
Error Messages and Indicators
83
Table 38.
BIOS Error Messages (continued)
Error Message
Explanation
Memory Size Decreased
Memory size has decreased since the last boot. If no memory was
removed, then memory may be bad.
Memory Size Increased
Memory size has increased since the last boot. If no memory was
added, there may be a problem with the system.
Memory Size Changed
Memory size has changed since the last boot. If no memory was
added or removed, then memory may be bad.
No Boot Device Available
System did not find a device to boot.
Off Board Parity Error
A parity error occurred on an offboard card. This error is followed
by an address.
On Board Parity Error
A parity error occurred in onboard memory. This error is followed
by an address.
Parity Error
A parity error occurred in onboard memory at an unknown
address.
NVRAM / CMOS / PASSWORD
cleared by Jumper
NVRAM, CMOS, and passwords have been cleared. The system
should be powered down and the jumper removed.
<CTRL_N> Pressed
CMOS is ignored and NVRAM is cleared. User must enter Setup.
Summary of Contents for C70847-001
Page 1: ...Intel Desktop Board D865GVHZ Product Guide Order Number C70847 001...
Page 46: ...Intel Desktop Board D865GVHZ Product Guide 46...
Page 50: ...Intel Desktop Board D865GVHZ Product Guide 50...
Page 78: ...Intel Desktop Board D865GVHZ Product Guide 78...
Page 84: ...Intel Desktop Board D865GVHZ Product Guide 84...