Overview and IFU Refresher

MAYFIELD is a registered trademark of SM USA Inc. and is used by Integra under license.

Summary of Contents for Head Clamp Pediatric Horseshoe Headrest A20114

Page 1: ...0688771 1 0688771 1 MAYFIELD Imaging Overview and IFU Refresher MAYFIELD is a registered trademark of SM USA Inc and is used by Integra under license ...

Page 2: ... Horseshoe Headrest Spine Table Adapter Jackson Table Radiolucent Skull Pins Titanium Sapphire Radiolucent Budde Halo System this system is outside the scope of this training MAYFIELD is a registered trademark of SM USA Inc and is used by Integra under license Budde is a registered trademark of Integra LifeSciences Corporation in the United States and or other countries ...

Page 3: ...mp Made of carbon filled PEEK Little or no artifact Only metal is the spring in the torque knob Metal free conversion accessory offers a completely metal free set up different torque knob Head Clamp Standard Configuration Metal Free Conversion Accessory ...

Page 4: ... 4 Skull Clamp Base or Body 5 Plunger 6 Starburst Attachment 7 Skull Clamp Ratchet Extension Accessories a XR2 Force Applicator 439A1093 included with metal free conversion kit 439A1092 b Stop Wheel c Metal free ratchet extension d XR2 Child s Rocker 439A1091 1 7 4 6 5 2 3 d b c a Head Clamp Standard Configuration Metal Free Conversion Accessory ...

Page 5: ...ne around the head clamp attachment scanning area Width adjustable 2 different sizes Item No OR Table Width s Side rail to side rail Cross Bar Width A2079 19 5in to 24in 49 6 cm to 61 cm Approx 28 A2079E 22in to 28in 55 9 cm to 71 1 cm Approx 32 Metal free zone Base Unit ...

Page 6: ...entification 1 Skull Clamp Headrest Locking Knob 2 Swivel Adaptor 3 Link Arm Locking Knobs 4 Yoke 5 Crossbar 6 Base Handle 7 Side Rail Bracket 8 Locking Lever 9 Base Handle Adjustment Knob 10 Auxiliary Side Rail 11 Side Rail Bracket Locking Base Unit ...

Page 7: ...0688771 1 0688771 1 MAYFIELD Imaging Base Unit Accessories Tri Star Swivel Adapter A2111 Extension Arms 437A2224 5 inch 437A2225 7 inch ...

Page 8: ...0688771 1 0688771 1 Pediatric Horseshoe Headrest A2011 Adult Horseshoe Headrest A2010 MAYFIELD Imaging Horseshoe Headrests Starburst to attach to standard swivel or tri star swivel adapter ...

Page 9: ...0688771 1 0688771 1 MAYFIELD Imaging Horseshoe Headrests Metal free zone Using the Spine Table Adapter with the Jackson Table Spine Table Adapter A2600R ...

Page 10: ...0688771 1 0688771 1 MAYFIELD Imaging Radiolucent Products XR2 Instructions for Use Refresher 10 ...

Page 11: ...ging Base Unit Locking Handle with Locking Lever Std Swivel Adaptor Blue ring Link Arm Yellow ring Base Handle Adjustment Knob Review of Components Tri Star Swivel Adaptor Blue ring Available as an Accessory Side Rail Rail end bracket ...

Page 12: ...ed and the locking handles unlocked hold the base unit as shown for attachment to the OR Table grasp the side rails on the end brackets with each hand Second Locking handles are unlocked opening up First Rail end bracket toggle locks are loosened to allow easy attachment to the table side rails Safety Latch ...

Page 13: ...0688771 1 0688771 1 Refresher on Instructions for Use Step 2 Slide the base unit brackets onto the side rails of the operating room table Note that locking handles are opening up and NOT DOWN ...

Page 14: ...ecurely to side rails Cautions Keep finger clear of hinge points when closing the base unit locking levers It is recommended that the levers be closed using the palm of the hand Always be sure the locking mechanisms are secure after completing table adjustments Verify that the locking lever is secure by confirming that the safety latch is engaged ...

Page 15: ...0688771 1 0688771 1 Refresher on Instructions for Use Step 4 Attaching the Link and Adaptor to the Base Unit Assembly Note the color coded sleeves Line them up yellow to yellow blue to blue ...

Page 16: ...ned to await attachment of the skull clamp Locking handles are unlocked Link and swivel adaptor are connected but not tightened for easy movement and attachment to the skull clamp Note The head section of the OR table can be attached prior to the patient entering the OR ...

Page 17: ...er 1 Attach swivel adaptor to skull clamp 2 Lock both locking handles Use an Open Palm to close handles Make certain that the locking levers are engaged 3 Tighten Swivel Adaptor knob Blue 4 Tighten Link attachment Yellow 5 Double check all connections for being tight and secure double check does not mean double tighten Link torque knob Locking Handle Swivel Clamp Torque Knob Link Swivel Torque Kno...

Page 18: ...0688771 1 0688771 1 Refresher on Instructions for Use Step 7 With the system now locked and ready confirm that all knobs and levers are locked and secure ...

Page 19: ...Knobs should not be overtightened Over tightening the mechanisms adjustment screws may result in damage to the unit Please remember that overextending or overloading the base unit may result in unintended movement shortened product life and or damage to the unit ...

Page 20: ...0688771 1 0688771 1 Always Remember The Indications for Use Warnings and Cautions ...

Page 21: ...0688771 1 0688771 1 Questions ...

Page 22: ...0688771 1 0688771 1 Thank you ...