Intel® Server D50TNP Family Integration and Service Guide
22
2.
L6 Integrated System – Essential System Component
Installation
The Intel® Server System D50TNP modules are offered with different levels of system integration. System
modules that are not power-on ready are identified as L6 integrated modules; L6 modules require essential
components (sold separately) to be installed. If your Intel D50TNP module did not come pre-installed with
any of the following components, follow the procedures in this chapter:
•
2 processors
–
3
rd
Gen Intel® Xeon® Scalable processors
•
Memory
–
Up to 16 DDR4 DIMMs for D50TNP1MHCRAC, D50TNP1MHCRLC and D50TNP1MHEVAC,
and up to 16 DDR4 + 8 Intel® Optane
™
persistent memory 200 series DIMMs for all other modules.
If your Intel D50TNP module came pre-installed with all the components listed above, skip this chapter and
go to
Chapter 3
for installation procedures associated with all other system options and accessories.
To complete the L6 integration of the D50TNP Intel® Server System to be power-on ready, a chassis from
Intel® Server chassis FC2000 family is required to house the L6 integrated modules. The chassis for L6
systems is sold separately and comes with 1600 W or 2100 W power supply units pre-installed.
Each module within a system configuration is independently operated from the others. The Installed
modules within a system chassis share resources like power and cooling.
describes the different
ways an Intel® Server System D50TNP can be configured.
For additional information regarding configuration options, see the
Intel® Server System D50TNP Family
Configuration Guide
.
Table 2. Intel® D50TNP Module Family
Module Type
iPC
Height
Width
Cooling
Maximum Processor
Thermal Design
Power (TDP)
Modules per
Chassis
Compute
D50TNP1MHCPAC
1U
Half width
Air cooled
205 W
Up to four
D50TNP1MHCRAC
205 W
D50TNP1MHEVAC
(Q3 2021)
270 W
D50TNP1MHCRLC
Liquid cooled
270 W
Up to four
Management
D50TNP2MHSVAC
2U
Half width
Air cooled
270 W
Up to two
Storage
D50TNP2MHSTAC
(Q3 2021)
2U
Half width
Air cooled
205 W
Up to two
Accelerator
D50TNP2MFALAC
2U
Full width
Air cooled
270 W
One
Mixing different types of modules in the same chassis can be done as follows:
•
Up to two 1U air-cooled Compute Modules with one 2U Management Module
•
Up to two 1U air-cooled Compute Modules with one 2U Storage Module
•
One 2U Management Module with one 2U Storage Module
Before You Begin
Before integration of any system components, review all the safety and ESD precautions found in the Safety
Warnings section at the beginning of this guide.