Intel® Server System M70KLP Family Service Guide
22
2.3.1
Cable Management Brackets
Mounted to each chassis sidewall are two cable management brackets as shown in the following figure.
Figure 17. Internal Cable Management
2.3.2
System Fan Housing
–
Removal / Installation
To route cables to/from the area behind the front drive bay, the system fan housing must be removed from
the chassis. The fan housing is modular allowing for tool-less removal and installation.
2.3.2.1
Fan Housing Removal
1.
(If installed) Remove the system air duct from the chassis (see
Section 2.1.2
).
Figure 18. System Fan Removal
2.
Remove all 6 system fans from the fan housing.
•
Using the finger grips atop of each system fan, squeeze and pull each fan up from the housing.
Open bracket to install cables
Close bracket to secure cables
Cables routed and secured