background image

7

HAND ORIENTATION

CORRECT PLACEMENT – TOP VIEW

Ground Bar

Fingers must point 

to cable and be 

firmly grounded 

against 

platen

 and 

ground bar

.

Platen

Summary of Contents for FIVE-0

Page 1: ...USER MANUAL...

Page 2: ...nditions Hand Orientation 7 Correct Placement Top View Finger Contact 8 Correct Placement Side View Flat Scanning 9 Finger Position Flat Scanning 10 Thumb Capture Roll Scanning 11 Finger Placement Rol...

Page 3: ...olutions FIVE 0 is the most durable highest performance FAP 50 FBI Appendix F certified ten print live scanning solution Please read this manual thoroughly before using your FIVE 0 to review proper st...

Page 4: ...ment 4 See below for connection options Download and install the latest version of the IBScanUltimate software kit SDK For proper cleaning and disinfection of IB products visit https integratedbiometr...

Page 5: ...nents demonstration applications and source code for each platform Demonstration source code is a simple reference for integrators to rapidly develop solutions using Integrated Biometrics LES technolo...

Page 6: ...ter than desired Solution Rub a small amount of moisturizer on the fingertips Do not slather The resultant images will be darker and the NFIQ quality scores will improve Gentle or light contact with t...

Page 7: ...7 HAND ORIENTATION CORRECT PLACEMENT TOP VIEW Ground Bar Fingers must point to cable and be firmly grounded against platen and ground bar Platen...

Page 8: ...8 FINGER CONTACT CORRECT PLACEMENT SIDE VIEW Ground Bar Fingers must point to cable and be firmly grounded against platen and ground bar Platen...

Page 9: ...NNING FINGER POSITION Ground Bar Platen Ready to Scan Ready to Scan Place your right hand firmly against the bezel to ensure proper contact Place your left hand firmly against the bezel to ensure prop...

Page 10: ...PTURE Ground Bar Platen Ready to Scan Place your thumbs flat against the platen and the bottom of the thumbs thumbs firmly against the bezel to ensure contact Hold the unit with your index fingers poi...

Page 11: ...ce the indicated finger firmly against the bezel and platen to ensure good contact Ground Bar Platen Ready to Scan While maintaining good contact with the platen and bezel turn your finger 45 degrees...

Page 12: ...FINGERPRINTS While maintaining good contact with the platen and bezel now turn your finger 45 degrees clockwise Place the next finger in sequence and repeat the steps above Proper Print Improperly Ro...

Page 13: ...l interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televis...

Page 14: ...atedbiometrics com WORLD CLASS TECHNOLOGY LES technology empowers energy efficient compact and durable biometric scanning solutions unique to the market Ready to deploy in any environment under any co...

Reviews: