Instanta SureFlow Touch WMS6PB Installation And User Instructions Manual Download Page 8

REGULAR DAILY USE

 

 

Switch boiler on and wait for the screen to turn white and show “READY” message

 and dispense button to 

turn red. The water will then be at the correct temperature. (the unit will not dispense until the water has 
reached temperature and button is illuminated) 

 

Dispense water by pressing illuminated push-button.   

 

 

OPTIONAL CUP-SUPPORT BRACKET & SPILL-TRAY KIT 

 

An optional 

CUP-SUPPORT BRACKET & SPILL-TRAY KIT

 for the WMS6PB is available from Instanta Spares 

department (Part No: DBST1/KIT). This support bracket attaches to the underside of the boiler-case allowing 
vessels to be placed onto a spill-tray, located beneath the cup recess. This removes the necessity of holding 
the cup/teapot by hand when filling.

 

 
 

 

FILTER COUNTER 

(Optional if a filter or softener has been fitted):

 

 

If an external filter/softener is fitted to the unit there is an optional filter-counter installed in the software. 
This counter measures the water passing through the boiler and reminds the customer (via the display screen) 
to change the filter when required. 

Note: This counter is 

set to ‘Off’ as standard.

 

 

To enable filter-counter, proceed as follows: 

 

-

 

Turn machine off on front panel.  

-

 

Press & hold “on/off” button (for approximately 12 seconds) until red screen shows “PR” in 

centre of 

screen, then release button. Temperature setting is displayed.    

-

 

Press & hold button (long push) for approximately 5 seconds until screen  changes to 

show “empty 

filter symbol

” (default filter setting).

 

-

 

Press button (short push) to scroll between the different filter settings; 

SOFT (13001 litres) 
MEDIUM (9001 litres) 
HARD (6001 litres) 
EMPTY FILTER SYMBOL (No Filter counter) 

-

 

With the required filter setting selected, Press & hold button (long push) for 4 seconds to save. 

-

 

Press & hold button (long push) for approximately 6 seconds until display goes blank. 

-

 

Turn machine back on again. 

-

 

TO RE-SET & CONFIRM NEW SETTINGS; 

…P

ress & hold button, screen will go blank but continue to 

hold, until “READY” message is displayed on a red screen. 

 

-

 

The unit can then be switched back on and used.      

 

If in doubt as to the hardness of water supplied in your area, consult your local water authority 

 
 

PREVENTATIVE MAINTENANCE: 

 

AQ35/KIT 

 The Instanta AQ35 high-flow multi-filter delivers the best quality of water by removing sediment 

and impurities such as chlorine. The filter also reduces scale build-up which results in lower running costs, 
improved energy efficiency and longer life expectancy. Filter capacity: up to 13,500 litres      

 

Available from Instanta Spares Department: 01704 501114   

 
 
 
 

CLEANING 

 

Clean the external surfaces of the boiler regularly to maintain good hygiene 
Wipe external surfaces of the boiler with a damp cloth. Do not use abrasive materials on the outer surfaces. 

Summary of Contents for SureFlow Touch WMS6PB

Page 1: ...el WMS6PB DB600 W Auto Fill Wall Mount Catering Boiler with Push Button Dispense INSTALLATION AND USER INSTRUCTIONS INSTANTA LIMITED Canning Road Southport Merseyside PR9 7SN Tel 01704 501114 Fax 01704 501115 IB91 ISS 03 ...

Page 2: ...RACKET SPILL TRAY KIT 6 OPTIONAL FILTER MONITOR 5 CLEANING 7 SERVICE WARNINGS FAULT DIAGNOSTICS 7 MAINTENANCE SPARES SERVICE INFORMATION 8 GUARANTEE 8 INTRODUCTION Dear Customer Thank you for purchasing this Instanta product Your new water boiler is designed to give you years of trouble free service provided that the instructions contained in this manual are followed All new series Instanta produc...

Page 3: ...iance by a person responsible for their safety Children should be supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply before servicing The unit must be earthed Keep these instructions in a safe place near the unit for future reference ENVIRONMENTAL Information on Disposal for Users of Waste Electrical Electronic Equipment The crossed out wheeli...

Page 4: ...vided Once the machine is positioned tighten the top screws and insert the bottom screw Do not block ventilation holes in boiler case b ELECTRICAL CONNECTION The circuit should be protected by its own 13amp double pole connection unit with flex outlet to BS5733 alternatively the circuit should have a means of disconnection incorporated in fixed wiring having a contact separation of at least 3mm in...

Page 5: ...lbow facing the wall Push the 15mm cold water supply firmly into the elbow NOTE Water that has been treated by the Reverse Osmosis process can become aggressive due to lack of minerals or Ions and in extreme cases can cause leaching and corrosion of pipes fittings and other metal parts within the appliance If the appliance is being fed by water treated by Reverse Osmosis we strongly recommend that...

Page 6: ...outlet VENT PIPE A small silicone rubber tube connects the tank lid to the back panel Ensure this is connected and hasn t come off in transit and that the outlet fitting in the back panel is not obstructed e FITTING CASE Attach the Earth wire connection to bottom of stainless steel boiler case using M4 screw washer supplied Offer up the case to the wall mounted boiler and plug in the two communica...

Page 7: ...mand default setting to Timed dispense 1 Switch off on front of unit 2 Isolate from mains power supply and wait 10 seconds 3 Switch boiler back on and at the same time press hold the dispense button for 5 seconds Boiler will either start to fill with water or the dispense button will begin to flash depending on water level in tank 4 Hold vessel under dispense outlet 5 Press hold the dispense butto...

Page 8: ... PR in centre of screen then release button Temperature setting is displayed Press hold button long push for approximately 5 seconds until screen changes to show empty filter symbol default filter setting Press button short push to scroll between the different filter settings SOFT 13001 litres MEDIUM 9001 litres HARD 6001 litres EMPTY FILTER SYMBOL No Filter counter With the required filter settin...

Page 9: ...us fault conditions Some of these are less serious and the machine will continue to operate as normal while others are more serious and will disable the unit Before calling for service isolate the machine at the mains supply and then switch back on after 10 minutes If the fault does not clear call technical support for advice SCREEN MESSAGE POSSIBLE CAUSES ACTION R E A D Y CHECK WATER WHITE SCREEN...

Page 10: ...GUARANTEE Your boiler is guaranteed for two years from date of installation Our guarantee includes on site labour and parts for problems caused by fault of manufacture and component failure with the following exclusions 1 Problems caused by hard water and lime scale We regret that we cannot be held responsible for problems caused by hard water 2 Accidental damage misuse or use not in accordance wi...

Reviews: