Intel® Server System M20NTP1UR - System Integration and Service Guide
82
•
Align the Pin 1 indicators of the processor carrier clip and processor with the Pin 1
indicator on the socket assembly bolster plate.
18.
Install the fully assembled PHM onto the processor socket (See
Figure 107. PHM Installation onto Server Board
•
Set all four anti-tilt wires on the heat sink to the inward position (see Letter “A”).
•
Carefully lower the PHM over the four bolster plate alignment pins (see Letter “B”).
•
Ensure the PHM is sitting flat and even on the bolster plate.
•
Set all four anti-tilt wires on the heat sink to the outward position (see Letter “C”).
19.
Secure the PHM to the bolster plate
Figure 108. Tighten Heat Sink Fasteners
•
Using a T30 Torx* screwdriver, tighten the heat sink fasteners to 8 in-lb.
Summary of Contents for M20NTP1UR
Page 2: ...2 This page intentionally left blank...
Page 101: ...Intel Server System M20NTP1UR System Integration and Service Guide 101 1 2 3 4 5...
Page 102: ...Intel Server System M20NTP1UR System Integration and Service Guide 102 1 2 3 4 5 6 1 2 3...
Page 103: ...Intel Server System M20NTP1UR System Integration and Service Guide 103 1 2 3 4 5...
Page 112: ...Intel Server System M20NTP1UR System Integration and Service Guide 112 1 2 3 4 5 ESD 6 1 2 3...
Page 113: ...Intel Server System M20NTP1UR System Integration and Service Guide 113 1 2 3 4 5...