Read and understand these instructions before installing and retain them for future reference.

This product is not designed or approved for use on powerlines other than 120VAC, 50Hz or 60Hz, single 

phase. Attempting to use this product on unapproved powerlines may have hazardous consequences.

•  Use only indoors or in outdoor rated box

•  This product may feel warm during operation. The amount of heat generated is within approved limits and 

poses no hazards. To minimize heat buildup, ensure the area surrounding this product is as clear of clutter 

as possible.

•  Each Insteon product is assigned a unique Insteon I.D., which is printed on the product’s label.

•  To reduce the risk of overheating and possible damage to other equipment, do not use this product to 

control loads in excess of the specified maximum(s) or, install in locations with electricity specifications 

which are outside of the product’s specifications. If this device supports dimming, please note that dimming 

an inductive load, such as a fan or transformer, could cause damage to the dimmer, the load bearing 

device, or both. If the manufacturer of the load device does not recommend dimming, use a non-dimming 

Insteon device. USER ASSUMES ALL RISKS ASSOCIATED WITH DIMMING AN INDUCTIVE LOAD. 

This device complies with FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is 

subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device 

must accept any interference, including interference that may cause undesired operation of the device.

Le present appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts 

de licence. L’exploitation est autorise aux deux conditions suivantes: (1) l’appareil ne doit pas produire de 

brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radiolectrique subi, mme si le brouillage est 

susceptible d’en compromettre le fonctionnement.

CAUTION - To reduce the risk of overheating and possible damage to other equipment do not install to control 

a receptacle, a motor-operated appliance, a fluorescent lighting fixture, or a transformer-supplied appliance. 

Gradateurs commandant une lampe a filament de tungstene – afin de reduire le risqué de surchauffe et la 

possibilite d’endommagement a d’autres materiels, ne pas installer pour commader une prise, un appareil a 

moteur, une lampe fluorescente ou un appareil alimente par un transformateur.

Summary of Contents for 2867-222

Page 1: ...Alert Module Owner s Manual Alert Module Owner s Manual ...

Page 2: ...stallation Alert Types 5 Triggering Alert Module from an Insteon Device 6 Local Programming About Local Programming 8 Local Programming Flow Chart 9 Factory Reset Factory Reset 11 Appendix Specifications 13 Troubleshooting 15 Certifications and Warnings 16 Product Warranty 17 ...

Page 3: ...3 Everything you need to quickly get up and running Getting Started Everything you need to quickly get up and running Getting Started ...

Page 4: ... Buttons Device Overview Insteon Alert Module Set Button Alert Speaker Status LED Armed Disarmed Plug Alert Module into an unswitched wall outlet Set Button See sections on Local Programming for set button functions ...

Page 5: ...oud Ringing Loud ringing will sound the moment Alert Module is triggered The loud ringing will persist for 30 seconds unless stopped by disarming Alert Module Alert Types Alert Module features two types of audible alerts Choose the suitable alert when creating a Scene using tap tap linking ...

Page 6: ...rt Module tap the set button until you hear the desired alert tone 2 On your Insteon device press and hold the set button until its LED begins blinking 3 On Alert Module press and hold the set button until you hear a double beep 4 Test Alert Module by triggering your sensor or turning on your Insteon device ...

Page 7: ...7 Use the local programming to link Insteon devices together with the set button Local Programming Use local programming to link Insteon devices together with the set button Local Programming ...

Page 8: ...nk has been removed from another Insteon device or four minutes have elapsed without linking Multi Unlinking Mode Allows the removal of multiple links from the Insteon device The device will stay in unlinking mode for 4 minutes or until the device s set button is tapped To move right press and hold the set button To move down tap the set button Status LED blinks green Status LED double blinks gree...

Page 9: ...me Instant Loud Ringing Tap Tap Tap Tap Tap Tap Press Press Press Press Unlinking Mode Multi Unlinking Mode Select Linking Mode Multi Linking Mode Select Press Tap Tap Press Press Tap Tap Exit Exit Exit Exit Local Programming Flow Chart Press Exit ...

Page 10: ...ill erase all links stored in the device s database as well as any customized properties Factory Reset A factory reset will erase all links stored in the device s database as well as any customized properties Factory Reset ...

Page 11: ...ry Reset 1 Unplug Alert Module from its power outlet 2 Simultaneously press and hold the set button while reconnecting Alert Module to power 3 Continue holding the set button until Alert Module stops beeping 4 When the reset is complete Alert Module will double beep ...

Page 12: ...12 Everything else you might need to know about your Insteon product Appendix Everything else you might need to know about your Insteon product Appendix ...

Page 13: ...udio Alert Beeper Setup Memory Non volatile EEPROM Status LED Red Green LED Insteon Features Insteon Device Category 0x07 Insteon Device Subcategory 0x1A Insteon ID 1 Insteon Links 400 Insteon Messages Repeated Yes Insteon Minimum Receive Level 10 mV Insteon Minimum Transmit Level 3 2 Vpp into 5 Ohms Insteon Powerline Device Yes Insteon Powerline Frequency 131 65 KHz Insteon RF Device Yes Maximum ...

Page 14: ... 26 6mm D Enclosure Material UV stabilized plastic Mounting Ungrounded polarized electrical outlet NEMA 1 15 Operating Environment Indoors Operating Humidity Range 0 85 relative humidity non condensing Operating Temperature Range 32º to 104º F 0º to 40º C Set Button Yes Storage Temperature Range 4º to 158º F 20º to 70º C Weight 3 3 oz Electrical Pass through Outlet No Power Consumption 0 75 Watts ...

Page 15: ...15 Troubleshooting For detailed troubleshooting information visit insteon com support ...

Page 16: ...r of the load device does not recommend dimming use a non dimming Insteon device USER ASSUMES ALL RISKS ASSOCIATED WITH DIMMING AN INDUCTIVE LOAD This device complies with FCC Rules and Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference including interfere...

Page 17: ...nties whether oral or written express or implied including any warranty or merchantability or fitness for a particular purpose Any implied warranty including any warranty of merchantability or fitness for a particular purpose which may not be disclaimed or supplanted as provided above shall be limited to the two year of the express warranty above No other representation or claim of any nature by a...

Reviews: