Intel® Server System M20NTP1UR - System Integration and Service Guide
22
2.3.1
PHM Assembly
To properly assemble the PHM and install it onto the server board, the procedures described in the following
sections must be followed in the order specified. These instructions assume that the processor heat sink has
the necessary Thermal Interface Material (TIM) (DOWSIL* TC-5888) already applied.
Note:
Full ESD precautions should be followed to perform assembly of the PHM and its installation to the
server board. At no time should the processor itself be handled.
Each component within the PHM assembly includes a Pin 1 indicator. Pin 1 indicator alignment between all
components is required throughout the assembly process.
1.
Orient and align the processor carrier clip to the processor (See Figure 9)
Figure 9. Installing Processor Carrier Clip onto Processor – Part 1
•
With the processor still in its tray, place the processor carrier clip over the processor.
•
Ensure the Pin 1 indicator on the processor carrier clip is aligned with the Pin 1 indicator of
the processor.
2.
Attach the Processor Carrier Clip to the Processor (See Figure 10)
Figure 10. Installing Processor Carrier Clip onto Processor – Part 2
•
Gently press down simultaneously on two opposite sides of the processor carrier clip until it
clicks in place. Repeat with the other two sides.
Summary of Contents for M20NTP1UR
Page 2: ...2 This page intentionally left blank...
Page 101: ...Intel Server System M20NTP1UR System Integration and Service Guide 101 1 2 3 4 5...
Page 102: ...Intel Server System M20NTP1UR System Integration and Service Guide 102 1 2 3 4 5 6 1 2 3...
Page 103: ...Intel Server System M20NTP1UR System Integration and Service Guide 103 1 2 3 4 5...
Page 112: ...Intel Server System M20NTP1UR System Integration and Service Guide 112 1 2 3 4 5 ESD 6 1 2 3...
Page 113: ...Intel Server System M20NTP1UR System Integration and Service Guide 113 1 2 3 4 5...