AOM9SE2 90cm Oven Installation and Operation Manual
Electrical Connection
Ovens with a three-pole power supply cable are designed to operate with alternated
current at the supply frequency and voltage indicated on the data plate (at the
bottom of the oven dashboard). The earthing conductor of the cable is the
yellow-green conductor.
Connecting the power supply cable to the mains
The appliance must be directly connected to the mains using an omnipolar
circuit-breaker with a minimum contact opening of 3 mm installed between the
appliance and the mains, suitable for the load indicated and complying with current
directives (the earthing wire must not be interrupted by the circuit-breaker).
The power supply cable must be positioned so that it does not exceed 50
o
C more
than room temperature at any point of its length.
Before making the connection check that:
●
the circuit breaker / fuse and the home system can support the appliance load
(see data plate);
●
the power supply system has an efficient earthing connection which complies with
the provisions of current regulations;
●
the socket or omnipoar circuit-breaker is easily accessible once the cooker has
been installed.
NOTE: do not use reducers, adaptors or shunts as they could cause overheating and
burns.
- 10 -