Intel® Server System M20NTP1UR - System Integration and Service Guide
59
5.
Install the fan into the system (See
Figure 63. System fan assembly installation
•
Carefully position and install the replacement fan into the fan assembly, ensuring all rubber
guides are in place and the fan cable is located on the side closest to the server board.
•
Attach the fan cable to the fan connector on the server board. Ensure that no cables are trapped
beneath the fan module (see Letter “B”).
6.5
Power Supply Replacement
Required Tools and Supplies
•
Intel spare power supply kit – iPC
AXXBFP750SLPS
•
Anti-static wrist strap and conductive workbench pad (recommended)
Note
: Power supply modules can only be hot-swapped when the system is operating in a 1+1 redundant
power configuration.
1.
Detach the AC power cord from the faulty power supply module
2.
Remove the power supply from the system (See
Figure 64. Power Supply Removal
•
Push and hold the green latch in the direction shown (see Letter “A”).
•
Use the handle to pull the power supply module from the system (see Letter “B”).
Summary of Contents for M20NTP1UR
Page 2: ...2 This page intentionally left blank...
Page 101: ...Intel Server System M20NTP1UR System Integration and Service Guide 101 1 2 3 4 5...
Page 102: ...Intel Server System M20NTP1UR System Integration and Service Guide 102 1 2 3 4 5 6 1 2 3...
Page 103: ...Intel Server System M20NTP1UR System Integration and Service Guide 103 1 2 3 4 5...
Page 112: ...Intel Server System M20NTP1UR System Integration and Service Guide 112 1 2 3 4 5 ESD 6 1 2 3...
Page 113: ...Intel Server System M20NTP1UR System Integration and Service Guide 113 1 2 3 4 5...