Thermal Metrology
R
Intel
®
848P Chipset Thermal Design Guide
19
3.3 Airflow
Characterization
Figure 7 describes the recommended location for air temperature measurements measured relative to
the component. For a more accurate measurement of the average approach air temperature, Intel
recommends averaging temperatures recorded from two thermocouples spaced about 25 mm
[1.0 in] apart. Locations for both a single thermocouple and a pair of thermocouples are presented.
Figure 7. Airflow Temperature Measurement Locations
Airflow velocity should be measured using industry standard air velocity sensors. Typical airflow
sensor technology may include hot wire anemometers. Figure 7 provides guidance for airflow
velocity measurement locations. These locations are for a typical JEDEC test setup and may not be
compatible with chassis layouts due to the proximity of the processor to the MCH. The user may
have to adjust the locations for a specific chassis. Be aware that sensors may need to be aligned
perpendicular to the airflow velocity vector or an inaccurate measurement may result. Measurements
should be taken with the chassis fully sealed in its operational configuration to achieve a
representative airflow profile within the chassis.