background image

Page 1 of 2 
Rev. 111908 
 

 

Introduction

 

SwitchLinc 220V provides Indoor and Outdoor control of up to 30 Amp 
220 volt loads. Now  you can automate your pool pumps, electric water 
heaters and large sprinkler pumps – even air conditioning units using the 
affordable and easy to install INSTEON (or even X10) technology. The 
clear cover gives you visible status of your device even without opening 
the cover. 
 

9

 Local 

Control 

9

 

Handy Clear Cover for Visible Status 

9

 Weatherproof 

enclosure 

9

 220V 

INSTEON 

9

 

Up to 30 Amps Inductive Load 

Installation

 

 

Important: 

Installation should be performed only by a qualified electrician or by a homeowner who is familiar and comfortable with electrical circuitry. If there are any 

questions, consult an electrician. For setup questions contact Tech Support at SmartLabs for guidance. Tools required: electrical multi-meter, st Phillips screwdrivers 
and a wire cutter/stripper. An appropriate conduit to house the SwitchLinc 220V’s wires and junction box to connect to your existing wiring are both required, but not supplied. 
Two or more properly installed INSTEON Access Points (#2443) are recommended for every home. You will need to ID all your wires before beginning; for installation tips and 
tricks, see the Smarthome Wiki at 

http://wiki.smarthome.com/index.php?title=Main_Page

.

 

Quick-Start Guide

 

SwitchLinc

TM

 – INSTEON 220V On/Off Switch

 

 
Model: 2494S220 
Remote Control of High Amperage 220 Volt Devices

 

“SwitchLinc 220V” 

 Mounting Tabs 
 (2 each side) 

Set Button

SwitchLinc

Blank 

Plate 

 
 

Local Operation 

Turning the Connected Load On and Off Locally 

  

 

 
To turn the connected load/device on, tap the top of SwitchLinc 
 
 
 
 
 
 
To turn the connected load/device off, tap the bottom of SwitchLinc

 

1) 

Disconnect power at the service panel

 

2) 

Using drywall screws (not supplied), or other suitable mounting hardware, mount the unit 
to a wall, post or other suitable support

 

3) 

Route the 6 wires from SwitchLinc 220V through a suitable conduit connected to a 
junction box

 

4) 

In the junction box connect:, using wire nuts (not included):

 

a. Green ground wire to ground

 

b. White Neutral wire to neutral 
c. Both red wires to load as shown in diagram 
d. Both black line wires to line as shown in diagram 

5) 

Turn power back on at your service panel

 

SwitchLinc should turn on by default 

6) 

Tap the bottom of the switch

 

SwitchLinc should turn off 

 

Required Accessories

 

Depending on your particular application, you will likely need: 
 

o

 

6 Large wire nuts 

o

 

½” Conduit / wire sheathing 

o

 

Suitable junction box for connection to existing wiring 

 

Reviews: