2
INSTALLATION & MANUALS
NS1001 Plus
NS1001 LV Plus
NS1001 HL
NS1001 Plus Zones
NS1001 LV Plus Zones
NS1001 HL Zones
Page 1: ...2 INSTALLATION MANUALS NS1001 Plus NS1001 LV Plus NS1001 HL NS1001 Plus Zones NS1001 LV Plus Zones NS1001 HL Zones ...
Page 2: ...at 8 Before you start 8 Preferred place for your Inspire Thermostat 9 Removal of your old Thermostat 10 Install the wall mount 10 Prepare you new Inspire Thermostat 10 Wiring your Inspire Thermostat 11 Install the Thermostat 12 Using your new Thermostat 12 Basic Functions 13 Adjusting the Temperature 13 Off 13 P1 Profile 1 13 P2 Profile 2 13 On 13 Menu 13 Setting the clock 14 Boost Mode 14 Program...
Page 3: ...ostat consisting of 1 x Room Thermostat 1 x Wall Mount 1 x Wiring Cover 1 x Internet Gateway 1 x Network Cable 1 x Power Supply 2 x AA Batteries 2 x Screws 2 x Wall Plugs What s in the box Inspire Home Automation www insiprehomeautomation co uk Installation User manual 2 ...
Page 4: ...om Thermostat has a connection to the Internet Gateway Low Battery If this icon displays then it is time to replace the batteries Menu Advance Enter the programming menu or activate program advance PLUS unit only Select Boost Multipurpose changes function and cycles menu options Activates the Boost function PLUS unit only Adjustment Keys Multipurpose these are used to adjust the desired temperatur...
Page 5: ... Thermostat and the Gateway are programmed to recognise each other Your new Room Thermostat should already be paired to your gateway at the factory so they should automatically recognise each other and connect Power up the gateway and wait until the Power Light is green Then power up the Room Thermostat Within a few seconds the connection should be established confirmed by the Radio symbol on the ...
Page 6: ...ck of the Gateway The RF Link light will begin to flash Amber Next press and hold M and S simultaneously on the Room thermostat for 5 seconds This will make a connection icon located in the bottom left hand corner flash This icon will stay on permanently once a connection has been established Power Internet RF Status Lights Off Flashing amber Amber Green Power light No power Initialising Ready Int...
Page 7: ...ox 1 Unpack the power supply and plug in the Gateway 2 Use the supplied Ethernet cable and plug it into the back of the Gateway connect the other end to your router 3 For optimal performance ensure that your Gateway box is placed minimum 1m from your router Do not place the Gateway box on top of your router 4 Wait until the power light left hand light is solid green 5 Insert your batteries into th...
Page 8: ... screen 3 Press and hold and for 5 seconds 7 dashes will be displayed followed by an activation code 4 Enter this code into the website Please note This activation code is only valid for 1 hour If it is left longer you will need to obtain another code from the Thermostat Activation code If the code did not show please try the following Ensure the Gateway box lights are displayed as described above...
Page 9: ...it must be installed in accordance to BS 7671 IEE Wiring Regulations or to another equivalent standard Installing your Thermostat Do I need to install my Inspire Thermostat somewhere new We find that most Thermostats are located in rooms that have limited use The position of these Thermostats mean the temperature could be warmer or colder than the homeowners feel If you need to move your existing ...
Page 10: ...ptimum readings place your Inspire Thermostat correctly using the following The homes construction and arrangement may affect the communication so consideration is needed Place your Inspire Thermostat so you can easily access and read the on screen display Install on an interior wall Make sure your Thermostat is away from any drafts Install 1 2m 1 5m from the floor Do not place behind doors or any...
Page 11: ...holes on the wall For reference the holes are 75 5mm apart 3 Drill suitable holes with a 6mm drill bit for supplied wall plugs and insert the wall plugs 4 Screw the wall mount into place Prepare you new Inspire Thermostat Install the wall mount 1 Ensure that your electrical supply is isolated or switched off 2 Remove your old thermostat ensuring you make a note of which wires go to which connectio...
Page 12: ...r guarantee If you are in any doubt whatsoever about the wiring we strongly recommend that you consult a qualified electrician or heating engineer 1 Identify the Live and Switched Live wires 2 Make all wires that are not used for this installation safe 3 Prepare the two wires to be connected by striping 5mm off the wire ends 4 Connect the Live and Switched Live wires to your Inspire Thermostat and...
Page 13: ...e if the Thermostat does not slide easily check the following Securing screws do not protrude into the Thermostat The wiring cover is correctly installed Wall mount screws are the correct size 4 Secure the Thermostat by holding in place and lightly tighten the screws underneath to secure the unit Do not over tighten If you have previously followed the instructions to activate your account then you...
Page 14: ...ween 08 30 and 17 00 22 Degrees between 17 00 and 22 30 15 Degrees between 22 30 and 00 00 P2 Profile 2 Your heating will follow the temperature profile The default is 16 Degrees between 00 00 and 07 00 20 Degrees between 07 00 and 23 00 16 Degrees between 23 00 and 00 00 On Your heating will be switched on Menu The Menu button is used to set the clock However if you have an Internet connection th...
Page 15: ...tivate it on our website in the Setup section within your account Once activated the boost function is enabled by pressing and holding the button for 3 seconds The ON will flash to show that boost is currently active and it will switch your heating on for the programmed length of time at the programmed Boost Temperature If set After this time has expired the Thermostat will return to the previous ...
Page 16: ...ional units section and click Add Device You can also name your units within this section Room Thermostat Thermostat Power Supply 2x AA batteries Output 2 wire Volt Free Switch Switch Rating Max 240v ac 5A Controllable Temperature Range 10 30C Frost Protection 5C Radio Frequency 2 4 GHz Dimensions 119 x 88 x 22 mm Gateway Power input 5V 1A Internet Connection Wired Ethernet Cable Radio Frequency 2...
Page 17: ...lay click on Ensure the set temperature is higher than the room temperature then switch the function to ON You should hear an audible click as the Room Thermostat switches on Did you hear the click Yes The thermostat is working correctly With reference to the installation manual check the wiring is secure underneath the wiring cover Also if your boiler has a programmer ensure that the central heat...
Page 18: ...light will periodically change to Amber then back to green Internet Light out No connection to the server This is usually indicative that the gateway does not have a valid internet connection Check that the network cable is securely connected between the gateway and your internet router Check that the router modem is switched on and connected to your phone line Internet connection point Can other ...
Page 19: ... All Variants Is in conformity with the applicable requirements of the following documents Ref No Title Edition date BS EN 61000 6 1 Electromagnetic compatibility EMC Generic 2007 standards Immunity for residential commercial and light industrial environments BS EN 60730 1 Automatic electrical controls for household and 2011 similar use General requirements I hereby declare that the equipment name...