6
Intel® Management Module Installation and User’s Guide
Advanced Edition Features
The Advanced Edition adds all the features listed above for the Professional Edition, plus the
following features:
•
BMC-resident SNMP support for out-of-band access using 3
rd
party applications such as
Hewlett-Packard* OpenView*
•
Embedded web server to access system health, view the SEL, and issue IPMI commands
•
Embedded Command Line Interface (using a Telnet server running on the BMC) to allow
direct terminal access to the BMC
•
Alerting via Email
•
Intel
®
Advanced Remote Server Control adds remote KVM functionality
•
High-speed access to a dedicated NIC for the BMC on the Advanced Edition module
The Intel Advanced Remote Server Control, email alerting, embedded CLI, embedded web,
BMC-resident SNMP agent, SOL, and other firmware-resident features are available Out-of-Band
(OOB). This means that these features are available even when the Operating System is not
running or the AC power is off.
Getting the Latest Information and Support
The latest information on each server board and Intel software is available at:
http://support.intel.com/support/motherboards/server
Platform Compatibility and System Requirements
The Intel Management Modules are compatible with the following Intel server boards:
•
Intel Server Board SE7520AF2
•
Intel Server Board SE7520BD2
•
Intel Server Board SE7520JR2
•
Intel Server Board SE8500HW4
Table 1 on page 7 lists the minimum system requirements.