6
is over 2 mm, please, contact with seller to calibrate the laser.
Care and cleaning
Please handle measuring instrument with care. Clean with
soft cloth only after any use. If necessary damp cloth with
some water. If instrument is wet clean and dry it carefully.
Pack it up only if it is perfectly dry. Transport in original con-
tainer/case only.
Note: During transport On/Off compensator lock (3) must be
set to position “OFF”. Disregard may lead to damage of com-
pensator.
Specific reasons for erroneous measuring results
•
Measurements through glass or plastic windows;
•
Dirty laser emitting window;
•
After instrument has been dropped or hit. Please
check the accuracy.
•
Large fluctuation of temperature: if instrument will
beused in cold areas after it has been stored in warm
areas (or the other way round) please wait some
minutes before carrying out measurements.
Electromagnetic acceptability (EMC)
•
It cannot be completely excluded that this instru-
ment will disturb other instruments (e.g. navigation
systems);
•
will be disturbed by other instruments (e.g. intensive
electromagnetic radiation nearby industrial facilities or
radio transmitters).
Laser class 2 warning label on the laser instrument
Laser classification
The instrument is a laser class 2 laser product accortding to
DIN IEC 60825-1:2007 and Class II in accordance with CFR
21 § 1040 (FDA). This tool may be used without need for
further protective measures.
Safety instructions
Please follow up instructions given in operators’ manual. Do
not stare into beam. Laser beam can lead to eye injury (even
from greater distances). Do not aim laser beam at persons
or animals.
The laser plane should be set up above eye level of persons.
7
Summary of Contents for REDLINER 2V
Page 1: ...Operating manual Laser level REDLINER 2V WWW INSTRUMAXTOOLS COM...
Page 10: ...INSTRUMAX REDLINER 2V 2V1H1D 635 nm 2 1mW 2 10 3 20 50 Li Ion 3 7 3xAA 1 5 5 8 10 35 1 1 8 10...
Page 11: ...5 1 2 3 4 5 6 7 8 9 5 8 1 2 3 1 11 2 3 1 2 3 3 OFF ON 4 3 5...
Page 12: ...4 3 V 2 6 2 7 3 OFF 1 3 5 180 0 5 0 7 1 2 b1 b2 1 2 5 b1 b2 7 b1 b2 1 2 7 5 2 12...
Page 13: ...5 5 2 5 13 5 2 5 2 10 6...
Page 14: ...3 EMC 2 2 DIN IEC 60825 1 2007 EN60825 1 2007 II CFR 21 1040 FDA 7 14...
Page 15: ...15 1...
Page 16: ...16...