Using KeypadLinc

 

The ON/OFF buttons control the load (the device wired directly to KeypadLinc) as well as any linked responders 

  Tap ON button to turn on the load  

  Tap OFF button to turn off the load  

 

The scene buttons

 

control any responders linked to that particular scene/button. When the LED of a button is lit, its 

scene has been activated. Tap the buttons to toggle the scenes on and off. 

 

 

 

 

 

 

 

 

 

 

 

Quick Start Guide

  

KeypadLinc

 

On/Off Switch (Dual-Band) 

Model: 2487S 

 

Installation 

Note: 

Installation should be performed only by a qualified electrician or 

a homeowner who is familiar and comfortable with electrical circuitry. If 

you have any questions regarding installation, consult an electrician or 

call the INSTEON Support Line at 800-762-7845.

 

1)  At the circuit breaker or fuse panel, disconnect the power for all of 

the circuits in the switch junction box. Verify that the power is off by 

trying to turn on the lights controlled by the switches. 

2)  Remove the wallplate from the switch junction box, and then 

unscrew the switch you are replacing and pull it out from the 

junction box 

3)  Disconnect the wires from the switch you are replacing. If the wires 

cannot be detached by unscrewing them, cut the wires where they 

enter the switch, then strip ½” of insulation off the ends. 

4)  If you are installing KeypadLinc into a standard 2-way circuit 

(where only one switch controls the load), follow the diagram below 

to identify and connect the line, load, neutral and ground wires. 

If the colors of the wires do not match the diagram, be sure you 

have identified the wires correctly before connecting them. 

5)  If you are installing KeypadLinc into a multi-way circuit (where 

more than one switch controls the load), please refer to the manual 

6)  After you have connected all of the wires, ensure that all of the 

wire connectors are firmly attached and that there is no exposed 

copper except for the ground wire 

7)  Orienting KeypadLinc with the Set button on the bottom, gently 

place it into the junction box, and then screw it into place. 

8)  Enable power to the KeypadLinc from the circuit breaker or fuse 

panel 

  KeypadLinc’s ON button will turn on

 

9)  Test that KeypadLinc is working properly by tapping the ON and 

OFF buttons 

10)  Reinstall the wallplate 

Set button (push) 

Air gap (pull) 

Wallplate  

(sold separately) 

On/Off buttons  

(load-controlling) 