Armaturen met 1-10V/DALI driver bedienen met een drukknop

Technische parameters

INPUT

Aansluitspanning

110-240VAC

Bediening

drukknop/Zigbee

Output 0/1-10V

Max 20mA

DALI

Max 50mA

Omgevingstemp

-20~+50°C

Luchtvochtigheid

8~80%

Afmetingen

80x36x20,5mm

Instelling

Bij het aanpassen van de DIP-switch instellingen steeds de spanning uitschakelen!

1. Kies de gewenste uitgangsmodus 1-10 of DALI

 

DALI DT6 modus (broadcast) = DIP-SWITCH 1+3+4+5+6+7+10 op ON

 

0/1-10V modus = Alle DIP-SWITCH op OFF 

ON

OFF

Aansluitschema 1-10V modus

drukknop

Aansluitschema DALI modus

drukknop

Max 

20mA

Max 50mA

(25 DALI drivers)

Bediening

Kort drukken = aan/uit

Lang drukken = dimmen

01/07/2022

Summary of Contents for SR-2421-ZG-PUSH

Page 1: ...uchtvochtigheid 8 80 Afmetingen 80x36x20 5mm Instelling Bij het aanpassen van de DIP switch instellingen steeds de spanning uitschakelen 1 Kies de gewenste uitgangsmodus 1 10 of DALI DALI DT6 modus broadcast DIP SWITCH 1 3 4 5 6 7 10 op ON 0 1 10V modus Alle DIP SWITCH op OFF ON OFF Aansluitschema 1 10V modus drukknop Aansluitschema DALI modus drukknop Max 20mA Max 50mA 25 DALI drivers Bediening K...

Page 2: ...1 2 3 4 5 6 7 8 9 10 Address Mode 1 2 3 4 5 6 7 8 3 Select DALI Address or Group Control Mode Using Dial Switch 7 Group Mode 1 2 3 4 5 6 7 8 9 9 10 DALI 1 2 3 4 5 6 7 8 1 Select DALI or 0 1 10V Output Using Dial Switch 10 0 1 10V 1 2 3 4 5 6 7 8 9 10 9 10 1 2 3 4 5 6 7 8 9 10 Dial up Dial down Note please first select output signal by the dial switch Note once DALI output is selected please then s...

Page 3: ...r TouchLink the device can be controlled by the linked remotes Step 1 Remove the device from previous zigbee network if it has already been added to otherwise pairing will fail Please refer to the part Factory Reset Manually Step 2 From your ZigBee Controller or hub interface choose to add lighting device and enter Pairing mode as instructed by the controller Step 4 LED indicator will blink 5 time...

Page 4: ... Learning mode please refer to its manual Step 3 LED indicator will flash 4 times to indicate successful deleting Step 1 Short press Prog button 3 times Or reset power of the device 3 times to start delete Learning to GP switch mode connected light flashes slowly 180 seconds timeout repeat the step Step 1 Short press Prog key for 5 times continuously or reset power of the device for 5 times contin...

Page 5: ...hen DALI Output Selected Ÿ Click the button to switch ON OFF Ÿ Press and hold down the button to increase or decrease overall light intensity of tunable white to desired level and release it then repeat the operation to adjust overall light intensity to opposite direction While connected with an AC push switch and DALI output is selected operations to control the DALI control gears are as follows ...