First Time:  

CHARGE BATTERIES FOR 6 HOURS BEFORE CONNECTING YOUR EQUIPMENTS TO UPS 

 

 
3. INSTALATION 

 
 

 
 

 

This product leaves factory with battery fully charged, however during transportation and storage it may loose a 

non determined part of its charge; therefore we recommend plugging it to Power Line for 6 hours before using the 
UPS. 

 

Install this unit in any protected environment with a dust free air flow. Also corrosive vapours and conductive 

contaminants must be avoided. Do not use UPS outdoors or where either temperature or humidity exceeds tech 
specs. Install UPS at least 10 inches away from your monitor to avoid magnetic interference. 

 

1.- Plug input AC power cord to an appropriate power outlet with Line-Neutral-Ground contacts.  

 
2.-  First time leave UPS recharging batteries during 6 hours  before connecting your devices to the UPS  to  let 

batteries recover charging level to offer full battery backup time. 
 

3.- Connect your devices to be protected to UPS outlets. Take care to not overload UPS output by connecting 
devices with higher power ratings than UPS power capacity. Laser printers, scanners and copiers frequently have 

two  different  power  ratings:  in  stand-by  power  ratings  are  very  low  compared  with  consumption  rating  during 
operation. If this kind of products will be connected to the UPS operation power rating must be considering to size 

total power consumption to be connected to UPS. 
 

4.- EPO Function: Emergency Power Off function allows to power off UPS outlets when EPO input is open. When 
EPO port is closed EPO function is disable. When EPO function is activated UPS will perform following actions: 

 
a) Power Off all outlets,  

b) Switch to STAND-BY mode, 
c) Acoustic alarm is activated as continuous beep 

d) Warning message Nº 20 is indicated on LCD. 
To disable EPO mode and recovering normal mode contact switch or jumper in EPO port must be closed and UPS 

must be powered On by selecting ON push button. 
 

 
EXTERNAL BATTERIES OPTION 

EPRO models  with  EX  mark  (like  EPRO  3K-EX or  EPRO-RACK 3K-EX) are able  to be  connected  to external 
battery cabinets (EX-BATT) to offer longer backup times. 

This kind of models has internal batteries as other EPRO models but they can also be connected at any moment 
to EX-BATT supplied by INTEGRA. 

Special cables to connect EX-BATT to UPS are supplied inside the box of EX-BATT. 

 

INSTRUCTIONS TO CONNECT EXTERNAL BATTERIES 

1)

 

Place EX-BATT case close to UPS. Only INTEGRA approved EX-BATT can be connected to UPS EX 

series. 

2)

 

Check DC breakers are in OFF position (circuit OPEN)  

3)

 

Connect UPS to first EX-BATT using INTEGRA approved DC cable. 

4)

 

If more than one EX-BATT will be connected, then connect first EX-BATT to second EX-BATT and so 

on in that way to other EX-BATT. 

5)

 

After all EX-BATT are connected, switch to ON position all DC breakers located in EX-BATT. 

 

 

Summary of Contents for EPRO-Rack1K-3K

Page 1: ...________________________________________________________________________________ 091214_Sp Integra EPRO 1K 3K 1 USER MANUAL ONLINE DOUBLE CONVERSION UPS User Manual 220V Europe Schuko Zone 110V Americ...

Page 2: ...onnect this UPS to any of its own power outlets WARNING UPS must be installed following instruction from this manual The manufacturer is not liable for any damage that might rise from misusing this un...

Page 3: ...patibility levels for low frequency conducted disturbances and signaling in public low voltage power supply systems EN 61000 4 6 2006 EN 61000 4 8 2001 EN 61000 4 11 2004 EPRO EPRO RACK 2 0KVA 3 0KVA...

Page 4: ...EUROPE Zone 1 1 Programmable Outlets 2 Standard Outlets 3 AC Input 4 Input Breaker 5 Protected LAN network jacks 6 EPO Emergency Power Off 7 USB port 8 RS 232 port 9 Intelligent Slot for SNMP LAN car...

Page 5: ...ANEL 120V AMERICA 1 Programmable Outlets 2 Standard Outlets 3 AC Input 4 Input Breaker 5 Protected LAN network jacks 6 EPO Emergency Power Off 7 USB port 8 RS 232 port 9 Intelligent Slot for SNMP LAN...

Page 6: ...Auto Test function OFF ENTER a POWER OFF UPS Keep pushed for 2 seconds to power off UPS b ENTER Enter function works under configuration mode only It works as confirmation or selection key for accepti...

Page 7: ...operation If this kind of products will be connected to the UPS operation power rating must be considering to size total power consumption to be connected to UPS 4 EPO Function Emergency Power Off fun...

Page 8: ...208Vac 220Vac 230Vac 240Vac d Output Frequency It can be selected to 50Hz or 60Hz Default configuration allows auto selection to match with frequency of input AC source NOTE When conversion frequency...

Page 9: ...om AC input and UPS only switch to battery mode when input is out of range or in black out status Transition time from ECO mode to Battery mode is not zero Typically is about 4ms that is why ECO Mode...

Page 10: ...ammable Outputs Indicates programmable function is activated Operation Mode Indicates UPS is connected to input AC source under normal range Indicates UPS is in battery mode Indicates UPS is in BYPASS...

Page 11: ...s Battery Low 1 Beep per second Output Overload 2 Beeps per second UPS Failure Continuous Beep By Pass Mode 1 Beep every 10 seconds 7 LCD TEXT MESSAGES TEXT LCD TEXT Meaning ENA Enable DIS Disable ESC...

Page 12: ...ion key Enter ON Mute is used to select upper option in menu SELECT is used to select bottom option in menu Configuration Menu 00 Initial Menu Quit option 01 Output Voltage 02 CF Frequency Conversion...

Page 13: ...battery mode BAT 50 50Hz BAT 60 60Hz If CF function is enable output frequency can be set in normal mode CF 50 50Hz CF 60 60Hz 04 ECO Enable or Disable ENA ECO enable ON DIS ECO disable OFF 05 ECO In...

Page 14: ...e outlets 9 LCD screens depending of Operation Mode Operation Mode Description LCD ONLINE UPS ON Input AC source OK UPS output generated by inverter ECO UPS in ON ECO mode activated Input AC source is...

Page 15: ...MUTE SELECT at same time STAND BY UPS is OFF No power in UPS outlets Input AC source is OK Batteries are been charged 10 ERROR FAILURE CODES ON LCD FAILURE ERROR CODE ICON Bus failure 01 Hi BUS Volta...

Page 16: ...s Battery charger problem 1 s Input out of range in bypass mode 1 s 12 TROUBLESHOOTING TABLE Problem Description Probable Root Cause Suggested Action LCD does not show input voltage value AC input fa...

Page 17: ...onnel Code 28 Active Continuous beep Very low voltage at batteries or charger failure Batteries and charger must be inspected by qualified personnel Intermittent 2 beeps per second UPS overloaded Disc...

Page 18: ...again Battery can be degraded because long lifetime Batteries must be replaced by new batteries Intermittent 1 beep per second FANs blocked or damaged Check FANs and call service support if problem c...

Page 19: ...E PRODUCT Conditions Warranty Plus 1 If during the warranty period this product fails to operate under normal use and service due to defects in materials or workmanship authorized distributor or servi...

Page 20: ...9AH x 6 pcs 12V 9Ah x 12 pcs 3 Sealed Lead Acid VRLA AGM 29 PHYSICAL 580 x 438 x 133 mm 3U Power Outlets Total Progr N2 LCD Panel UPS status Load level Battery Input Output voltage Discharge timer an...

Page 21: ...ed to comply with special project requirements N1 Output voltage is selectable from LCD N2 Backup time for programmable outlets is configurable in minutes from LCD to offer longer time to critical loa...

Reviews: