background image

Page 12

 

Section 10 

-

 Warranty

 

05/20 E&OE

 

Extended Product Warranty

 

 

Intatec Limited (company number 04359938) (

we, us, our

) offers any business customer which 

has purchased directly from us (

Buyer/you

) any of those products which are part of our Hiper 

HIU range of products described in paragraph 2  of Section A  of this extended warranty docu-

ment  (

Hiper  HIU

),  the  benefit  of  an  extended  warranty  in  respect  of  manufacturing  defects, 

subject to the following conditions and exclusions.  

 

 

Section A: Our Warranty

 

1.  Intatec  warrants  to  the  Buyer  that  the  Hiper  HIU  shall  be  free  from  manufacturing  defects 

under normal and proper use (

Warranty

) for a period of 3 years following the Warranty 

 

Commencement Date (as defined in paragraph 5 of this Section A) (

Warranty Period

).

 

 

2. The Warranty only applies to the following products which are part of our Hiper HIU range: 

 

-

 Twin Plate HIU;

 

-

 Single Plate HIU;

 

-

 Cooling Interface Unit;

 

-

 HIU with HW Cylinder arrangement but not including the cylinder. 

 

 

3. Subject always to the warranty exclusions set out in Section B of this extended warranty 

 

document, during the Warranty Period we will repair or replace at our discretion, the Hiper HIU 

or any defective part thereof, which is proven to be a component failure caused by 

 

manufacturing defects.  

 

 

4. The Hiper HIU must be  correctly  installed and commissioned  by a competent and qualified 

installer  and  in  accordance  with  the  installation  manual  to  which  this  extended  warranty 

document  is  enclosed  (which  includes  the  requirement  for  you  to  issue  to  us  (or  procure  the 

issue  of),  those  commissioning  documents  requested  by  us  from  time  to  time  such  as  the 

Benchmark

’ 

commissioning checklist), otherwise the Warranty may not apply. Proof of installa-

tion  and  commissioning  in  accordance  with  this  paragraph  4  may  be  required  to  validate  the 

Warranty. 

 

 

5. The Warranty must be registered by you (or on your behalf) via the internet at 

https://

www.intatec.co.uk/register_hiu_product

 or by post to Intatec Limited, Airfield Industrial Estate, 

Hixon ST18 0PF, no later than 30 days following the Hiper HIU being installed at the relevant 

property, with the date of installation being the 

Warranty Commencement Date

’ 

for the 

purposes of the Warranty. In the event that you fail to register the Warranty in accordance with 

this paragraph 5, then the Warranty Commencement Date shall be deemed to be the date that 

we dispatch the Hiper HIU to you. 

 

 

6. The Warranty only relates to the Hiper HIU and integrated controls and does not extend to 

any connected system or accessories including without limitation any external pumps, external 

wiring, filters and valves. 

 

 

7. The Warranty only extends to the Buyer and the Buyer shall not assign or transfer its rights or 

obligations under the Warranty without our prior written consent. However, nothing in this 

paragraph shall prevent the Buyer

s customers and/or the end

-

users of the Hiper HIU from 

contacting us in accordance with paragraph 1 of Section C. 

 

 

8. The Warranty is not insurance backed. 

 

Section B: Warranty Exclusions and Our Liability

 

 

1. The Warranty shall not apply and we shall not be liable where:

 

a)

 

any alterations or adjustments have been made to the Hiper HIU (including without limitation 
alterations or amendments to its design and/or construction);

 

b)

 

further use is made of the Hiper HIU after we have been notified of an alleged defect:

 

c)

 

repairs have been attempted by anyone other than us or our authorised representatives; the 
Hiper HIU has been moved from its original place of installation; 

 

d)

 

defects are caused by:

 

i.

 

wilful damage, neglect, negligence or abnormal storage or working conditions;

 

ii.

 

accidental or malicious damage (e.g. vandalism) or events outside of our control (e.g. fire, flood 
or explosion);

 

iii.

 

theft or attempted theft;

 

iv.

 

fair wear and tear; 

 

v.

 

a failure to adhere to installation, usage, maintenance and/or servicing instructions  provided 
(orally  or  in  writing)  by  us  from  time  to  time,  including,  without  limitation,  the  installation 
manual issued to you and available via our website at 

www.intatec.co.uk

;

 

vi.

 

incorrect or improper installation, fitting or use of the Hiper HIU (including without limitation 
where  damage  is  caused  to  the  controller  of  the  Hiper  HIU  by  connecting  voltage  to          
connections that are in the installation manual advised as being 

Volt Free

”);

 

vii.

 

use of non

-

genuine spare parts (which have not been approved by us in advance in writing) in 

the installation, maintenance, service or repair of the Hiper HIU; 

 

viii.

 

any problems or defects caused by the supply of services (such as electricity, gas or water) to 
the property where the Hiper HIU is installed;

 

ix.

 

any fault or failure in the systems to which the Hiper HIU is connected (e.g. pumps and boilers); 

 

x.

 

any damage caused by the condition of water which supplies the systems (including without 
limitation hard water scale deposits or sludge resulting from corrosion). 

 

2. The Warranty only applies to any Hiper HIU bought in and installed and used in the United 
Kingdom and Republic of Ireland.  

 

 

3. Except as provided in this extended warranty document and our Standard Terms and 

 

Conditions of Sale (which can  be found online at 

www.intatec.co.uk

), which form the  basis of 

the contract between you and us, we shall have no liability to you in respect of any defect in the 
Hiper HIU supplied.

 

 

4. The terms implied by sections 13 to 15 of the Sale of Goods Act 1979 are, to the fullest extent 
permitted by law, hereby excluded.

 

 

5. We shall in no circumstances be liable to you in contract, tort (including negligence), breach 
of  statutory  duty,  or  otherwise  for  any  of  the  following  losses  arising  under  or  in  connection 
with the Warranty:

 

a)

 

any indirect, consequential or special losses;

 

b)

 

any loss of profit (whether direct, indirect or consequential); and 

 

c)

 

any loss of sales or business (whether direct, indirect or consequential). 

 

 

6.  Nothing  in  the  Warranty  excludes  or  limits  any  liability  which  cannot  legally  be  limited 
including  liability  for  death  or  personal  injury  caused  by  negligence  or  fraud  or  fraudulent 
misrepresentation. 

 

 

7. The Warranty shall apply to any repaired or replaced Hiper HIU supplied to you by us. For the 
avoidance  of  doubt,  any  repair  or  replacement  carried  out  under  the  terms  of  the  Warranty 
does not extend the Warranty beyond the Warranty Period. 

 

 

Section C: How to Claim 

 

 

1. In the unlikely event that you encounter a problem with the Hiper HIU, you or your customer 
and/or end

-

user should contact us promptly in writing (whether by post or email) or by 

 

telephone,  using the contact details set out below in this Section and  in any event within  10 
days of the defect becoming evident. Any claim made under the terms of the Warranty must be 
made within the Warranty Period. 

 

 

2. Once you or your customer and/or end

-

user have contacted us in accordance with paragraph 

1 above to report a problem, we will contact you or your customer or end

-

user (as the case may 

be)  by  telephone  in  the  first  instance  so  that  we  can  ask  a  series  of  initial  questions  to  get  a 
better understanding of the nature of the problem and provide some initial guidance. If we are 
unable  to  resolve  the  problem  by  telephone  remotely,  we  will  arrange,  at  a  mutually  agreed 
time, for an engineer to visit the site where the Hiper HIU is installed to examine the Hiper HIU. 

 

 

3. Please note, health and safety is of paramount importance to us and if our engineers cannot 
gain safe access to the Hiper HIU or our engineer cannot gain access to the property where the 
Hiper HIU is located, then an abortive charge equal to our 

initial call out charge

’ 

(as referred to 

in paragraph 5 of this Section C) shall apply and shall be payable by you on demand. 

 

 

4. After examination by our engineer, we will arrange to repair or replace any part(s) of the 
Hiper HIU, which are in our opinion a component failure caused by manufacturing defects, free 
of charge. 

 

Important note: We will require you to provide details of the serial number of the Hiper HIU in 
order for us to be able to consider any claim, so please have such details readily available 
upon request. 

 

 

Our contact details:

 

Email: [email protected]

 

Telephone: 01889 272180

 

By Post:

 

F.A.O Technical Department

 

Airfield Industrial Estate

 

Hixon

 

Stafford

 

Staffordshire

 

ST18 0PF

 

5. If, after examination by us, we are of the opinion that the defect(s) is/are not covered by the 
terms of the Warranty, additional call out charges (including without limitation an initial call out 
charge) shall apply. Details of such charges (and our payment terms) are displayed on our 
website at 

www.intatec.co.uk

 

 

Section D: General 

 

1. In the event that we receive any personal information from you, we will only use such per-
sonal  information to administer the Warranty.  We may share such personal  information with 
our engineers in order to conduct any repairs or replacements covered by the Warranty. 

 

We  will  process  such  personal  information  in  accordance  with  our  privacy  policy  (a  copy  of 
which  is  available  on  request  or  can  otherwise  be  found  at 

https://www.intatec.co.uk/

privacy_policy

)

 

 

2. This extended warranty document does not give rise to any rights under the Contracts 

 

(Rights of Third Parties) Act 1999 to enforce any term of the Warranty. 

 

 

3.  If  the  terms  and  conditions  set  out  in  this  extended  warranty  document  have  not  been 
complied with in full, then we reserve the right to declare the Warranty as null and void. 

 

 

4.  Any  words  following  the  terms  including,  include,  in  particular,  for  example  or  any  similar 
expression shall be construed as illustrative and shall not limit the sense of the words, 

 

description, definition, phrase or term preceding those terms. 

 

 

5.  If  any  exclusion  or  limitation  expressly  set  out  in  this  extended  warranty  document  is  or 
becomes invalid, illegal or unenforceable, it shall be deemed deleted, but that shall not affect 
the validity and enforceability of the rest of this extended warranty document. 

 

 

6. The terms of this extended warranty document are subject to the law of England and Wales 

and  the  courts  of  England  and  Wales  shall  have  exclusive  jurisdiction  to  settle  any  dispute  or 
claim arising out of or in connection with this extended warranty document

 

-

V3 DIRECT

 

Summary of Contents for HIPER-V3 DIRECT

Page 1: ...curate Inta cannot accept responsibility should it be found that in any respect the information is inaccurate or incomplete as a result of future developments 05 20 E OE Installation Instructions V3 Single Plate Heat Interface Units Instantaneous hot water and direct Heating V3 DIRECT ...

Page 2: ...mmediate risk of serious damage IMPORTANT information critical to the installation or installer IMPORTANT information critical to the user NOTE useful information regarding the operation or installation of the HIU SECTION 1 Important information and introduction Heat Interface Units HIU deliver heat generated from a centralised heating plant to multiple homes apartments or flats The Inta Hiper V3 ...

Page 3: ...power cut Inlet valve is fail safe and will not allow overheating of the DHW plate or to any UFH low temperature circuits when the electronic control is not functioning Mixing valve basically controls flow temperature of water to the heating or hot water Pump bypass that works automatically if the unit is in heating mode and all circuits are closed Water flow passes through the bypass around the h...

Page 4: ...Section 3 Dimensions 05 20 E OE Page 4 10mm 10mm 300mm 300mm clearances 300mm V3 DIRECT ...

Page 5: ...ax DHWS Flow Ltrs min 18 Min DHWS Pressure bar 1 5 Max Hot water temperature 10 bar Heating Performance At 18l m and ΔT of 15 C kW 15 District Heat Provision Maximum Inlet Temperature ºC 85 Minimum required District flow rate 80 C to provide Hot Water 10 to 50 C at max flow rate l min 9 36 Minimum required District flow rate 70 C to provide Hot Water 10 to 50 C at max flow rate l min 11 98 Maximum...

Page 6: ...s The district and apartment pipework should be connected to the appropriate points labelled on the drawing in Section 3 Dimensions It is advisable to provide means of isolation and disconnection via unions on all connections to the unit to facilitate replacement of the unit if this is ever required Inta only recommend using Inta dedicated connections kits as tabled below You need to ensure that t...

Page 7: ...to the cold water inlet and outlet if being used in accordance with local by laws and connect your hot water distribution pipe to the hot water outlet on the station 5 3 Electrical connections All wiring to the unit must be in accordance with the IEE regulations and any local regulations which apply Note If in any doubt a qualified electrician should be consulted The unit is supplied with a 2m 3 c...

Page 8: ...supply connection 1 2 M F COLD water OUT supply OPTION 1 2 M G HOT Water OUT DHWS 1 2 M 1 Electronic Controller TH860001 2 Solenoid Zone Valve TH920003 3 Mixing Valve Stepper Motor TH960001 4 Diverter Valve Stepper Motor TH960001 5 CH Temperature Sensor TH980001 6 CH Safety Cut Out Klixon EL800026 7 DHW Temperature Sensor TH980001 8 Water Meter TBA 9 Heat Exchanger 40 Plate HE884098 10 Drain Valve...

Page 9: ...oor heating mode which comes with a cut out Klixon that will stop the heating from working if the heating flow temperature reaches between 50 C and 55 C If this occurs then the heating will have to be reset on the electronic box before heating mode will operate again see section 8 0 Figure 7 Radiator heating mode 6 3 Hot Water Hot Water has priority unless remote programmer has been programmed oth...

Page 10: ...lean 5 Verify and record in coming water main pressure and flow rate is within the parameters of the HIU specification 6 Verify and record that any valves in the Central heating circuit are in the correct position These should be as the installation schematic in the M E design 7 Verify and record that all valves from the Cold water mains supply to the HIU are in the correct position 8 Verify and r...

Page 11: ...mbient temperature Verify and record the HIU has entered heating mode Return room thermostat back to original temperature 15 For Underfloor Heating installations verify and record the central heating flow temperatures to the pipes into the floor circuits are as specified by the system designer Adjust accordingly if required and verify and record Return room thermostat back to original temperature ...

Page 12: ...t resolve issue replace solenoid coil No Hot Water or Heating Electronics in Fault Mode Solenoid valve not operating Control Valve not operating or Diverter Valve no operating Pump not operating Hot Water Flow sensor not working Safety klixon switch tripped if fitted District water tempera ture too low Low pressure re fill and it will re set See above Check that 24v is being supplied to either or ...

Page 13: ...ommended that the unit is serviced once every 12 months to maintain its efficiency and longevity 9 1 Servicing the Strainer Part 15 Figure 9 Isolate the unit from district supply Open the screw cap from the strainer and take the filter cartridge out Depending on the condition either clean it or replace it and put the screw cap back on again Note the district water in the strainer could be 85 C V3 ...

Page 14: ...United Kingdom and Republic of Ireland 3 Except as provided in this extended warranty document and our Standard Terms and Conditions of Sale which can be found online at www intatec co uk which form the basis of the contract between you and us we shall have no liability to you in respect of any defect in the Hiper HIU supplied 4 The terms implied by sections 13 to 15 of the Sale of Goods Act 1979 ...

Page 15: ...05 20 E OE V3 DIRECT ...

Reviews: