1000BASE-T/100BASE-TX/10BASE-T Physical Layer Compliance Tests Manual
Intel Confidential
39
100Base-TX Signal Amplitude Symmetry
10 100Base-TX Signal Amplitude
Symmetry
ANSI Section 9.1.4
10.1
Test Purpose
To measure the voltage symmetry of the positive and negative waveforms.
10.2
Specification
“The ratio of the +V
OUT
magnitude to -V
OUT
magnitude shall be between the limits:
.”
1
10.3
Test Procedure
1. Perform test described in
if it has not already been done.
2. Calculate the ratio of +V
OUT
to -V
OUT
using the values from the results of
3. Record the results.
4. Verify the measurements meet specifications.
Figure 10-1. Calculating the Ratio of +V
OUT
to -V
OUT
1.
ANSI X3.263-1995, p 29.
0.98
V
OUT
V
–
OUT
-------------------- 1.02
≤
≤
From the plots in
0.98
≤
1.003
≤
1.02.
Note
: +V
OUT
and -V
OUT
have the same units (V).
1.014
V
1.011
V
-----------------
1.003
=