24
INTAB Interface-Teknik AB
4.5
Trig Output
Several "F" loggers can be "synchronised" by interconnecting them via the trig
output.
The trig output goes high reflecting start trig status. It will go low to indicate
that a stop trig condition has occurred.
By connecting this output to the digital trig input of another "F" and using
these properties it is possible to start the recording of two loggers
simultaneously.
Logger 1 will trig Logger 2 as soon as it starts (or stops) storing values.
Logger 2 has to be programmed to start and/or stop on a trig from the digital
trig input.