FOR USE BY QUALIFIED SERVICE PERSONNEL ONLY
- 4 -
Operation
1. It is recommended that you review the "How
to Apply Instructions" (in our Product
Information Sheet) before beginning heat
sealing operations.
2. Turn the power on by pressing the
POWER
button on the controller.
3. Set the desired temperature and time.
4. Lift handle so that the upper platen is away
from lower platen.
5. Allow the machine to warm up until the
selected temperature is reached.
6. Set the desired pressure by adjusting the
pressure adjust wheel located on the channel
handle assembly. To reduce pressure, turn
wheel to the right (clockwise).
7. Place the substrate on lower platen.
8.
Position transfer or lettering on substrate.
9. Close machine by pulling handle down into
the closed, operational position.
10. The timer will start automatically and a
buzzer will beep at the end of the time cycle.
11. At the end of the operational cycle, lift the
handle slowly and move upper platen to its
full open position.
Operation Timer/Temperature
Control
Solid State Controller
This controller has three (3) control features:
1. Temperature - Temperature may be set from
225-450
°
F (107-232
°
C).
2. Time - Time may be set from 1 second to 10
minutes.
3. Counter - Cycle counter counts the number
of applications from 1 to 9999 (see
additional Notes - Counter).
Controller Operation
1. If the temperature is not being displayed,
press the
MODE
button until temperature is
displayed.
2. Push and hold
SET
button and
simultaneously push UP (
↑
) or DOWN (
↓
)
arrow buttons to the desired temperature
setting.
3. Press the
MODE
button until time is
displayed.
4. Push and hold
SET
button and
simultaneously push UP (
↑
) or DOWN (
↓
)
arrow buttons to the desired timer setting.