Environmental (Information
On Disposal For Users Of
Waste Electrical & Electronic
Equipment)
The “crossed out wheelie bin” symbol on
this product means that discarded electrical
and electronic products should not be mixed
with general waste. Disposing of the product
correctly will help to save valuable resources
and prevent any potential negative effects
on human health and the environment which
could otherwise arise from inappropriate waste
handling. For proper treatment, recovery and
recycling of end-of-life products, please contact
your dealer or supplier for further information,
or local authority for details of your nearest
designated collection point.
Delivery Checklist
Before starting installation, check that you have
the following parts;
• Catering Water Boiler
• Drip-tray
• Drip-tray fitting kit
• White water inlet hose (3/4”BSP connection)
• User instructions
Technical Specification
Model
1501F 3001F
Width
mm
252
308
Depth
mm
362
362
Height
mm
610
618
Power Rating
KW
3.0
3.0
Weight (Empty)
KG
13.5
15.5
Weight (Full)
KG
28
36
Water Inlet Pressure: Bar
2 to 7
2 to 7
Installation
The boiler must be installed on a horizontal work
surface with sufficient strength to support its
weight.
Locate in an area where there is adequate space
to use the boiler safely (e.g. free from risk of
congestion and tripping hazards).
Connection to Mains Water Supply:
Connect the WRAS approved water filling hose
(3/4”BSP) to the inlet connection point on the
back of the boiler and the other end to the mains
water supply, via an accessible isolating tap with
a ¾”BSP thread.
IMPORTANT:
If micro-bore pipe is used instead
of the inlet hose supplied, the size must be
minimum OD 3/8”(10mm).
The water supply must have a pressure not
exceeding 7bar (96psi), and no lower than 2bar
(20psi) NOTE: If your water pressure exceeds
7bar, fit a suitable pressure reduction valve.
We regret that Instanta cannot be held
responsible for any machine malfunctions if
the water pressure exceeds that stated. If in
doubt, consult your water supply company.
Electrical Connection:
The boiler must be Earthed.
Your machine is supplied with a standard 13amp
bonded plug with a 13amp fuse.
Overflow:
The drip-tray has a limited capacity and is
designed to handle small spillages and drips.
Wherever possible, we strongly recommend
that it is connected to a permanent waste outlet
using the fitting kit provided.
If preferred, and as an alternative, the overflow
can be connected from the back of the
machine using an optional rear-overflow kit
(Pt. No: ROFK1) available from Instanta Spares
Department (01704 502905).
IMPORTANT:
Whichever overflow connection is
chosen, the diameter of the pipe used must be
no less than 15mm.
Whilst every reasonable precaution is taken
to prevent an overflow, Instanta cannot be
held responsible for any damage caused as a
result of incorrect installation or blockage of
the overflow or failure to direct the overflow
to a safe outlet.