Intel® Server System M20NTP1UR - System Integration and Service Guide
78
9.
Carefully dis-assemble the PHM (See
Figure 98. PHM Disassembly
•
While holding down the PHM, rotate the lever (see Letter “A”) clockwise until the processor
lifts free from the processor carrier clip.
•
While holding down the edges of the processor carrier clip, carefully lift out the processor (see
Letter “B”).
10.
Return the lever to its original position and detach the processor carrier clip from the heat sink. (See
Figure 99. Processor Carrier Clip Removal from PHM Assembly
•
Unlatch the hook on each corner of the processor carrier clip and lift it from the heat sink
(see Letter “D”).
To properly reassemble the PHM and install it onto the server board, the procedures described in the
following steps must be followed in the order specified. These instructions assume that the processor heat
sink (New or reuse of existing) has the necessary Thermal Interface Material (TIM) (DOWSIL* TC-5888)
already applied.
Note:
Full ESD precautions should be followed to perform reassembly of the PHM and reinstallation of the
PHM to the server board. At no time should the processor itself be handled.
Summary of Contents for M20NTP1UR
Page 2: ...2 This page intentionally left blank...
Page 101: ...Intel Server System M20NTP1UR System Integration and Service Guide 101 1 2 3 4 5...
Page 102: ...Intel Server System M20NTP1UR System Integration and Service Guide 102 1 2 3 4 5 6 1 2 3...
Page 103: ...Intel Server System M20NTP1UR System Integration and Service Guide 103 1 2 3 4 5...
Page 112: ...Intel Server System M20NTP1UR System Integration and Service Guide 112 1 2 3 4 5 ESD 6 1 2 3...
Page 113: ...Intel Server System M20NTP1UR System Integration and Service Guide 113 1 2 3 4 5...