Introduction 

Revision 1.3 

  

 

 

3

1.1.2.1 

Support Commitment for Adapter / Peripheral Compatibility and Stress 
Testing 

Intel commits to provide the following level of customer support for operating systems that 
receive Adapter / Peripheral Compatibility and Stress testing: 

 

Intel will provide support for customer issues with these operating systems involving 
installation and/or functionality of the server board with or without the adapters and 
peripherals listed in this document as having been tested under the particular operating 
system. 

 

Support is defined as assistance in root causing issues, and determining a customer 
acceptable resolution to the issue associated with the operating system.  The resolution 
may include, but is not limited to, on-board controller driver changes, engaging the 
vendor for resolution, BIOS changes, firmware changes, or determining a customer 
acceptable workaround for the issue. 

 

Intel will provide and test operating system drivers for each onboard video, network, and 
storage controller.   

 

Intel will enable vendors to provide driver support for add-in adapters using these 
operating systems. 

 

Intel will go through some of the steps to achieve certification to ensure its customers do 
not run across any problems, but the actual certification is the responsibility of the 
individual customer.     

   

For operating systems, adapter cards, and peripherals not listed in this 
document, there is no support commitment.  Intel will consider support requests 
on a case-by-case basis. 

 

1.2  Pass/Fail Test Criteria 

For each operating system, adapter, and peripheral configuration, a test passes if specific 
criteria are met.  Specific configurations may have had particular characteristics that were 
addressed on a case-by-case basis.  In general, a configuration passes testing if the following 
conditions are met: 

  The operating system installed without error. 

  Manufacturer’s installation instructions or Intel’s best-known methods were used for the 

operating system installation. 

  No extraordinary workarounds were required during the operating system installation. 

  The server system behaved as expected during and after the operating system 

installation. 

  Application software installed and executed normally. 

  Hardware compatibility tests ran to completion without error. 

  Test software suites executed successfully 

  Test and data files were created in the correct directories without error. 

  Files copied from client to server and back compare to the original with zero errors 

reported. 

  Clients remain connected to the server system. 

  Industry standard test suites run to completion with zero errors reported. 

 

Summary of Contents for IP Network server NSI2U

Page 1: ...Intel Carrier Grade Server TIGI2U Intel IP Network Server NSI2U Tested Hardware and Operating System List Revision 1 3 September 2006 Enterprise Platforms and Services Marketing...

Page 2: ...ducts Intel assumes no liability whatsoever and Intel disclaims any express or implied warranty relating to sale and or use of Intel products including liability or warranties relating to fitness for...

Page 3: ...tems Supported but not Tested 6 3 2 Operating System Certifications 6 4 Adapters and Peripherals 8 4 1 PCI SCSI RAID 10 4 2 PCI SATA RAID 10 4 3 PCI SCSI 11 4 4 PCI MROMB 12 4 5 PCI Fibre Channel 12 4...

Page 4: ......

Page 5: ...following server building blocks and integrated systems Product Code Product Description TLIA0201 Intel Carrier Grade Server TIGI2U Server Board SE7520JR2 Onboard SCSI DDR2 400 MHz Two PCI Risers 20...

Page 6: ...ning a customer acceptable resolution to the issue associated with the operating system The resolution may include but is not limited to on board controller driver changes engaging the vendor for reso...

Page 7: ...tomers do not run across any problems but the actual certification is the responsibility of the individual customer For operating systems adapter cards and peripherals not listed in this document ther...

Page 8: ...in this family of products This table is updated when a new test run is performed and a new product system software combination was used Intel will only provide support for adapters and peripherals un...

Page 9: ...Intel s best known methods Operating systems supported by Intel Server Management software or LANDesk Client Manager software may be different than the operating systems supported by the Intel Server...

Page 10: ...ystem Certifications Listed below are the operating systems that Intel will certify with the Intel Carrier Grade Server TIGI2U and the Intel IP Network Server NSI2U However the customer is responsible...

Page 11: ...http bugzilla redhat com hwcert show cgi id 1648 44 TIGI2U Server http bugzilla redhat com hwcert show cgi id 1802 63 SuSE Linux Enterprise Server 9 Service Pack 1 SuSE Linux Enterprise Server 9 Servi...

Page 12: ...is supported but not tested This adapter is supported but not tested This adapter model has not been tested with this server board but Intel will support it based on successful testing of a similar ad...

Page 13: ...ormed with unused add in adapters and onboard controller expansion ROMs disabled in BIOS Setup Intel recommends that customers disable the option ROM for add in controllers and or the on board control...

Page 14: ...314G 1 2 2 1 2 1 2 Intel SRCU42E Rumley PCI E x8 BIOS H423 FW 514F 2 2 2 2 Intel SRCU42L SRCU42L PCI 64 66 BIOS 7 05C FW 2 42 02 R07A 2 3 2 3 2 3 2 3 Intel SRCU42X SRCU42X PCI X133 BIOS H424 FW 413Z 1...

Page 15: ...l SRCS28X SRCS28X PCI X133 BIOS H425 FW 813G 2 2 2 2 LSI Logic MegaRAID SATA 150 6 MegaRAID SATA 150 6 PCI 64 66 BIOS G119 FW 713N 2 3 2 3 2 3 2 3 LSI Logic MegaRAID SATA 150 4 MegaRAID SATA 150 4 PCI...

Page 16: ...c LSI20160L LSI20160L PCI 32 33 SA SA SA SA LSI Logic LSI22320 R LSI22320 R PCI X133 BIOS 5 10 03 FW 1 3 39 1 2 3 2 3 1 2 3 1 2 3 LSI Logic LSI20320 R LSI20320 R PCI X133 Similar Adapter LSI22320 R SA...

Page 17: ...BIOS 2 02 00 FW 1 02 02 2 2 2 2 LSI Logic LSI7102XP LC LSI7102XP LC PCI X133 Similar Adapter LSI7202XP LC SA SA SA SA LSI Logic LSI7402XP LC LSI7402XP LC PCI X133 Similar Adapter LSI7202XP LC SA SA S...

Page 18: ...8490XT SA SA SA SA Intel PWLA8490XTL PRO 1000XTL Gigabit Server Adapter PCI X133 Similar Adapter PWLA8490XT SA SA SA SA Intel PWLA8492MT PRO 1000MT Dual Port Gigabit Server Adapter PCI X133 2 3 2 3 1...

Page 19: ...33 0121 Internet Navigator PS 2 and USB Keyboard 1 2 2 1 2 1 2 LOGITECH 967233 0403 Internet Navigator PS 2 and USB Similar Adapter 967233 0121 SA SA SA SA 4 9 CDROM Drives IBM 22P6991 24x10x24 IDE Sl...

Page 20: ...NT 1 1 Sony CRX835 L1 CRX835 L1 ATA33 Teac DV 28E BP3 DV 28E BP3 ATA33 1 2 2 1 2 1 2 Teac DW 224E C98 DW 28E C98 ATA33 3 4 Teac DV W28EA 593 DV W28EA 593 ATA33 3 4 4 11 Tape Drives Certance STD2401LW...

Page 21: ...0 Intel EM64T Edition Red Hat Enterprise Linux 3 0 Red Hat Enterprise Linux 4 0 Red Hat Enterprise Linux 3 0 Intel EM64T Edition SuSE Linux Enterprise Server 9 SuSE Linux Enterprise Server 9 4 13 KVM...

Page 22: ...fication number Number in brackets i e 1 This hard drive has been tested but is NOT supported under the operating system identified by the operating system identification number SD Similar Drive The h...

Page 23: ...300GB 1 3 Hitachi HUS103014EL3 800 Ultrastar 10K300 SCSI U320 10 000 147GB 1 3 Hitachi HUS103073EL3 800 Ultrastar 10K300 SCSI U320 10 000 73GB 1 3 Hitachi HUS103036EL3 800 Ultrastar 10K300 SCSI U320 1...

Page 24: ...ta 15K 4 SCSI U320 15 000 73GB 1 2 3 4 Seagate ST336754LC Cheeta 15K 4 SCSI U320 15 000 36GB 5 3 7 3 SD Seagate ST3146854LC Cheeta 15K 4 SCSI U320 15 000 146GB SD Serial ATA SATA Hard Drives Hitachi H...

Page 25: ...Manufacturer Model Number Product Family Interface RPM Drive size GB Tested Operating Systems Notes Western Digital WD360GD WD Raptor SATA 150 10 000 36GB SD Note Blue shading indicates that the adapt...

Page 26: ...n ROM utility Ctrl M for the following LSI adapters MegaRAID 320 2 MegaRAID 320 1 MegaRAID 320 0 MegaRAID SATA 150 6 MegaRAID SATA 150 4 and older U160 SCSI MegaRAID adapters Guideline BIOS P07 20 or...

Reviews: