background image

ENGLISH

 

 

 

Quick Installation Guide 

MRX LAN 

 

 

www.insys-icom.com 

These short operating instructions apply for the following  devices of INSYS  icom:  

 

MRX3 LAN 

 

MRX5 LAN

 

 

www.insys-icom.com/manual 

 

 

It is intended for a quick commissioning  by the operator. Refer to the associated manual for further information. 
This and other associated manuals  can be found on our website in the menu Support and Downloads > 
Documentation. Scan the QR code above or enter the URL into your web browser.

 

 
Tec hnical Data 
The product is only intended for the use within  the permissible  technical limits  specified in the data sheets. These limits  must  be observed. 
 

Operating voltage (redundant) 

12 

V … 24

 V DC (±20%) 

Real-time  clock (RTC) buffer time 

typ. 2 days 

Power consumption 

typ. 2.0 W, max.  3.0 W 
fully equipped: max.  20 W 

Temperature range 

-30 

°C … 70

 °C 

(75 °C extended) 

Level input IN1 

HIGH  level = 2 ... 24 V 
LOW level = 0 ... 1 V  
Contact open condition:  HIGH 

Maximum  permissible  humidity 

95% non-condensing 

Current consumption  input IN1 
at LOW potential 

typ. 0.1 mA  when connecting  to 
GND 

IP rating 

Housing  IP40  

Level input IN2 

HIGH  level = 10  ... 24 V 
LOW level = 0 ... 5 V  
Contact open condition:  LOW 

 

 

Power consumption  input IN2 
at HIGH  potential 

max.  3 mA  at 24 V DC 

 

 

 

Tec hnical Boundaries 
Max. line length  for antennas, power supplies,  serial interfaces, inputs and outputs as well  as other signals:  30 m 
Max. line length  of USB  connection lines: 3 m 
Cable cross-

section: 0.25 … 1.5  (2.5) mm² 

(depending  on terminal  size), flexible  lines  require end sleeves 

Su pport 
If you need further support, please contact your sales partner or INSYS  icom  support. You can contact our support department  via e-mail 
under [email protected]

Defects liability terms 
A use other than the intended use, an ignorance of the safety instructions and the documentation,  the use of insufficiently qualified 
personnel  as well  as unauthorised modifications  exclude the liability  of the manufacturer for damages  resulting from  this. The liability  of the 
manufacturer ceases to exist. 

Int ended Use 
The product may only be used for the purposes specified in  the function overview of the manual.  In addition,  it may  be used f or the 
following  purposes: 

 

Usage and mounting  in an industrial cabinet. 

 

Switching  and data transmission  functions in machines  according to the machine  directive 2006/42/EC. 

 

Usage as data transmission  device, e.g. for a PLC. 

The product may not  be used for the following  purposes and used or operated under the following  conditions: 

 

Use, control, switching  and data transmission  in machines  or systems  in explosive  atmospheres. 

 

Controlling,  switching  and data transmission  of machines,  which  may involve risks  to life and limb  due to their functions or  when  a 
breakdown  occurs. 

 