6
Section #3 - Short Cut Icons
Edit Trigger Level
Edit Record Time
Event List
Edit Date and Time
Edit Auto Call Home
Edit User Preferences
Maintenance Menu
Edit Password
Unit Setups
Start Monitoring
Enter/Accept
Owner Information
Instantel Information
Perform Sensor Check
After the unit has been configured press the Start Monitor key to record
an event.
9
Recording Events
Delete Events
12
With the Event List displayed on the Micromate screen, select the event(s)
to be deleted and press the Delete icon.
Select the Event List icon or press the Down arrow key to view the list of
recorded events. Select the desired event from the Event List and either
double tap on the entry or press the right arrow key. Navigate through the
event results using the touch screen or keypad.
10
View Events on the Micromate
Configure the Recording Setups
Preferences
Sensor Check
Measurement Units
Pressure Units
Auto Call Home
Display & Sound
Password
Recording Setup
After the event
Metric
dB
Disabled
Screen Saver 2 min, Beep on
Key Press, Beep when Triggered
Disabled
Active Sensors
Microphone Type
USB Sensors
Record Mode
Record Time
Pre Trigger Length
Sample Rate
Trigger Source
Trigger Level
Notes
Job Number
Monitor Scheduler
Scaled Distance
GPS Location
Auxiliary I/O
Geophone/Microphone
Linear
None Connected
Waveform
Fixed 3 seconds
0.25 seconds
1024 for ISEE (or 2048 for DIN)
Geophone
12.7 mm/s
All text fields blank
Off
Off
Disabled
Edit (00 0.000 N 00 0.000W)
Off
8
The factory default settings are listed below. Change these as required
to match your monitoring needs.
721U0101 Rev 04 Micromate Quick Start Guide
13
Print Events (optional printer required)
To print the events connect the Instantel supported printer to the
(USB) port. The Printer icon will appear. Select the event(s) to be printed
and press the Print icon.
11
Save Events
With the Event List displayed on the Micromate screen, connect a USB
memory stick to the (USB) port. The Save icon will appear at the top
of the screen. Select the event(s) to save and press the Save icon.
Micromate Key Pad
Function Keys
Navigation Keys
Turn display On/Off.
Hold to connect and
disconnect the battery.
Unit Setups
Perform Sensor
Check
Start Monitoring
Cancel
Indicator LEDs
Off - No external power source
connected
- Battery fully charged
Green
- Battery charging
Yellow
- Problem with charge circuit
Red
“Heart Beat" LED will flash slowly when
the battery is connected and the LCD
is off. It will flash faster if the unit is
monitoring and very fast if the unit is
recording an event.
Sensor
Check
Start
Monitor
Cancel
7
Setup
Charging
Status
The Charging Status LED will be:
Use the arrows keys to move through
menu items. The Checkmark is used
to Select, Enter or Accept the current
information.
All manuals and user guides at all-guides.com