select SKUs 1 TB 2 TB select SKUs 4 5 TB select SKUs 1 TB 2 TB select SKUs 4 5 TB select SKUs 1 TB 1 TB RAS capability Advanced Advanced Advanced Standard Standard Intel Turbo Boost Technology Yes Yes Yes Yes No Intel...

Page 19: ...r dependent See Table 1 and Table 2 o DDR4 ECC RDIMM up to 2666 MT s o DDR4 ECC LRDIMM up to 2666 MT s DDR4 standard voltage of 1 2 V 1 1 3 System Configuration Notes Single processor configurations require the processor to be installed in the processor 1 socket Processor 2 must be installed to use any of its 12 associated DIMM slots To ensure systems meet necessary airflow and thermal requirement...

Page 20: ...Update Safety and Regulatory Compliance Information for Intel Server System 4600 2600 2400 1600 Families For system integration and service instructions Intel Server System R1000WF Product Family System Integration and Service Guide Intel Server System R2000WF Product Family System Integration and Service Guide Intel Server System R2000WFTF Product Family System Integration and Service Guide For s...

Page 21: ...oard features Note Figure 3 provides an overview of available server board features Some features may not be present on all available server board options See Table 5 for a complete list of features supported on a given server board option Table 5 lists the features of the available server boards in the Intel Server Board S2600WF product family ...

Page 22: ...iPC X527DA4OCPG1P5 Dual Port 10Gb RJ45 iPC X557T2OCPG1P5 Dual Port SFP iPC X527DA2OCPG1P5 Quad Port 1Gb RJ45 iPC I357T4OCPG1P5 Quad Port SFP iPC X527DA4OCPG1P5 Dual Port 10Gb RJ45 iPC X557T2OCPG1P5 Dual Port SFP iPC X527DA2OCPG1P5 Intel Integrated SAS Module Supported Supported Supported Onboard PCIe NVMe 4 OCuLink connectors Intel VMD support Intel RSTe Intel VROC support accessory option 4 OCuLi...

Page 23: ... Management Integrated baseboard management controller IPMI 2 0 compliant Support for Intel Server Management software Dedicated onboard RJ45 management port Advanced server management via Intel RMM4 Lite iPC AXXRMM4LITE2 accessory option Security Trusted platform module 2 0 Rest of World iPC AXXTPMENC8 accessory option Trusted platform module 2 0 China Version iPC AXXTPMCHNE8 accessory option Sys...

Page 24: ...Intel Server S2600WF Product Family Configuration Guide 24 1 4 Intel Server Board S2600WFTF Product Family Figure 4 Intel Server Board S2600WFTF onboard features ...

Page 25: ...Port RJ45 10GbE OCP Module Support Dual Port 10Gb RJ45 iPC 557T2OCPG1P5 Dual Port SFP iPC 527DA2OCPG1P5 Intel Integrated SAS Module Supported Onboard PCIe NVMe Support 4 OCuLink connectors Intel VMD support Intel RSTe Intel VROC support accessory option Onboard SATA 12 SATA 6 Gbps ports 6 Gb s 3 Gb s and 1 5 Gb s transfer rates supported o 2 single port 7 pin SATA connectors o 2 M 2 connectors SAT...

Page 26: ...oard management controller IPMI 2 0 compliant Support for Intel Server Management software Dedicated onboard RJ45 management port Advanced server management via Intel RMM4 Lite iPC AXXRMM4LITE2 accessory option Security Trusted platform module 2 0 Rest of World iPC AXXTPMENC8 accessory option Trusted platform module 2 0 China Version iPC AXXTPMCHNE8 accessory option System Fan 6 system fans suppor...

Page 27: ...roduct Family This section gives an overview of the available systems in the Intel Server System R1000WF product family The xxx notation defines the specific product model or code For complete configuration details see Section 3 1 Figure 5 Intel Server System R1000WF feature set identification ...

Page 28: ...S2600WF Product Family Configuration Guide 28 Figure 6 1U 3 5 x 4 drive configuration Intel Server System R1304xxx Figure 7 1U 2 5 x 8 drive configuration Intel Server System R1208WFxxx Figure 8 1U system back panel ...

Page 29: ...4 Riser 2 PCIe 3 0 x24 With two riser cards installed up to two possible add in cards can be supported one x16 PCIe 3 0 add in card slot per riser card 2 full height half length add in cards via Risers 1 and 2 Power Supply Options The server system can have up to two power supply modules installed providing support for the following power configurations 1 0 1 1 redundant power and 2 0 combined pow...

Page 30: ...roduct Family This section gives an overview of the available systems in the Intel Server System R2000WF product family The xxx notation defines the specific product model or code For complete configuration details see Section 3 2 Figure 9 Intel Server System R2000WF feature set identification ...

Page 31: ... 31 Figure 10 2U No drive bays chassis only building block Intel Server Chassis R2000WFxxx Figure 11 2U 3 5 x 8 drive configuration Intel Server System R2308WFxxx Figure 12 2U 3 5 x 12 drive configuration Intel Server System R2312WFxxx storage configuration ...

Page 32: ...Figure 13 2U 2 5 x 8 drive configuration Intel Server System R2208WFxxx Figure 14 2U 2 5 x 16 drive configuration Intel Server System R2208WFxxx 8 drive accessory kit Figure 15 2U 2 5 x 24 drive configuration Intel Server System R2224WFxxx storage configuration ...

Page 33: ...ign Power TDP Up to 205 W Note Intel Server Systems in this family may support a lower maximum Thermal Design Power TDP See the appropriate Intel System TPS for maximum supported TDP External I O Connections DB 15 video connectors o Front and back non storage system configurations only RJ 45 serial port A connector Dual RJ 45 network interface connectors S2600WFT based systems only Dedicated RJ 45...

Page 34: ... SAS SATA o 8 x 2 5 combo backplane SAS SATA NVMe o 8 x 2 5 Dual Port SAS o 12 x 3 5 SAS SATA supports up to 2 NVMe drives Note All available backplane options have support for SAS 3 0 12 Gb sec Storage bay options o 8 x 3 5 SAS SATA hot swap drive bays o 12 x 3 5 SAS SATA hot swap drive bays supports up to 2 NVMe drives o 8 x 2 5 SAS SATA NVMe hot swap drive bays o 16 x 2 5 SAS SATA NVMe hot swap...

Page 35: ...duct Family This section gives an overview of the available systems in the Intel Server System R2000WFTF product family The xxx notation defines the specific product model or code For complete configuration details see Section 3 2 Figure 17 Intel Server System R2000WFTF feature set identification ...

Page 36: ... 2U 2 5 x 8 drive configuration Intel Server System LFRB2208WFTFxxx Figure 19 2U 3 5 x 12 drive configuration Intel Server System LFRB2312WFTFxxx storage configuration Figure 20 System back panel for Intel Server System R2000WFTF with optional 2 x 2 5 hot swap drive bay ...

Page 37: ... Connectors Headers 1 Type A USB 2 0 connector 1 DH 10 serial port B connector System Fans 6 managed 60 mm hot swap capable system fans Integrated fans included with each installed power supply module Riser Card Support Support for three riser cards Riser 1 PCIe 3 0 x24 up to 3 PCIe slots Riser 2 PCIe 3 0 x24 up to 3 PCIe slots Riser 3 PCIe 3 0 x16 up to 2 PCIe slots Low profile cards only optiona...

Page 38: ... PFR front panel o 16 8 8 accessory x 2 5 SAS SATA NVMe hot swap drive bays PFR front panel o 2 x 2 5 SATA SSD back of chassis hot swap drive bays accessory option o 2 x internal fixed mount 2 5 SSDs all system models Supported Rack Mount Kit Accessory Options AXXELVRAIL Enhanced value rack mount rail kit 424 mm max travel length 59 kg max supported weight AXXFULLRAIL 2U premium rail with CMA supp...

Page 39: ...for product code specific details The L9 systems listed are part of the Intel Data Center Blocks with Firmware Resilience product Table 10 Server board product family summary Intel Product Code iPC of CPU sockets of DIMM Slots of Riser Slots Onboard 10GbE LAN ports Onboard SATA ports 6 Gb Onboard NVMe Ports Intel SAS RAID Module support Intel Ethernet Network Adapter for OCP Support Onboard Video ...

Page 40: ...pt No No R2312WFQZS 2U S2600WFTQ 3 5 2 5 12 No Opt 8 Yes 1x 1300W AC Opt Opt Opt No No R2208WFTZS R 2U S2600WFT R 2 5 8 Up to 8 Opt 8 Yes 1x 1300W AC Opt Opt Opt No No R2208WF0ZS R 2U S2600WF0 R 2 5 8 Up to 8 Opt 8 Yes 1x 1300W AC Opt Opt Opt No No R2208WFQZS R 2U S2600WFQ R 2 5 8 Up to 8 Opt 8 Yes 1x 1300W AC Opt Opt Opt No No R2224WFTZS R 2U S2600WFT R 2 5 24 Up to 24 Opt 8 Yes 1x 1300W AC Opt O...

Page 41: ...hased separately and assembled by a system integrator At a minimum a base functional server system using building blocks requires the following 1U or 2U Intel Server Chassis Intel Server Board S2600WF product family option Power supply module s SATA NVMe data cables Power cord s Rack mount kit rails or fixed mount Processor Memory Storage devices Figure 21 Illustration of building block options In...

Page 42: ...Center Block with Firmware Resilience product Optional Intel accessories that can be added include the following Riser cards options Intel SAS SAS RAID support PCIe add in card or module and appropriate SAS data cable s Intel Ethernet Network Adapter for OCP to add additional features without losing a PCIe add in slot Intel Remote Management Module Lite key to add advanced server management featur...

Page 43: ...37151030 MOQ 1 Product type Server board only Building block spare FRU Packaged gross wt 3 3 kg 7 3 lb Un packaged net wt 1 7 kg 4 2 lb See Table 5 for the complete feature set Unique board features include Intel C624 chipset Onboard dual port RJ45 10 GbE LAN 4 onboard PCIe NVMe OCuLink connectors 12 SATA 6 Gbps ports Support for Intel Optane DC persistent memory module Box includes 1 server board...

Page 44: ...st Technology Intel QAT No onboard LAN 2 onboard PCIe NVMe OCuLinkconnectors 4 SATA 6 Gbps ports Box includes 1 server board and 1 Intel QAT cable Note All necessary mounting hardware cabling and shielding ship with the chassis and optional accessory kits OCuLink connectors from CPU1 can be used for NVMe drives OCuLink connectors from CPU2 are used for the Intel QAT link and do not work for NVMe d...

Page 45: ...are sold separately Optional accessories Some of the available accessories that can be installed to enhance the basic feature set of the server board chassis Optional accessories are sold separately Additional accessories can be found in Chapter 5 Note Items identified with an iPC Intel Product Code are orderable building block options accessories or spare FRUs In an effort to provide the complete...

Page 46: ... heat sinks 39 fin passive iPN J39509 xxx 2 CPU heat sink No CPU label inserts iPN J16115 xxx 2 Standard CPU carriers iPN H72851 xxx 2 1 slot PCIe x16 Riser Card iPN H88399 xxx 8 DIMM slot blanks iPN G75158 xxx 1 Chassis Stiffener Bar iPN J16623 xxx 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H23961 00x Server board and riser card mounting screws Spares for each sc...

Page 47: ...C FR1UFAN10PW 2 CPU heat sinks 39 fin passive iPN J39509 xxx 2 CPU heat sink No CPU label inserts iPN J16115 xxx 2 Standard CPU carriers iPN H72851 xxx 2 1 slot PCIe x16 Riser Card iPN H88399 xxx 8 DIMM slot blanks iPN G75158 xxx 1 Chassis Stiffener Bar iPN J16623 xxx 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H23961 00x Server board and riser card mounting screws...

Page 48: ...l Server Board S2600WF choose one o iPC S2600WFT R o iPC S2600WF0 R o iPC S2600WFQ R Power supply module s choose one type 2 common modules required for redundancy o 1300W AC power supply module iPC AXX1300TCRPS o 1100W AC power supply module iPC AXX1100PCRPS o 750 W DC power supply module iPC AXX750DCCRPS Power cord s See Section 5 6 Rack mount kit See Section 5 7 1 or 2 1st or 2nd Gen Intel Xeon...

Page 49: ...ble iPN H91172 xxx 1 Internal fixed mount 250 mm SSD drive power cable iPN J29245 xxx 2 Riser Card mounting brackets supporting up to 3 riser cards riser cards sold separately see Section 5 2 1 Power supply bay blank insert Server Board and Riser Card mounting screws Spares for each screw type included Intel Server Board S2600WF choose one o iPC S2600WFT R o iPC S2600WF0 R o iPC S2600WFQ R Power s...

Page 50: ...ire only the addition of power cords and storage devices to become a functional server L9 systems are a part of the Intel Data Center Block with Firmware Resilience product Optional Intel accessories that can be added include Second power supply module to add power redundancy Intel RAID support PCIe add in card or module and appropriate SAS data cable s Intel RAID Maintenance Free Backup unit Inte...

Page 51: ...hance the basic feature set of the server board chassis Optional accessories are sold separately Additional accessories can be found in Chapter 5 Note Items identified with an iPC Intel Product Code are orderable building block options accessories or spare FRUs In an effort to provide the complete product bill of materials the ship along components list in each product table include items identifi...

Page 52: ...71 xxx 1 850 mm mini SAS HD cable iPC AXXCBL850HDHRT 1 350 mm backplane power cable iPN H82100 xxx 1 Air duct iPN H90054 xxx 6 Dual rotor system fans iPC FR1UFAN10PW 1 1100W power supply module iPC AXX1100PCRPS 2 CPU heat sinks 39 fin passive iPN J39509 xxx 2 CPU heat sink No CPU label inserts iPN J16115 xxx 2 Standard CPU Carriers iPN H72851 xxx 8 DIMM slot blanks iPN G75158 xxx 1 Chassis Stiffen...

Page 53: ...e iPN H91171 xxx 1 850 mm mini SAS HD cable iPC AXXCBL850HDHRT 1 350 mm backplane power cable iPN H82100 xxx 1 Air duct iPN H90054 xxx 6 Dual rotor system fans iPC FR1UFAN10PW 1 1100W power supply module iPC AXX1100PCRPS 2 CPU heat sinks 39 fin passive iPN J39509 xxx 2 CPU heat sink No CPU label inserts iPN J16115 xxx 2 Standard CPU Carriers iPN H72851 xxx 8 DIMM slot blanks iPN G75158 xxx 1 Chass...

Page 54: ... 350 mm backplane power cable iPN H82100 xxx 1 SATA optical drive power cable 300 mm iPN H23901 001 1 SATA optical drive bay mounting kit iPN H19168 xxx 1 Air duct iPN H90054 xxx 6 Dual rotor system fans iPC FR1UFAN10PW 1 1100W power supply module iPC AXX1100PCRPS 2 CPU heat sinks 39 fin passive iPN J39509 xxx 2 CPU heat sink No CPU label inserts iPN J16115 xxx 2 Standard CPU Carriers iPN H72851 x...

Page 55: ...L850HDHRT 1 350 mm backplane power cable iPN H82100 xxx 1 SATA optical drive power cable 300 mm iPN H23901 001 1 SATA optical drive bay mounting kit iPN H19168 xxx 1 Air duct iPN H90054 xxx 6 Dual rotor system fans iPC FR1UFAN10PW 1 1100W power supply module iPC AXX1100PCRPS 2 CPU heat sinks 39 fin passive iPN J39509 xxx 2 CPU heat sink No CPU label inserts iPN J16115 xxx 2 Standard CPU Carriers i...

Page 56: ...PN H82099 xxx 1 SATA optical drive power cable 300 mm iPN H23901 001 1 SATA optical drive bay mounting kit iPN H19168 xxx 1 Air duct iPN H90054 xxx 6 Dual rotor system fans iPC FR1UFAN10PW 1 1100W power supply module iPC AXX1100PCRPS 2 CPU heat sinks 39 fin passive iPN J39509 xxx 2 CPU heat sink No CPU label inserts iPN J16115 xxx 2 Standard CPU carriers iPN H72851 xxx 8 DIMM slot blanks iPN G7515...

Page 57: ...wer cable iPN H82099 xxx 1 SATA optical drive power cable 300 mm iPN H23901 001 1 SATA optical drive bay mounting kit iPN H19168 xxx 1 Air duct iPN H90054 xxx 6 Dual rotor system fans iPC FR1UFAN10PW 1 1100W power supply module iPC AXX1100PCRPS 2 CPU heat sinks 39 fin passive iPN J39509 xxx 2 CPU heat sink No CPU label inserts iPN J16115 xxx 2 Standard CPU carriers iPN H72851 xxx 8 DIMM slot blank...

Page 58: ...ir duct iPN H90054 xxx 6 Dual rotor system fans iPC FR1UFAN10PW 1 1100 W power supply module iPC AXX1100PCRPS 2 CPU heat sinks 39 fin passive iPN J39509 xxx 2 CPU heat sink No CPU label inserts iPN J16115 xxx 2 Standard CPU carriers iPN H72851 xxx 8 DIMM slot blanks iPN G75158 xxx 1 Chassis Stiffener Bar iPN J16623 xxx 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H2...

Page 59: ...f the server board chassis Additional accessories can be found in Chapter 4 NOTES Each required item and optional accessory are sold separately for the specified Intel L6 server system Items identified as iPC Intel Product Code are an orderable building block option accessory or spare FRU In an effort to provide the complete product bill of materials the ship along components list in each product ...

Page 60: ...xx 1 SATA optical drive power cable 300 mm iPN H23901 001 1 SATA optical drive bay mounting kit iPN H19168 xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 8 DIMM slot blanks iPN G75158 00x 1 1300W AC power supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU ...

Page 61: ...PN H82099 xxx 1 SATA optical drive power cable 300 mm iPN H23901 001 1 SATA optical drive bay mounting kit iPN H19168 xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 8 DIMM slot blanks iPN G75158 00x 1 1300W AC power supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X1...

Page 62: ...it iPN H19168 xxx 1 Standard 2U Air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 8 DIMM slot blanks iPN G75158 00x 1 1300W AC power supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Standard CPU carrier iPN H72851 xxx 1 3...

Page 63: ...mounting kit iPN H19168 xxx 1 Standard 2U Air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 8 DIMM slot blanks iPN G75158 00x 1 1300W AC power supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Standard CPU carrier iPN H728...

Page 64: ...ng kit iPN H19168 xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 8 DIMM slot blanks iPN G75158 00x 1 1300W AC power supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC Power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Standard CPU carrier iPN H72851 xxx...

Page 65: ... bay mounting kit iPN H19168 xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 8 DIMM slot blanks iPN G75158 00x 1 1300W AC power supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC Power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Standard CPU carrier iPN...

Page 66: ...y module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Standard CPU carrier iPN H72851 xxx 1 3x Intel RAID Maintenance Free Backup unit mounting bracket iPN H18238 00x 1 250 mm fixed mount SSD power cable iPN J29245 xxx Spares for each screw type...

Page 67: ...wer supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Standard CPU carrier iPN H72851 xxx 1 3x Intel RAID Maintenance Free Backup unit mounting bracket iPN H18238 00x 1 250 mm fixed mount SSD power cable iPN J29245 xxx Spares for each s...

Page 68: ... VGA and 2 x USB o 620 mm USB 3 0 cable iPN H76899 xxx o 400 mm video cable iPN H62114 xxx 1 RFID antenna iPN H69566 xxx 1 250 mm backplane I2C cable iPN H91166 xxx 2 730 mm mini SAS HD cable iPC AXXCBL730HDHD 1 400 525 675 mm backplane power cable iPN H82108 XXX 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 8 DIMM slot blanks iPN G75158 00x 2 1300W AC power supply ...

Page 69: ... and 2 x USB o 620 mm USB 3 0 cable iPN H76899 xxx o 400 mm video cable iPN H62114 xxx 1 RFID antenna iPN H69566 xxx 1 250 mm backplane I2C cable iPN H91166 xxx 2 730 mm mini SAS HD cable iPC AXXCBL730HDHD 1 400 525 675 mm backplane power cable iPN H82108 XXX 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 8 DIMM slot blanks iPN G75158 00x 2 1300W AC power supply modu...

Page 70: ...GA and 2 x USB o 620 mm USB 3 0 cable iPN H76899 xxx o 400 mm video cable iPN H62114 xxx 1 RFID antenna iPN H69566 xxx 1 250 mm backplane I2C cable iPN H91166 xxx 2 730 mm mini SAS HD cable iPC AXXCBL730HDHD 1 400 525 675 mm backplane power cable iPN H82108 XXX 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 8 DIMM slot blanks iPN G75158 00x 2 1300W AC power supply mo...

Page 71: ...ndard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 16 DIMM slot blanks iPN G75158 00x 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Standard CPU carrier iPN H72851 xxx 2 Chassis handle 1 set installed iPN H18229 xxx 1 3x Intel RAID Maintenan...

Page 72: ... xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 16 DIMM slot blanks iPN G75158 00x 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Standard CPU carrier iPN H72851 xxx 2 Chassis handle 1 set installed iPN H18229 xxx 1 3x Intel RAID...

Page 73: ...5 mm backplane power cable iPN H82097 xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 16 DIMM slot blanks iPN G75158 00x 1 1300W AC power supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Standard CPU c...

Page 74: ...HD 1 525 675 mm backplane power cable iPN H82097 xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 16 DIMM slot blanks iPN G75158 00x 1 1300W AC power supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Sta...

Page 75: ... 250 mm fixed mount SSD power cable iPN J29245 xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 16 DIMM slot blanks iPN G75158 00x 1 1300W AC power supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC Power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Stand...

Page 76: ...0 mm front panel cable iPN H26893 xxx 1 640 mm front panel USB 2 0 cable iPN H20005 xxx 1 RFID antenna iPN H69566 xxx 1 175 mm backplane I2C cable iPN H91172 xxx 1 800 mm mini SAS HD cable iPC AXXCBL800HDHD 1 875 mm mini SAS HD cable iPC AXXCBL875HDHD 1 950 mm mini SAS HD cable iPC AXXCBL950HDHD 1 525 675 mm backplane power cable iPN H82097 xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap syst...

Page 77: ... front panel cable iPN H26893 xxx 1 640 mm front panel USB 2 0 cable iPN H20005 xxx 1 RFID antenna iPN H69566 xxx 1 175 mm backplane I2C cable iPN H91172 xxx 1 800 mm mini SAS HD cable iPC AXXCBL800HDHD 1 875 mm mini SAS HD cable iPC AXXCBL875HDHD 1 950 mm mini SAS HD cable iPC AXXCBL950HDHD 1 525 675 mm backplane power cable iPN H82097 xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system f...

Page 78: ...mm front panel cable iPN H26893 xxx 1 640 mm front panel USB 2 0 cable iPN H20005 xxx 1 RFID antenna iPN H69566 xxx 1 175 mm backplane I2C cable iPN H91172 xxx 1 800 mm mini SAS HD cable iPC AXXCBL800HDHD 1 875 mm mini SAS HD cable iPC AXXCBL875HDHD 1 950 mm mini SAS HD cable iPC AXXCBL950HDHD 1 525 675 mm backplane power cable iPN H82097 xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system...

Page 79: ...lanks iPN G75158 00x 1 1300W AC power supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC Power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Standard CPU carrier iPN H72851 xxx 1 3x Intel RAID Maintenance Free Backup unit mounting bracket iPN H18238 00x 1 250 mm fixed mount SSD power cabl...

Page 80: ...PN H82108 xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 16 DIMM slot blanks iPN G75158 00x 1 1300W AC power supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC Power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Standard CPU carrier iPN H72851 xxx 1 3x I...

Page 81: ...er cable iPN H82108 xxx 1 Standard 2U air duct iPN H90554 xxx 6 Hot swap system fans iPC FR2UFAN60HSW 16 DIMM slot blanks iPN G75158 00x 1 1300W AC power supply module iPC AXX1300TCRPS 1 Power supply bay blank insert 2 AC Power cord retention strap assembly iPN H23961 00x 2 CPU heat sinks iPC FXXCA78X108HS 2 CPU heat sink NO CPU Mylar spacer insert iPN J16115 XXX 2 Standard CPU carrier iPN H72851 ...

Page 82: ...A SAS drives Backplanes that include support for 2 5 PCIe NVMe drives also include one PCIe OCuLink connector for each PCIe NVMe drive it supports Drive numbers in the cable configuration tables match the specific cable connectors found on the given backplane Figure 21 SAS backplane Note The back side cable connector side of a backplane will have one OCuLink cable connector for each PCIe NVMe SFF ...

Page 83: ...ors SATA 0 3 SATA 4 7 All 12 Gb sec SAS capable hot swap backplanes All 12 Gb sec SAS RAID Controllers All 12 Gb sec SAS Expander Cards Table 49 PCIe OCuLink cable connectors Image Description OCuLink connector Support for PCIe NVMe SFF 2 5 SSDs Where used On the server board 2 or 4 connectors depending on the board model All backplanes that include support for NVMe SFF SSDs Table 50 Intel Omni Pa...

Page 84: ... following table identifies the different data cable connector types and the identifiers used in the cable kit product codes Table 51 Data cable connector identification Connector Image Cable Code Description HR Right angle SFF 8643 mini SAS HD connector HD Straight SFF 8643 mini SAS HD connector CV Straight NVMe OCuLink SFF 8611 connector CR Right angle NVMe OCuLink SFF 8611 connector R1 L1 IFT C...

Page 85: ...Note The minimum order quantity MOQ refers to the cable kit The kit contents may include one or more cables as listed in the product description Table 52 SATA SAS NVMe data cable kit description and order information Image Details Description iPC AXXCBL950HDHD MM 936122 UPC 00735858286596 EAN 5032037066495 MOQ 1 950 mm long cable kit 2 cables included straight SFF8643 to straight SFF8643 Used in m...

Page 86: ...are cable kit 235 mm long iPN H79267 xxx 1 cable included This is a replacement cable for IFT Carrier kit AWF1PFABKITP Updated 10 19 iPC AXXCBL370IFPS1 MM 958251 UPC 00735858346085 EAN 5032037106368 MOQ 1 Accessory cable kit 370 mm long iPN H79275 xxx 1 cable included This is an accessory cable for IFT Carrier Kit AWF1PFABKITM A required cable to connect fabric processor 2 to the Mezzanine IFT Car...

Page 87: ... R2224 systems to connect a server board OCuLink SSD connector to a HSBP SSD connector CV CR iPC AXXCBL530CVCR MM 958260 UPC 00735858346153 EAN 5032037106436 MOQ 1 530 mm long accessory cable kit 1 cable included straight OCuLink SFF 8611 connector to right angle OCuLink SFF 8611 connector Used in R1208 R2208 R2208 8 and R2224 systems to connect the server board OCuLink SSD connector to a HSBP SSD...

Page 88: ...bundled cable 890 mm long bundled cable kit 1 cable included right angle OCuLink SFF 8611 connectors to straight right angle OCuLink SFF 8611 connectors Used in the R1208 to connect switch AIC to HSBP PCIe SSD ports iPC A2U4PSWCXCXK1 MM 958266 UPC 00735858346221 EAN 5032037106504 MOQ 1 2U 4 port Switch accessory cable kit Riser 1 or Riser 2 1 cable included Contains the following OCuLink bundled c...

Page 89: ...mm long bundled cable kit 2 cables included straight OCuLink SFF 8611connectors to straight right angle OCuLink SFF 8611 connectors Used in the R2224 to connect switch AIC 2 installed in Riser 2 to HSBP PCIe SSD ports 0 7 iPC AXXCBL700HDCV MM 958273 UPC 00735858346276 EAN 5032037106559 MOQ 1 700 mm long cable kit 2 cables included straight SFF 8643 connector to dual straight OCuLink SFF 8611 conne...

Page 90: ...ides enough cable to attach the two devices and provides the least amount of excess cable providing the cleanest cable routing Refer to the following diagrams when Right or Left cable routing is specified for a given cable configuration All cable recommendations are for a system configured for two processors Figure 22 Server system cable routing LEFT LEFT RIGHT RIGHT Front drive bays Front drive b...

Page 91: ...1 cable The following cable is required for Mezzanine SAS ROC modules with Horizontal connectors SAS Mezz BP 0 3 800 mm HD HD AXXCBL800HDHD The following cable is required for Mezzanine SAS ROC modules with Vertical connectors AXXCBL850HDHRS From Riser 1 SAS PCIe BP 0 3 1 875 or 950 mm HD HD From Riser 2 SAS PCIe BP 0 3 1 730 or 875 mm HD HD From data above select appropriate cable kits from list ...

Page 92: ...L650HDHD SAS Mezz BP 4 7 800 mm HD HD AXXCBL800HDHD Mezzanine SAS ROC Modules with vertical connectors require the following cable kit AXXCBL850HDHRS for backplane drives 0 3 From Riser 1 SAS PCIe BP 0 3 650 mm HD HD SAS PCIe BP 4 7 1 730 or 800 mm HD HD From Riser 2 SAS PCIe BP 0 3 1 650 or 730mm HD HD SAS PCIe BP 4 7 800 or 875 mm HD HD From data above select appropriate cable kits from list bel...

Page 93: ...HD HD AXXCBL875HDHD L6 systems ship with 1 each cable SAS Mezz BP 0 3 730 mm HD HD AXXCBL730HDHD SAS Mezz BP 4 7 875 mm HD HD AXXCBL875HDHD From Riser 1 SAS PCIe BP 0 3 1 650 or 730 mm HD HD SAS PCIe BP 4 7 1 800 or 950 mm HD HD From Riser 2 SAS PCIe BP 0 3 1 730 or 800 mm HD HD SAS PCIe BP 4 7 1 730 or 800 mm HD HD From data above select appropriate cable kits from list below See Notes below AXXC...

Page 94: ...AS Mezz BP 8 11 950 mm HD HD From data above select appropriate cable kits from list below AXXCBL800HDHD AXXCBL875HDHD AXXCBL950HDHD L6 systems ship with 1 each of the cables listed From Riser 1 SAS PCIe BP 4 7 1 800 or 875 mm HD HD SAS PCIe BP 8 11 875 mm HD HD From Riser 2 SAS PCIe BP 4 7 1 730 or 875 mm HD HD SAS PCIe BP 8 11 1 650 or 800 mm HD HD From data above select appropriate cable kits s...

Page 95: ...0735858287548 EAN 5032037067287 MOQ 5 Product type 2U accessory kit 6Gbps data aggregation for 12Gbps data transfer with 6Gb s devices Low Profile MD2 PCIe add in card form factor 28 internal ports and 8 external ports Redundant dual port capable for HA and high performance systems Power from PCIe x1 Mini SAS HD 8643 Connectors Kit includes 1 SAS expander card 2 HD HD 250mm Expander to RAID card c...

Page 96: ...XXCBL875HDHD With 12 Gb SAS Expander RES3FV288 installed in Riser 1 Use cables in Expander Kit to attach SAS ROC to Expander Card Use the following cables to attach Expander to Backplane Expander BP 0 3 800 mm HD HD Expander BP 4 7 875 mm HD HD Expander BP 8 11 950 mm HD HD From data above select appropriate cable kits from list below AXXCBL800HDHD AXXCBL875HDHD AXXCBL950HDHD L6 systems ship with ...

Page 97: ...will include two 4 port 8643 Mini SAS HD data connectors Ports 0 3 Ports 4 7 for SAS SATA support and eight PCIe OCuLink connectors for NVMe support one connector for each PCIe NVMe SFF drive Each OCuLink connector is labeled with a Drive ID 0 7 which corresponds to a matching drive interface connector on the front side drive interface side of the backplane Note The dual port SAS backplane option ...

Page 98: ...D mezzanine and PCIe add in options to the 8x2 5 backplane installed to Drive Bay Module 1 Table 59 Drive bay module 1 SAS SATA cable guide System Configuration SAS SATA Drive Support SATA Onboard Multi port SATA Ports to Backplane BP 1 SAS Mezzanine 12 Gb SAS ROC Module to Backplane BP 1 SAS 12 Gb SAS RAID PCIe add in card to Backplane BP 1 Drive Bay 1 R2208WF R2208WF 8 R2224WF Up to eight 2 5 SA...

Page 99: ...SD 0 CR BP 0 CV 470mm AXXCBL470CVCR PCIe SSD 1 CR BP 1 CV 530mm AXXCBL530CVCR PCIe SSD 2 CR BP 2 CV 700mm AXXCBL700CVCR PCIe SSD 3 CR BP 3 CV 700mm AXXCBL700CVCR PCIe SSD 0 CR BP 4 CV 700mm AXXCBL700CVCR PCIe SSD 1 CR BP 5 CV 700mm AXXCBL700CVCR PCIe SSD 2 CR BP 6 CV 700mm AXXCBL700CVCR PCIe SSD 3 CR BP 7 CV 700mm AXXCBL700CVCR All cables routed left 4 port PCIe Switch Add in Card AXXP3SWX08040 an...

Page 100: ...ght 2 5 NVMe SSDs PCIe SSD 0 CR BP 0 CV 470mm AXXCBL470CVCR PCIe SSD 1 CR BP 1 CV 530mm AXXCBL530CVCR PCIe SSD 2 CR BP 2 CV 600mm AXXCBL600CVCR PCIe SSD 3 CR BP 3 CV 600mm AXXCBL600CVCR PCIe SSD 0 CR BP 4 CV 600mm AXXCBL600CVCR PCIe SSD 1 CR BP 5 CV 600mm AXXCBL600CVCR PCIe SSD 2 CR BP 6 CV 600mm AXXCBL600CVCR PCIe SSD 3 CR BP 7 CV 600mm AXXCBL600CVCR All cables routed left 4 port PCIe Retimer Add...

Page 101: ...D From data above select appropriate cable kits from list below AXXCBL730HDHD 1 730mm Included in all 2 5 L6 AXXCBL875HDHD 1 875mm Included in R2224 L6 SAS Mezz BP 0 3 730mm HD HD SAS Mezz BP 4 7 875mm HD HD From data above select appropriate cable kits from list below AXXCBL730HDHD 1 730mm Included in all 2 5 L6 AXXCBL875HDHD 1 875mm Included in R2224 L6 From Riser 1 SAS PCIe BP 0 3 1 650 or 730m...

Page 102: ... Eight 2 5 NVMe SSDs PCIe SSD 0 CR BP 0 CV 700mm AXXCBL700CVCR Route Left PCIe SSD 1 CR BP 1 CV 700mm AXXCBL700CVCR Route Left PCIe SSD 2 CR BP 2 CV 700mm AXXCBL700CVCR Route Right PCIe SSD 3 CR BP 3 CV 700mm AXXCBL700CVCR Route Right PCIe SSD 0 CR BP 4 CV 700mm AXXCBL700CVCR Route Left PCIe SSD 1 CR BP 5 CV 700mm AXXCBL700CVCR Route Left PCIe SSD 2 CR BP 6 CV 700mm AXXCBL700CVCR Route Right PCIe ...

Page 103: ...ATA 4 7 BP 4 7 730mm HD HD From data above select appropriate cable kits from list below AXXCBL730HDHD 2 730mm cables Included in all 2 5 L6 AXXCBL800HDHD SAS Mezz BP 0 3 730mm HD HD SAS Mezz BP 4 7 730mm HD HD From data above select appropriate cable kits from list below AXXCBL730HDHD 2 730mm cables Included in all 2 5 L6 From Riser 1 SAS PCIe BP 0 3 1 730 or 875mm HD HD SAS PCIe BP 4 7 1 800 or ...

Page 104: ...CV 800mm AXXCBL800CVCR PCIe SSD 1 CR BP 1 CV 800mm AXXCBL800CVCR PCIe SSD 2 CR BP 2 CV 600mm AXXCBL600CVCR PCIe SSD 3 CR BP 3 CV 600mm AXXCBL600CVCR PCIe SSD 0 CR BP 4 CV 800mm AXXCBL800CVCR PCIe SSD 1 CR BP 5 CV 800mm AXXCBL800CVCR PCIe SSD 2 CR BP 6 CV 530mm AXXCBL530CVCR PCIe SSD 3 CR BP 7 CV 530mm AXXCBL530CVCR All cables routed Right 4 port PCIe Switch Add in Card AXXP3SWX08040 any open PCIe ...

Page 105: ...Me SSDs PCIe SSD 0 CR BP 0 CV 800mm AXXCBL800CVCR PCIe SSD 1 CR BP 1 CV 800mm AXXCBL800CVCR PCIe SSD 2 CR BP 2 CV 600mm AXXCBL600CVCR PCIe SSD 3 CR BP 3 CV 600mm AXXCBL600CVCR PCIe SSD 0 CR BP 4 CV 800mm AXXCBL800CVCR PCIe SSD 1 CR BP 5 CV 800mm AXXCBL800CVCR PCIe SSD 2 CR BP 6 CV 530mm AXXCBL530CVCR PCIe SSD 3 CR BP 7 CV 530mm AXXCBL530CVCR All cables routed Right 4 port PCIe Retimer Add in Card ...

Page 106: ... SAS expander option to support these drive configurations Table 65 SAS expander option Image Details Description SAS 3 0 12 Gb s Expander iPC RES3TV360 MM 932894 UPC 00735858287364 EAN 5032037067102 MOQ 5 Product type 2U accessory kit 6Gbps data aggregation for 12Gbps data transferwith 6Gb s devices Internal mount mid plane form factor 36 internal ports supporting point to point 12 6 and 3 Gb s d...

Page 107: ...m list below AXXCBL730HDHD 2 730mm cables Included in all 2 5 L6 systems 12 Gb SAS Expander RES3TV360 installed From Riser 1 SAS PCIe Exp 0 3 G 650mm HD HD SAS PCIe Exp 4 7 H 650mm HD HD From Riser 2 SAS PCIe Exp 0 3 G 730mm HD HD SAS PCIe Exp 4 7 H 730mm HD HD From data above select appropriate cable kits from list below AXXCBL650HDHD AXXCBL730HDHD 2 730mm cables Included in all 2 5 L6 systems 12...

Page 108: ...Swap Drive Bay Accessory Kit iPC A2UREARHSDK2 MM 958243 UPC 00735858344876 EAN 5032037105583 MOQ 1 Product type 2U accessory kit Building block Kit Includes 1 Drive Bay Assembly and mounting hardware 2 2 5 Hot Swap Drive Carriers 2 SATA Data Cables 1 Power Cable 1 I2C Cable 1 SGPIO cable 2U Fixed Mount SSD and Rear Drive Bay Cable Kit iPC A2UCBLSSD MM 937328 UPC 735858287005 EAN 5032037066747 MOQ ...

Page 109: ...hnical Product Specifications TPS for additional information Riser slots 1 and 2 are capable of supporting up to 75W maximum power each Available power to each add in card slot on a given riser card is defined by the PCIe specification The server board provides two auxiliary 12V power connectors that when cabled iPC AXXGPGPUCABLE can provide additional power to high power PCIe add in cards 5 2 1 1...

Page 110: ... FRU 2U accessory kit Riser card option for riser slots 1 and 2 Required for Intel Xeon Phi coprocessor or high power PCIe add in card support Each two slot riser card assembly has support for one full height full length add in card top slot and one full height half length add in card bottom slot Slot 1 top PCIe x16 elec x16 mechanical Slot 2 bottom PCIe x8 elec x8 mechanical Kit includes 1 Riser ...

Page 111: ... how they are cabled to the backplane Each drive bay will include a single backplane Each backplane will include a multi port data connector for each set of four drives Ex for an 8 drive configuration the backplane will include 2 four port data connectors In the illustration above drives showing a common Drive ID label color share a common data connector on the backside of the given backplane R220...

Page 112: ...t swap backplane 8 2 5 drive carriers and drive blanks 1 75 mm I2C backplane to backplane jumper cable 1 set mounting hardware Required sold separately SAS SATA data cables See Chapter 4 2U Hot Swap 8 x 2 5 SAS NVMe Combo Drive Bay Kit iPC A2U8X25S3PHS MM 955858 UPC 00735858344852 EAN 5032037105569 MOQ 1 Product type 2U drive upgrade kit 2U building block 8x2 5 SAS NVMe Combo Front Mount Hot Swap ...

Page 113: ... OCP The Intel S2600WF product family includes support for a number of optional OCP modules that install onto proprietary connectors on the server board leaving all available PCIe add in cards slots available for other add in card options Figure 34 Intel Ethernet Network Adapter for OCP installation ...

Page 114: ...rt SFP OCP Module OCP PHY Mezzanine Type1 Type 2 AIC 2 x SFP uplinks 2 x KR host connections via OCP PHY Mezzanine Connector C Intel Ethernet Network Connection OCP X527 DA4 iPC X527DA4OCPG1P5 MM 950127 UPC 00735858328852 EAN 5032037095051 MOQ 1 Product type 1U 2U accessory kit Quad port SFP OCP Module OCP PHY Mezzanine Type1 Type 2 AIC 4 x SFP uplinks 4 x KR host connections via OCP PHY Mezzanine...

Page 115: ...032037060448 MOQ 5 Product type 1U 2U accessory kit SAS 3 0 12 Gb s Mezzanine Form Factor HW RAID Module 8 internal SAS SATA ports Mini SAS HD SFF8643 connectors LSI SAS3108 ROC with 1GB DDR3 RAID Levels 0 1 5 6 10 50 60 Embedded 1GB DDR3 Cache Memory Supports Maintenance Free Backup Unit iPC AXXRMFBU5 Supports the following Intel RAID Accessory Options Intel RAID SSD Cache with Fast Path I O iPC ...

Page 116: ... Module 8 internal SAS SATA ports Mini SAS HD SFF8643 connectors LSI SAS3008 IOC with Basic Firmware Entry hardware RAID levels JBOD RAID 0 1 1E 10 SAS data cables not included and must be purchased separately Intel Integrated RAID Module RMS3VC160 iPC RMS3VC160 MM 946902 UPC 00735858308595 EAN 5032037081351 MOQ 5 Product type 1U 2U accessory kit Mezzanine Form Factor RAID Module Entry Level SAS R...

Page 117: ...Module RMSP3AD160F iPC RMSP3AD160F MM 954552 UPC 00735858329149 EAN 5032037095266 MOQ 5 Product type 1U 2U accessory kit Mezzanine Form Factor RAID Module Full Featured Tri Mode RAID Controller 16 internal SAS SATA ports 4 NVMe Avago SAS3516 ROC RAID Levels 0 1 10 5 6 50 60 and JBOD Supports Maintenance Free Backup Unit iPC AXXRMFBU7 Supports the following Intel RAID Accessory Options Intel RAID D...

Page 118: ...rofile half length MD2 Compliant PCIe add in card 4 internal SAS SATA ports LSI SAS3108 ROC RAID Levels 0 1 5 6 10 50 and 60 Embedded 1GB DDR3 Cache Memory Supports Maintenance Free Backup Unit iPC AXXRMFBU4 Supports the following Intel RAID Accessory Options Intel RAID SSD Cache with Fast Path I O iPC AXXRPFKSSD2 Intel RAID Drive Encryption Management iPC AXXRPFKDE2 Intel RAID Rapid Recovery Snap...

Page 119: ...nternal SAS SATA ports LSI SAS3008 IOC RAID Levels 0 1 1E 10 and JBOD SAS data cables not included and must be purchased separately Intel RAID Controller RS3WC080 iPC RS3WC080 MM 928215 UPC 00735858267656 EAN 5032037053945 MOQ 5 Product type 1U 2U accessory kit Low Profile half length MD2 Compliant PCIe add in card Entry Level SAS RAID Controller 8 internal SAS SATA ports LSI SAS3008 IOC RAID Leve...

Page 120: ... LSI SAS3416 IOC RAID Levels JBOD SAS SATA NVMe Connectivity SAS and NVMe data cables not included and must be purchased separately Intel RAID Controller RSP3WD080E iPC RSP3WD080E MM 954557 UPC 00735858329170 EAN 5032037095297 MOQ 5 Product type 1U 2U accessory kit Low Profile half length MD2 Compliant PCIe add in card Entry level Tri Mode RAID Controller 8 internal SAS SATA ports 2 NVMe Avago SAS...

Page 121: ...ssory Options Intel RAID Drive Encryption Management iPC AXXRPFKDE2 SAS and NVMe data cables not included and must be purchased separately Intel RAID Controller RSP3MD088F iPC RSP3MD088F MM 954551 UPC 00735858329194 EAN 5032037095310 MOQ 5 Product type 1U 2U accessory kit Low Profile half length MD2 Compliant PCIe add in card Full Featured Tri Mode RAID Controller 8 internal 8 external SAS SATA po...

Page 122: ...duct type 1U 2U accessory kit Upgrade key to enable drive encryption management for Intel RAID Controller RS25 and RS3 based on LSI 3108 families of ROC products Intel RAID Rapid Recovery Snapshot iPC AXXRPFKSNSH2 MM 915318 UPC 00735858221481 EAN 5032037051712 MOQ 5 Product type 1U 2U accessory kit Upgrade key to enable rapid recovery snapshot for Intel RAID Controller RS25 and RS3 based on LSI 31...

Page 123: ...337274 EAN 5032037100021 MOQ 5 Product type 1U 2U accessory kit Activation key to support RAID 0 1 5 10 functionality only on NVMe SSDs from Intel Intel Virtual RAID on CPU Intel VROC Standard Model Key iPC VROCSTANMOD MM 951605 UPC 00735858337243 EAN 5032037100007 MOQ 5 Product type 1U 2U accessory kit Activation key to support non Intel NVMe SSDs and enable RAID 0 1 10 functionality Intel Virtua...

Page 124: ...ent The AXXRMFBU6 is used with the full featured RAID controllers Compatible with Intel Integrated RAID Module RMS3AC160 Intel RAID Maintenance Free Backup Unit AXXRFMBU5 iPC AXXRMFBU5 MM 933907 UPC 00735858276801 EAN 5032037060417 MOQ 5 Product type 1U 2U accessory kit A super capacitor module and flash memory card designed to help protect data in dynamic memory during a power failure or system c...

Page 125: ...e 1U 2U accessory kit Kit includes 1 2U RMFBU mounting plate The mounting plate installs in one of two possible mounting locations on the 2U air duct and can support up to two AXXRMFBU5 or AXXRSBBU9 units Full length PCIe cards cannot be supported when this mounting plate is installed behind the given riser slot 1 RMFBU plastic housing bracket to support two stacked AXXRMFBU5 units in a 1U chassis...

Page 126: ... 1 Product type 1U 2U building block spare FRU 1U 2U accessory kit 1300 W AC common redundant power supply with 80 PLUS Titanium efficiency Power cord sold separately 750W AC Common Redundant Power Supply iPC AXX750DCCRPS MM 927253 UPC 00735858260862 EAN 5032037051354 MOQ 1 Product type 1U 2U building block spare FRU 1U 2U accessory kit 750 W DC common redundant power supply with 80 PLUS Gold effi...

Page 127: ...guration Guide 127 Image Details Description 1500 mm 59 in North America power cable iPC FPWRCABLENA MM 879287 UPC 00735858181129 EAN 5032037015738 MOQ 1 Product type 1U 2U spare FRU 1U 2U accessory kit 1500 mm 59 in North America power cable ...

Page 128: ...epth rack 424 2 mm maximum travel length 2 3 extension from rack 130 lbs 59 Kgs max support weight Tool less chassis attach Tools required to attach to rails to rack Note No cable management arm support 1U Premium quality rails with no CMA support iPC A1USHRTRAIL MM 939208 UPC 00735858289931 EAN 5032037068772 MOQ 1 Product type 1U accessory kit Travel distance 780 mm Adjustment within 609 6 mm 762...

Page 129: ... 939210 UPC 00735858291996 EAN 5032037070553 MOQ 1 Product type 2U accessory kit Travel distance 788 mm Adjustment within 594 8 mm 813 mm to fit difference depth rack Bracket adjustment from 594 8mm to 813mm Tool less installation Supports up to 45Kg Full extension from rack Kit includes Rails screws installation manual 1U 2U 2 Post fixed mount bracket kit iPC AXX2POSTBRCKT MM 918808 UPC 007358582...

Page 130: ...mily Configuration Guide 130 Image Details Description Image Pending Cable Management Arm CMA iPC AXXCMA2 MM 939211 UPC 00735858292009 EAN 5032037070560 MOQ 1 Product type 2U accessory kit Compatible with Premium 2U AXXFULLRAIL only ...

Page 131: ... A2UHANDLKIT MM 936038 UPC 00735858288866 EAN 5032037068147 MOQ 1 Product type 2U drive upgrade kit 1U 2U spares kit This kit includes 3 different rack handles including 1 Set of 2U storage rack handles with control panel and USB support R2312WFxxxx R2224WFxxxx 1 Set of 2U non storage rack handles R2208WFxxxx R2208WFxxxx 8 Drive Accessory Kit 1 Set of 1U rack handles R1304WFxxxx R1208WFxxxx This k...

Page 132: ...C8 MM 955867 UPC 00735858345712 EAN 5032037106207 MOQ 1 Product type 1U 2U accessory kit A TPM is a hardware based security device that addresses the growing concern on boot process integrity and offers better data protection TPM protects the system start up process by ensuring it is tamper free before releasing system control to the operating system A TPM device provides secured storage to store ...

Page 133: ...ot compatible with R2312WFxxx systems 4 Port PCIe x8 Switch Add In Card iPC AXXP3SWX08040 MM 958241 UPC 00735858345620 EAN 5032037106115 MOQ 1 Product type 1U 2U accessory kit This switch add in card is used to increase the number of PCIe SSD drives within the system by 4 The 4 drive switch is a low profile MD2 form factor PCIe card Additional required accessory The following cable kit is required...

Page 134: ...the OCP module bay of either the 1U or 2U chassis All required signals power for the board are passed through the included sideband cable Kit includes 1 IFT Carrier Mezzanine Board iPN H88405 xxx 1 235 mm cable iPN H79272 xxx 1 port Mezzanine card to Fabric Processor 1 1 430 mm cable iPN H77497 xxx 2x12 HFI Sideband Y Cable Single Intel Omni Path Sideband IFT Carrier to dual Intel Omni Path CPU co...

Page 135: ...sor support Dual Fabric processor configurations require the following additional accessory kits to be ordered separately Cable kit AXXCBL235IFPR1 235mm cable iPN H79272 xxx PCIe Add in card to Fabric Processor 2 Fabric Processor Clip Kit FXXCPUCLIPF Used to attach fabric enabled processor to processor heat sink Important This product is only compatible with external Intel Omni Path passive cables...

Page 136: ...l Xeon Phi cards with active heat sinks are NOT supported in systems confgured with the high airflow air duct Note Systems configured with any type of Intel Xeon Phi card and or non Intel GPGPU card must have the shipping bracket installed before the system is exposed to any level of shock or vibration or is shipped to the end user location Failure to install the shipping bracket has the potential...

Page 137: ...pt R2224 and R2312 Includes one front panel board 1U Spare Fan Assembly 3 Fans iPC FR1UFAN10PW MM 974906 UPC 00735858283342 EAN 5032037064408 MOQ 1 Product type 1U spare FRU Three spare fans for R1000WF systems as an assembly 40x56 mm dual rotor with 10p connector Includes three fans in the bracket with grommets preinstalled 2U Spare Fan 2 Fans Kit iPC FR2UFAN60HSW MM 934990 UPC 00735858283359 EAN...

Page 138: ...32037068093 MOQ 1 Product type 2U spare FRU Hot swap backplane board spare for R2308 systems Includes one backplane board 8x2 5 SAS NVMe Hot Swap Backplane iPC F2U8X25S3PHS MM 955870 UPC 00735858344913 EAN 5032037105620 MOQ 1 Product type 2U spare FRU Combination hot swap backplane board spare supporting SAS and NVMe drives in the R2208 systems Includes one backplane board 12x3 5 SAS and 2x NVMe H...

Page 139: ...tandard chassis rack handles must be replaced with a pair of storage rack handles that include the system front panel and front USB 2 0 port See the appropriate Intel Server System Product Family System Integration and Service Guide for complete system integration upgrade and part replacement instructions Note The 2U storage rack handles are not supported on R2312WFTF systems 2 5 Tool Less Hot Swa...

Page 140: ...erformance of Intel Quick Sync Video Full complement of bare metal operating systems for the onboard Intel Xeon processor E3 1500 v5 nodes for application software support across multiple market segments CentOS 7 x Windows 10 Windows Server 2016 PCIe x8 to each of the three on board Intel Xeon processor E3 1500L v5 nodes supports highly bandwidth intensive media ingest Multiple 1U and 2U server sy...

Page 141: ...sors or memory KDK Knock Down Kit Chassis only product KVM Keyboard Video Mouse MM Master Material order number MOQ Minimum Order Quantity NVMe NVM Express based on Non Volatile Memory Host Controller Interface Specification NVMHCI ODD Optical disk drive Intel OP HFI Intel Omni Path Host Fabric Interface Optional Accessory Hardware that can be added to the system to enhance the default feature set...

Page 142: ...Attached SCSI SATA Serial ATA SFF NVMe NVMe SSD in a 2 5 form factor SFP Small Form factor Pluggable SKU Stock Keeping Unit SSD Solid State Drive TPM Trusted Platform Manager UPC Universal Product Code Barcode Intel VCA Intel Visual Compute Accelerator Intel VROC Intel Virtual RAID on CPU ...

Reviews: