6
Global Controls
CV Output:
The
CV Output
is the envelope’s control voltage output.
• Output range: 0V - 10V.
Gate/Trig Input:
An envelope signal will output from the
CV Output
when a gate or trigger signal is present at the
Gate/Trig Input
.
• Voltage threshold: 3V.
Gate/Trig Button:
An envelope signal will output from the
CV Output
when the
Gate/Trig Button
is pressed.
• This button will illuminate representing the contour of the generated
envelope signal.
Gate/Trig Toggle:
The
Gate/Trig Toggle
can be set to two different
modes. Their names suggest the optimum control signal, but gates and
triggers can be used effectively in either mode with differing results.
Gate Mode:
• When set to
Gate Mode
and gate signals are received at the
Gate/Trig Input
, all envelope stages will complete as expected.
Attack
and
Decay
will complete their durations while held.
Sustain
defines the voltage level of the envelope for as long as the gate is
held. The
Release
stage activates on the falling edge of the gate and
decays to 0V at its defined duration.
GATE IN
LIN ADSR OUT
LOG/EXPO
ADSR OUT
GATE
TRIG
GATE IN
Summary of Contents for ceis
Page 1: ...c is ADSR User Manual...