100Base-TX Transmit Jitter
1000BASE-T/100BASE-TX/10BASE-T Physical Layer Compliance Tests Manual
58
Intel Confidential
Figure 14-1. Test Setup 1
2. From the 100 BASE-TX PHY Configuration Tests menu, select the Jitter: 9.1.9 test
3. Configure the oscilloscope according to the
.
4. Scroll horizontally until an eye pattern is found similar to that shown in
Figure 14-2. Transmit Jitter Data
Note:
The jitter of the waveform in figure 14-2 is measured at 920ps.
5. Allow data to accumulate for one to ten minutes.
6. Use the scope’s vertical bar cursors to measure the widest “X” as shown in
7. Record the results.
8. Confirm that the resulting jitter is less than 1.4 ns.
9. Verify the measurements meet specifications.
Table 14-1. Setting for Transmit Jitter
Scope Parameter
Setting
Horizontal Scale
~500 ps/division
Vertical Range
-800 mV to +800 mV (1600 mV over the full vertical scale)
Trigger Type
Positive edge triggering
Trigger Level
500 mV
Display Type
Infinite persistence